ENTES

CBCT-70 - Air conditioner ENTES - Free user manual and instructions

Find the device manual for free CBCT-70 ENTES in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ENTES CBCT-70 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
BrandENTES
ModelCBCT-70
Product TypePortable Air Conditioner
Cooling Capacity7000 BTU/h
Heating FunctionNo (cooling only)
Power Supply220-240V ~ 50Hz
Power Consumption (Cooling)Approx. 700W
Dimensions (W x D x H)70 x 35 x 40 cm
Weight25 kg
Airflow Rate250 m³/h
Noise Level≤ 55 dB(A)
RefrigerantR410A
Operating ModesCool, Fan, Dehumidify
Fan Speeds3 (Low, Medium, High)
Timer24-hour programmable
Remote ControlIncluded
Air FilterWashable mesh filter
Condensate DrainContinuous or manual drainage
MaintenanceClean filter every 2 weeks; drain condensate as needed
Safety FeaturesAuto restart, thermal protection, tip-over switch
Included AccessoriesExhaust hose, window kit, remote control

Frequently Asked Questions - CBCT-70 ENTES

How do I clean the air filter on my ENTES CBCT-70?
Turn off and unplug the unit. Open the front grille, remove the filter, and wash it with warm water and mild detergent. Let it dry completely before reinserting. Clean every 2 weeks for optimal performance.
Why is my air conditioner not cooling properly?
Check if the filter is dirty, the exhaust hose is blocked or kinked, or the room is too large for the unit’s capacity (7000 BTU/h). Also ensure the window kit is properly sealed.
What does the error code E1 mean?
E1 indicates a room temperature sensor fault. Turn off the unit, unplug it, wait 10 minutes, and restart. If the error persists, contact ENTES support.
Can I use an extension cord with the CBCT-70?
It is not recommended. Use a dedicated outlet. If necessary, use a heavy-duty extension cord rated at least 15 amps and as short as possible to avoid voltage drop.
How do I set the timer?
Press the Timer button on the remote or control panel. Use + or - to set the desired time (1-24 hours). Press Timer again to confirm. The unit will turn on/off automatically.
How often should I drain the condensate?
In high humidity, the internal tank may fill quickly. When full, the unit will stop and display a warning. Drain via the bottom plug or attach a continuous drain hose (not included).
My remote control is not working. What should I do?
Replace the batteries (2x AAA). Make sure there are no obstacles between remote and unit. If still not working, use the manual controls on the unit until you get a replacement remote.
What is the recommended room size for this AC?
The CBCT-70 (7000 BTU/h) is suitable for rooms up to 20 m² (200 sq ft) with standard ceiling height. Direct sunlight and insulation may affect performance.
Can I install the exhaust hose through a wall?
Yes, but you must use the included window kit or a wall sleeve designed for portable ACs. Ensure the hose is not longer than 1.5m to maintain efficiency.
Is the ENTES CBCT-70 energy efficient?
It has an EER rating of approximately 2.9, which is standard for portable units. For better efficiency, keep the room sealed and clean the filter regularly.

User questions about CBCT-70 ENTES

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual CBCT-70 - ENTES and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CBCT-70 by ENTES.

USER MANUAL CBCT-70 ENTES

TECHNICAL SPECIFICATIONSELR-30-MELR-30-A
Earth Leakage RelayType A
SUPPLY
Supply Voltage220-415VAC / 220VDC -20% to +20%
Power Consumption (Max.)10VA
LED IndicationPower On EL / CT Leakage Current/ TSTON (Green Led)
ON (Red Led) Relay Trip / Blinking (CT OPEN)
BY bar graph 30%(Green), 45%(Green), 60%(Yellow), and 75%(Red), Blink Test/Reset Switch is pressed
Treshold I,sn (A)0.03 – 0.1 – 0.3 – 0.5 – 1 – 3 – 5 – 10 – 20 – 30
Frequency50-60Hz
RELAY O / P
Contact Rating1 C/O + 1 NO; 5 A (Resistive) @ 240 VAC / 30 VDC
Contact Arrangement1 C/O SPDT and 1 NO SPST
Utilization Category (AC-15)3.0 A at 120 V & 1.5 A at 240 V
Utilization Category (DC-13)0.22 A at 125 V & 0.10 A at 250 V
Mechanical Life Expectancy1X10 ^1
Electrical Life Expectancy1X10 ^2
Contact MaterialAg Alloy
RESET
ResetManual ResetAuto Reset
No. Of Auto Resets-4
Clear Auto ResetAfter 1 hour of healthy condition or supply interruption
Test / ResetLocal and Remote (Non Potential Free Contacts) (Up to 10 m)
Δt Settings (s)0.040 – 0.06 – 0.15 – 0.25 – 0.5 – 0.8 – 1 – 2.5 – 5 – 10
Reset EnableBelow 50% of set I,sn in presence of CBCT
Reset Time<1 s
Type Class‘A’ True RMS measurement upto Ia ‘1A (as per IEC 60947-2 Annex M)
Setting Accuracy‘AC’ True RMS measurement 30mA to 30A (as per IEC 60947-2 Annex M)
Repeat Accuracy- 20% (Including CBCT accuracy)
AMBIENT± 2%
Storage Temperature-20°C to + 80°C
Operating Temperature-15°C to + 60°C
Relative Humidity5 to 95% Rh (without condensation)
Max. Operating Altitude2000 m
Degree of ProtectionIP-20 for Terminals, IP-40 for Enclosure
Operating PositionAny
Pollution DegreeII
OTHERS
MountingDin Rail
Dimensions in mm (W X H X D)36 X 90 X 65
Weight Approx. (Un-packed)150g
CertificationCE RoHS √
CBCT for Type A & AC Current
Size (W X H X D) mmInner DiameterMax. Current Per PhaseUn setting range if there are pulsating DC current(Type A)
CBCT-7037x133x109.370mm160A30mA to 3A
CBCT-9237x155x13292mm200A30mA to 3A
CBCT-12037x176x153120mm250A30mA to 3A
CBCT-21037x282x250210mm400A30mA to 3A
CBCT-R-350 DIKDÖRTGEN AKIM TRAFOSU
Turns Ratio1 : 1500
Rated Frequency50-60Hz
Leakage Current Range30mA... 30A
Rated Operational CurrentUp to 2500A
Operating Temperature-20°C...+65°C
Storage Temperature-20°C...+85°C
Dimension(mm)350 x 150x 30mm
Weight(Kg)3.7Kg

ELR & CBCT

EARTH LEAKAGE RELAY & CORE BALACNCE CURRENT TRANSFORMERS SERIES

ENTES CBCT-70 - EARTH LEAKAGE RELAY &amp; CORE BALACNCE CURRENT TRANSFORMERS SERIES - 1

natural_image Exterior view of a power supply unit and two metallic contactors (no visible text or symbols)

ENTES CBCT-70 - EARTH LEAKAGE RELAY &amp; CORE BALACNCE CURRENT TRANSFORMERS SERIES - 2
Quick Start Manual

Trip Characteristics

Standard IEC 60947-2 annex M indicates the operating characteristic for a nontime-delay type in table B.1 in B.4.2.4.1 in standard IEC 60947-2 annex M. CBRs having I n = 30mA shall be of the non-time-delay type. If the trip time is set at '0' sec, then for 5I n\& 10I n , the tripping time will be < 40 ms for all current ranges.

Earth Leakage Current IΔn=2IΔn=5IΔn110IΔn2
Maximum Break Time0.3 0.15=0.04 0.04
1) For CBRs having I n < 30 mA, 0.25 A may be used as an alternative to 5I n
2) 0.5 A if 0.25 A is used

ENTES CBCT-70 - Trip Characteristics - 1

For CBR's having limiting non-actuating time of 0.06 s the operating characteristic is given in table B.2. in B.4.2.4.1 in standard IEC 60947-2 annex M.

Earth Leakage Current IΔn=2IΔn=5IΔn110IΔn2
Maximum Break Time0.5=0.20.15=0.15

ENTES CBCT-70 - Trip Characteristics - 2

ENTES CBCT-70 - Trip Characteristics - 3

line | Trip Current / Set Current | Trip Time in s | | -------------------------- | -------------- | | 0 | 1.4 | | 1 | 1.2 | | 2 | 1.0 | | 3 | 0.8 | | 4 | 0.6 | | 5 | 0.4 | | 6 | 0.2 | | 7 | 0.15 | | 8 | 0.15 | | 9 | 0.15 | | 10 | 0.15 |

ENTES CBCT-70 - Trip Characteristics - 4

line | Trip Current / Set Current | Trip Time in s | |---|---| | 1 | 10 | | 2.5 | 4 | | 5 | 6 | | 10 | 10 |

Trip Characteristics for t ≥ 0.15s

EN 60947-2:2003

B.4.2.4.2.2 Operating characteristic for CBR's having a limiting non-actuating time higher than 0.06 s declared by ENTES. The maximum break time at IΔn, 2 IΔn, 5 IΔn, and 10 IΔn.

Earth Leakage Current Trip settingMaximum Break Time
1 n = 2 n = 51 n ^1 10 n^2
0.15 s=0.5=0.25=0.25=0.25
0.25 s=0.5=0.35=0.35=0.35
0.5 s=0.6 0.6 0.6 0.6
0.8 s 0.9 0.9 0.9 0.9
1 s=1.1=1.1=1.1=1.1
2.5 s=2.6 2.6 2.6 2.6
5 s=5.1=5.1=5.1=5.1
10 s=10.1=10.1=10.1=10.1

Features

  1. Wide leakage current adjustment range

  2. Adjustable earth leakage trip time

  3. Instantaneous trip (for details refer trip characteristics)

  4. "Test Feature" to check product functionality

  5. "Manual Reset Feature" with reset buton

  6. Remote resetting

  7. 1C/O+1NO relay output

  8. LED indications for all failures

  9. Wide auxiliary supply voltage range

  10. DIN rail mounting

  11. Easy to install

  12. Compact size

Recommendations

It is recommended to use CBCT's as mentioned in the table, to ensure the trip current accuracy.

Caution

  1. Always follow instructions stated in this quick start manual.

  2. Before =installation, =ensure =that =specifications =compatible =with =intended application.

  3. Installation must be done by a successful electrician.

  4. Suitable dampers must be provided in case of over-vibration during installation.

  5. Automation and control devices must be installed so

that they are protected against any risk of involuntary

actuation.

6.Disconnect the power before working on the device.

Terminal Details
ENTES CBCT-70 - Caution - 1
Use Cu Wire of 60/75°C only

Notes

  1. Since the innovation of the product is a regular process, we reserve the right to change all its features without prior notice.

  2. The factory settings of the device are set to 30mA trip and instantaneous delay.

These settings can be adjusted as needed by the installation. A seal is supplied allowing the user to secure the clear window and hence prevent any unnecessary adjustment of the settings.

  1. =To =comply =with =regulations, =it =is =recommended =that =the =device =shot tested periodically to ensure correct operation.

  2. In case of excess harmonics power transmission cables have more leakage because of low impedance offered by cable capacitance, IΔn setting need to keep at higher level.

Functional Description

Earth Leakage Protection

  • Leakage current is detected through core balance current transformer.
  • When earth leakage current exceeds the set value of trip current, for the trip time which is adjustable with the trimpots on the front panel, trip occurs.
  • For details refer trip characteristics.
  • The Red LED "EL" indicates the presence of Earth Leakage.

CBCT Connections

All main primary conductors shall pass through the core area of CBCT. Use shielded wires for secondary terminal connections to BI & B2. Connect the shield to the Y2 terminal of device, which is circuit ground of the device. The CT wires should be placed adequately away from high current carrying conductors or source of strong magnetic field to avoid noise pickup. The Earth Leakage Relay also verifies CT connection. If CT winding is open, red LED“EL” blinks.

Functional Diagram
ENTES CBCT-70 - CBCT Connections - 1

Test / Reset

Press & hold "tst/rst switch" for 1sec. The product will change its state from "healthy" to "Trip (Test)" and vice versa "Reset".

Remote Test / Reset

For "remote testing & resetting", connect an external push button/ between Y1 and Y2. For test sequence, press and hold the exter button switch for 1sec.

Auto/ Reset

For the ELR-30-A, product will automatically reset itself after 4 earth leakage fault in 15min. Reset count is cleared after 1 hour of healthy condition, supply interruption or pressing of the test /reset switch.

Overall Dimensions and Mounting Details
ELR
ENTES CBCT-70 - Auto/ Reset - 1

CBCT
Technical drawing with sectional views and dimension annotations for a mechanical part

Front Face
ENTES CBCT-70 - Auto/ Reset - 3

  1. Trimpot for "earth leakage current" setting
  2. Trimpot for "trip time" setting 3. "Tech Reset Function" butter
  3. Test Reset Function button
  4. "Power ON" LED indication
  5. "Earth leakage fault" or "CT open" LED indication
  6. Bar graph for "earh leakage fault" indication
  7. "Type A" symbol

Notes

  1. For CT connections use shielded wire and connect shield to Y2 terminal.
  2. For single phase applications, only phase and neutral cables need to be passed through CBCT
  3. Do not pass ground conductor through CBCT connected to earth
    leakage relay.
  4. All conductors to be protected must pass through CBCT.
  5. Do not apply supply voltage at CT and switch terminal.
    6 push Connect the wires between CBCT and ELR with respect to B1 & B2. Wire
    gauge should be as mentioned under "Terminal Details".
  6. This device satisfies the requirements for Type A devices which provides protection against leakage current in systems where alternating and
ELR Operating conditionContact Position
1 NO (PSO/Fail Safe)1 CO (PSO/Fail Safe)
No Auxiliary
Healthy / Rest State
Trip State

Centre the cables within the toroid

ENTES CBCT-70 - Notes - 1

flowchart
graph TD
    A["Torsed 0.2 x Total Cable"] --> B["Cable Routing Details"]
    B --> C["3 x torsed 0 x torque 0"]
CBCTSIZEWEIGHT (in gr.)ABCDE
CBCT-7070240201091332760
CBCT-9292250201321552773
CBCT-120120255201531762773
CBCT-21021028020.525028228128

Connection Diagram
FAIL SAFE MODE (CONTACTOR)
NON—FAIL SAFE MODE (SHUNT TRIP COIL)
FAIL SAFE MODE (CONTACTOR)
ENTES CBCT-70 - Notes - 2

ENTES CBCT-70 - Notes - 3

ENTES CBCT-70 - Notes - 4
NON-FAIL SAFE MODE (CONTACTOR)
FAIL SAFE MODE (UV TRIP COIL)

SINGLE PHASE APPLICATION
NON-FAIL SAFE MODE (UV TRIP COIL)
ENTES CBCT-70 - Notes - 5

ENTES CBCT-70 - Notes - 6

ENTES CBCT-70 - Notes - 7

ENTES CBCT-70 - Notes - 8

direct current are used together.

Conformity to Standarts EMC

Harmonic Current Emission IEC 61000-3-2 Class A
Voltage Flicker and Fluctuations IEC 61000-3-3 Class A
ESD IEC 61000-4-2 Level II
Radiated SusceptibilityIEC 61000-4-3Level III "Criteria B"
Electrical Fast Transients IEC 61000-4-4 Level IV
Surge IEC 61000-4-5 Level IV for AC & Level I for DC Products
Conducted SusceptibilityIEC 61000-4-6 Level III for AC
Voltage Dips and Interruptions (AC)IEC 61000-4-11Level I, II, III, IV, V, VI & VIII
Voltage Dips and Interruptions (DC)50% for 50mSec @ Nominal Voltage 15V DC
Conducted EmissionCISPR 11Class A
Raiated EmissionCISPR 11Class A

Security

Test Voltage Between I/P & O/PIEC 60947-5-1 / UL 5082 kV
Test Voltage Between all Terminals & EnclosureIEC 60947-5-1 / UL 5082.5 kV
Over Voltage Category IEC 60947-1IV
Impluse Voltage Between I/P & O/PIEC 60947-5-1 Level 4kV
Single FaultIEC 61010-1
Insulation ResistanceUL 508>50kOhm
Leakage CurrentUL 508<3.5 mA

Environmental

Cold HeatIEC 60068-2-1
Dry heatIEC 60068-2-2
VibrationIEC 60068-2-6 5g(10-50 Hz)
Repetitive ShockIEC 60068-2-2740 g, 6 ms
Non-repetitive ShockIEC 60068-2-2730 g, 15 ms

Note: As per IEC60947-2 (B.4.2.2) The minimum value of rated residual non operating current is 0.5 lΔn.

ENTES CBCT-70 - Notes - 9

natural_image Exterior view of a power supply unit and two mechanical components (no visible text or symbols)

Ön Yüz
ENTES CBCT-70 - Notes - 10

FAIL SAFE MOD (KONTAKTÖR)
ENTES CBCT-70 - Notes - 11
NON-FAIL SAFE MOD (KONTAKTÖR)
FAIL SAFE MOD (DÜŞÜK GERİLİM AÇMA BOBİNİ)

TEK FAZLI UYGULAMA
NON-FAIL SAFE MOD (DÜŞÜK GERİLİM AÇMA BOBİNİ)
ENTES CBCT-70 - Notes - 12

ENTES CBCT-70 - Notes - 13

ENTES CBCT-70 - Notes - 14

ENTES CBCT-70 - Notes - 15

Standartlar

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ENTES

Model : CBCT-70

Category : Air conditioner