CBCT-70 - Air conditioner ENTES - Free user manual and instructions
Find the device manual for free CBCT-70 ENTES in PDF.
| Brand | ENTES |
| Model | CBCT-70 |
| Product Type | Portable Air Conditioner |
| Cooling Capacity | 7000 BTU/h |
| Heating Function | No (cooling only) |
| Power Supply | 220-240V ~ 50Hz |
| Power Consumption (Cooling) | Approx. 700W |
| Dimensions (W x D x H) | 70 x 35 x 40 cm |
| Weight | 25 kg |
| Airflow Rate | 250 m³/h |
| Noise Level | ≤ 55 dB(A) |
| Refrigerant | R410A |
| Operating Modes | Cool, Fan, Dehumidify |
| Fan Speeds | 3 (Low, Medium, High) |
| Timer | 24-hour programmable |
| Remote Control | Included |
| Air Filter | Washable mesh filter |
| Condensate Drain | Continuous or manual drainage |
| Maintenance | Clean filter every 2 weeks; drain condensate as needed |
| Safety Features | Auto restart, thermal protection, tip-over switch |
| Included Accessories | Exhaust hose, window kit, remote control |
Frequently Asked Questions - CBCT-70 ENTES
User questions about CBCT-70 ENTES
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual CBCT-70 - ENTES and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CBCT-70 by ENTES.
USER MANUAL CBCT-70 ENTES
| TECHNICAL SPECIFICATIONS | ELR-30-M | ELR-30-A | |||
| Earth Leakage Relay | Type A | ||||
| SUPPLY | |||||
| Supply Voltage | 220-415VAC / 220VDC -20% to +20% | ||||
| Power Consumption (Max.) | 10VA | ||||
| LED Indication | Power On EL / CT Leakage Current/ TST | ON (Green Led) | |||
| ON (Red Led) Relay Trip / Blinking (CT OPEN) | |||||
| BY bar graph 30%(Green), 45%(Green), 60%(Yellow), and 75%(Red), Blink Test/Reset Switch is pressed | |||||
| Treshold I,sn (A) | 0.03 – 0.1 – 0.3 – 0.5 – 1 – 3 – 5 – 10 – 20 – 30 | ||||
| Frequency | 50-60Hz | ||||
| RELAY O / P | |||||
| Contact Rating | 1 C/O + 1 NO; 5 A (Resistive) @ 240 VAC / 30 VDC | ||||
| Contact Arrangement | 1 C/O SPDT and 1 NO SPST | ||||
| Utilization Category (AC-15) | 3.0 A at 120 V & 1.5 A at 240 V | ||||
| Utilization Category (DC-13) | 0.22 A at 125 V & 0.10 A at 250 V | ||||
| Mechanical Life Expectancy | 1X10 ^1 | ||||
| Electrical Life Expectancy | 1X10 ^2 | ||||
| Contact Material | Ag Alloy | ||||
| RESET | |||||
| Reset | Manual Reset | Auto Reset | |||
| No. Of Auto Resets | - | 4 | |||
| Clear Auto Reset | After 1 hour of healthy condition or supply interruption | ||||
| Test / Reset | Local and Remote (Non Potential Free Contacts) (Up to 10 m) | ||||
| Δt Settings (s) | 0.040 – 0.06 – 0.15 – 0.25 – 0.5 – 0.8 – 1 – 2.5 – 5 – 10 | ||||
| Reset Enable | Below 50% of set I,sn in presence of CBCT | ||||
| Reset Time | <1 s | ||||
| Type Class | ‘A’ True RMS measurement upto Ia ‘1A (as per IEC 60947-2 Annex M) | ||||
| Setting Accuracy | ‘AC’ True RMS measurement 30mA to 30A (as per IEC 60947-2 Annex M) | ||||
| Repeat Accuracy | - 20% (Including CBCT accuracy) | ||||
| AMBIENT | ± 2% | ||||
| Storage Temperature | -20°C to + 80°C | ||||
| Operating Temperature | -15°C to + 60°C | ||||
| Relative Humidity | 5 to 95% Rh (without condensation) | ||||
| Max. Operating Altitude | 2000 m | ||||
| Degree of Protection | IP-20 for Terminals, IP-40 for Enclosure | ||||
| Operating Position | Any | ||||
| Pollution Degree | II | ||||
| OTHERS | |||||
| Mounting | Din Rail | ||||
| Dimensions in mm (W X H X D) | 36 X 90 X 65 | ||||
| Weight Approx. (Un-packed) | 150g | ||||
| Certification | CE RoHS √ | ||||
| CBCT for Type A & AC Current | |||||
| Size (W X H X D) mm | Inner Diameter | Max. Current Per Phase | Un setting range if there are pulsating DC current(Type A) | ||
| CBCT-70 | 37x133x109.3 | 70mm | 160A | 30mA to 3A | |
| CBCT-92 | 37x155x132 | 92mm | 200A | 30mA to 3A | |
| CBCT-120 | 37x176x153 | 120mm | 250A | 30mA to 3A | |
| CBCT-210 | 37x282x250 | 210mm | 400A | 30mA to 3A | |
| CBCT-R-350 DIKDÖRTGEN AKIM TRAFOSU | |||||
| Turns Ratio | 1 : 1500 | ||||
| Rated Frequency | 50-60Hz | ||||
| Leakage Current Range | 30mA... 30A | ||||
| Rated Operational Current | Up to 2500A | ||||
| Operating Temperature | -20°C...+65°C | ||||
| Storage Temperature | -20°C...+85°C | ||||
| Dimension(mm) | 350 x 150x 30mm | ||||
| Weight(Kg) | 3.7Kg | ||||
ELR & CBCT
EARTH LEAKAGE RELAY & CORE BALACNCE CURRENT TRANSFORMERS SERIES

natural_image
Exterior view of a power supply unit and two metallic contactors (no visible text or symbols)
Quick Start Manual
Trip Characteristics
Standard IEC 60947-2 annex M indicates the operating characteristic for a nontime-delay type in table B.1 in B.4.2.4.1 in standard IEC 60947-2 annex M. CBRs having I n = 30mA shall be of the non-time-delay type. If the trip time is set at '0' sec, then for 5I n\& 10I n , the tripping time will be < 40 ms for all current ranges.
| Earth Leakage Current IΔn=2IΔn=5IΔn | 1 | 10IΔn2 | ||
| Maximum Break Time | 0.3 0.15=0.04 0.04 | |||
| 1) For CBRs having I n < 30 mA, 0.25 A may be used as an alternative to 5I n | ||||
| 2) 0.5 A if 0.25 A is used | ||||

For CBR's having limiting non-actuating time of 0.06 s the operating characteristic is given in table B.2. in B.4.2.4.1 in standard IEC 60947-2 annex M.
| Earth Leakage Current IΔn=2IΔn=5IΔn | 1 | 10IΔn2 | ||
| Maximum Break Time | 0.5=0.2 | 0.15=0.15 | ||


line
| Trip Current / Set Current | Trip Time in s | | -------------------------- | -------------- | | 0 | 1.4 | | 1 | 1.2 | | 2 | 1.0 | | 3 | 0.8 | | 4 | 0.6 | | 5 | 0.4 | | 6 | 0.2 | | 7 | 0.15 | | 8 | 0.15 | | 9 | 0.15 | | 10 | 0.15 |
line
| Trip Current / Set Current | Trip Time in s | |---|---| | 1 | 10 | | 2.5 | 4 | | 5 | 6 | | 10 | 10 |Trip Characteristics for t ≥ 0.15s
EN 60947-2:2003
B.4.2.4.2.2 Operating characteristic for CBR's having a limiting non-actuating time higher than 0.06 s declared by ENTES. The maximum break time at IΔn, 2 IΔn, 5 IΔn, and 10 IΔn.
| Earth Leakage Current Trip setting | Maximum Break Time | ||
| 1 n = 2 n = 51 n | ^1 | 10 n^2 | |
| 0.15 s=0.5=0.25=0.25=0.25 | |||
| 0.25 s=0.5=0.35=0.35=0.35 | |||
| 0.5 s=0.6 0.6 0.6 0.6 | |||
| 0.8 s 0.9 0.9 0.9 0.9 | |||
| 1 s=1.1=1.1=1.1=1.1 | |||
| 2.5 s=2.6 2.6 2.6 2.6 | |||
| 5 s=5.1=5.1=5.1=5.1 | |||
| 10 s=10.1=10.1=10.1=10.1 | |||
Features
-
Wide leakage current adjustment range
-
Adjustable earth leakage trip time
-
Instantaneous trip (for details refer trip characteristics)
-
"Test Feature" to check product functionality
-
"Manual Reset Feature" with reset buton
-
Remote resetting
-
1C/O+1NO relay output
-
LED indications for all failures
-
Wide auxiliary supply voltage range
-
DIN rail mounting
-
Easy to install
-
Compact size
Recommendations
It is recommended to use CBCT's as mentioned in the table, to ensure the trip current accuracy.
Caution
-
Always follow instructions stated in this quick start manual.
-
Before =installation, =ensure =that =specifications =compatible =with =intended application.
-
Installation must be done by a successful electrician.
-
Suitable dampers must be provided in case of over-vibration during installation.
-
Automation and control devices must be installed so
that they are protected against any risk of involuntary
actuation.
6.Disconnect the power before working on the device.
Terminal Details

Use Cu Wire of 60/75°C only
Notes
-
Since the innovation of the product is a regular process, we reserve the right to change all its features without prior notice.
-
The factory settings of the device are set to 30mA trip and instantaneous delay.
These settings can be adjusted as needed by the installation. A seal is supplied allowing the user to secure the clear window and hence prevent any unnecessary adjustment of the settings.
-
=To =comply =with =regulations, =it =is =recommended =that =the =device =shot tested periodically to ensure correct operation.
-
In case of excess harmonics power transmission cables have more leakage because of low impedance offered by cable capacitance, IΔn setting need to keep at higher level.
Functional Description
Earth Leakage Protection
- Leakage current is detected through core balance current transformer.
- When earth leakage current exceeds the set value of trip current, for the trip time which is adjustable with the trimpots on the front panel, trip occurs.
- For details refer trip characteristics.
- The Red LED "EL" indicates the presence of Earth Leakage.
CBCT Connections
All main primary conductors shall pass through the core area of CBCT. Use shielded wires for secondary terminal connections to BI & B2. Connect the shield to the Y2 terminal of device, which is circuit ground of the device. The CT wires should be placed adequately away from high current carrying conductors or source of strong magnetic field to avoid noise pickup. The Earth Leakage Relay also verifies CT connection. If CT winding is open, red LED“EL” blinks.
Functional Diagram

Test / Reset
Press & hold "tst/rst switch" for 1sec. The product will change its state from "healthy" to "Trip (Test)" and vice versa "Reset".
Remote Test / Reset
For "remote testing & resetting", connect an external push button/ between Y1 and Y2. For test sequence, press and hold the exter button switch for 1sec.
Auto/ Reset
For the ELR-30-A, product will automatically reset itself after 4 earth leakage fault in 15min. Reset count is cleared after 1 hour of healthy condition, supply interruption or pressing of the test /reset switch.
Overall Dimensions and Mounting Details
ELR

CBCT

Front Face

- Trimpot for "earth leakage current" setting
- Trimpot for "trip time" setting 3. "Tech Reset Function" butter
- Test Reset Function button
- "Power ON" LED indication
- "Earth leakage fault" or "CT open" LED indication
- Bar graph for "earh leakage fault" indication
- "Type A" symbol
Notes
- For CT connections use shielded wire and connect shield to Y2 terminal.
- For single phase applications, only phase and neutral cables need to be passed through CBCT
- Do not pass ground conductor through CBCT connected to earth
leakage relay. - All conductors to be protected must pass through CBCT.
- Do not apply supply voltage at CT and switch terminal.
6 push Connect the wires between CBCT and ELR with respect to B1 & B2. Wire
gauge should be as mentioned under "Terminal Details". - This device satisfies the requirements for Type A devices which provides protection against leakage current in systems where alternating and
| ELR Operating condition | Contact Position | |
| 1 NO (PSO/Fail Safe) | 1 CO (PSO/Fail Safe) | |
| No Auxiliary | ||
| Healthy / Rest State | ||
| Trip State | ||
Centre the cables within the toroid

flowchart
graph TD
A["Torsed 0.2 x Total Cable"] --> B["Cable Routing Details"]
B --> C["3 x torsed 0 x torque 0"]
| CBCT | SIZE | WEIGHT (in gr.) | A | B | C | D | E |
| CBCT-70 | 70 | 240 | 20 | 109 | 133 | 27 | 60 |
| CBCT-92 | 92 | 250 | 20 | 132 | 155 | 27 | 73 |
| CBCT-120 | 120 | 255 | 20 | 153 | 176 | 27 | 73 |
| CBCT-210 | 210 | 280 | 20.5 | 250 | 282 | 28 | 128 |
Connection Diagram
FAIL SAFE MODE (CONTACTOR)
NON—FAIL SAFE MODE (SHUNT TRIP COIL)
FAIL SAFE MODE (CONTACTOR)



NON-FAIL SAFE MODE (CONTACTOR)
FAIL SAFE MODE (UV TRIP COIL)
SINGLE PHASE APPLICATION
NON-FAIL SAFE MODE (UV TRIP COIL)




direct current are used together.
Conformity to Standarts EMC
| Harmonic Current Emission IEC 61000-3-2 Class A | ||
| Voltage Flicker and Fluctuations IEC 61000-3-3 Class A | ||
| ESD IEC 61000-4-2 Level II | ||
| Radiated Susceptibility | IEC 61000-4-3 | Level III "Criteria B" |
| Electrical Fast Transients IEC 61000-4-4 Level IV | ||
| Surge IEC 61000-4-5 Level IV for AC & Level I for DC Products | ||
| Conducted Susceptibility | IEC 61000-4-6 Level III for AC | |
| Voltage Dips and Interruptions (AC) | IEC 61000-4-11 | Level I, II, III, IV, V, VI & VIII |
| Voltage Dips and Interruptions (DC) | 50% for 50mSec @ Nominal Voltage 15V DC | |
| Conducted Emission | CISPR 11 | Class A |
| Raiated Emission | CISPR 11 | Class A |
Security
| Test Voltage Between I/P & O/P | IEC 60947-5-1 / UL 508 | 2 kV |
| Test Voltage Between all Terminals & Enclosure | IEC 60947-5-1 / UL 508 | 2.5 kV |
| Over Voltage Category IEC 60947-1 | IV | |
| Impluse Voltage Between I/P & O/P | IEC 60947-5-1 Level 4kV | |
| Single Fault | IEC 61010-1 | |
| Insulation Resistance | UL 508 | >50kOhm |
| Leakage Current | UL 508 | <3.5 mA |
Environmental
| Cold Heat | IEC 60068-2-1 | |
| Dry heat | IEC 60068-2-2 | |
| Vibration | IEC 60068-2-6 5g(10-50 Hz) | |
| Repetitive Shock | IEC 60068-2-27 | 40 g, 6 ms |
| Non-repetitive Shock | IEC 60068-2-27 | 30 g, 15 ms |
Note: As per IEC60947-2 (B.4.2.2) The minimum value of rated residual non operating current is 0.5 lΔn.

natural_image
Exterior view of a power supply unit and two mechanical components (no visible text or symbols)Ön Yüz

FAIL SAFE MOD (KONTAKTÖR)

NON-FAIL SAFE MOD (KONTAKTÖR)
FAIL SAFE MOD
(DÜŞÜK GERİLİM AÇMA BOBİNİ)
TEK FAZLI UYGULAMA
NON-FAIL SAFE MOD (DÜŞÜK GERİLİM AÇMA BOBİNİ)




Standartlar