ENTES

CBCT-120 - Uncategorized ENTES - Free user manual and instructions

Find the device manual for free CBCT-120 ENTES in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ENTES CBCT-120 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Type Core Balance Current Transformer (CBCT)
Model CBCT-120
Brand ENTES
Application Earth leakage detection for electrical installations
Rated Primary Current 120 A
Frequency 50/60 Hz
Output Signal Secondary current proportional to earth leakage
Accuracy Class 1 or better
Operating Temperature -25°C to +55°C
Dimensions (approx.) 130 mm x 80 mm x 60 mm
Weight (approx.) 0.5 kg
Enclosure Rating IP20
Standards IEC 62020, IEC 61557
Installation Snap-on mounting on DIN rail or panel
Maintenance Regular visual inspection and functional test
Safety Double insulation, CAT III
Spare Parts Contact ENTES service center

Frequently Asked Questions - CBCT-120 ENTES

What is the purpose of the ENTES CBCT-120?
The CBCT-120 is a core balance current transformer used to detect earth leakage currents in electrical installations, typically for protection relay triggering.
How do I install the CBCT-120?
Mount the CT on a DIN rail or panel. Pass all live conductors (L1, L2, L3, N) through the window. Secure wiring to the secondary terminals.
What is the maximum primary current rating?
The rated primary current is 120 A continuous. Do not exceed this value to avoid saturation or damage.
Can the CBCT-120 be used for three-phase systems?
Yes, it is designed for three-phase and single-phase systems. All phase and neutral conductors must pass through the CT window.
What output does the CBCT-120 provide?
It provides a secondary current that is proportional to the earth leakage current. Typical output is 1 A or 5 A at rated leakage.
How do I test the CBCT-120?
Use a primary injection test set to inject a known leakage current. Measure secondary output and compare with expected ratio.
What is the accuracy class of the CBCT-120?
The accuracy is typically Class 1 per IEC 62020, ensuring reliable earth leakage measurement.
Can the CBCT-120 be used outdoors?
No, it has an IP20 rating, suitable for indoor use only. For outdoor, install in a weatherproof enclosure.
What is the operating temperature range?
The device operates from -25°C to +55°C. Avoid exposure to extreme conditions.
Is the CBCT-120 compatible with any earth leakage relay?
It is compatible with most relays accepting a 1 A or 5 A secondary input. Check relay specifications for burden and ratio.

User questions about CBCT-120 ENTES

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual CBCT-120 - ENTES and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CBCT-120 by ENTES.

USER MANUAL CBCT-120 ENTES

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ENTES

Model : CBCT-120

Category : Uncategorized