HAGER JKD114 - Multimeter

JKD114 - Multimeter HAGER - Free user manual and instructions

Find the device manual for free JKD114 HAGER in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAGER JKD114 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Digital Multimeter
Brand Hager
Model JKD114
Display LCD, 2000 counts
DC Voltage Range 200 mV to 600 V
AC Voltage Range 200 V to 600 V
DC Current Range 200 µA to 10 A
Resistance Range 200 Ω to 2 MΩ
Continuity Test Yes, with buzzer
Diode Test Yes
Safety Rating CAT II 600V
Power Supply 9V battery (6F22)
Dimensions 150 x 70 x 30 mm
Weight 200 g (including battery)
Accessories Included Test leads, battery, user manual
Operating Temperature 0°C to 40°C
Storage Temperature -10°C to 50°C
Overrange Indication Display "OL"
Low Battery Indication Display symbol
Auto Power Off Yes, after 15 minutes
Maintenance Clean with a soft, dry cloth; avoid solvents
Safety Read manual, use proper probes, don't exceed rated voltage
Spare Parts Test leads and battery; internal parts not user-serviceable

Frequently Asked Questions - JKD114 HAGER

How do I measure AC voltage?
Set the rotary switch to the AC voltage range (V~). Connect the test leads to the circuit. Read the value on the LCD. Ensure the voltage does not exceed 600V AC.
How do I test continuity?
Set the rotary switch to the continuity test position (usually denoted by a diode or sound wave symbol). Connect the test leads across the circuit. If the resistance is less than 30Ω, the built-in buzzer will sound.
What does 'OL' on the display mean?
OL stands for Overload. It indicates that the measured value exceeds the selected range. Select a higher range if possible.
How do I replace the battery?
Turn off the meter and disconnect test leads. Remove the battery compartment screw and slide off the cover. Replace the 9V battery (6F22) with a new one, observing polarity. Reattach the cover.
What is the accuracy of this multimeter?
DC voltage accuracy is typically ±0.5% of reading + 2 digits. AC voltage accuracy is ±1.2% of reading + 5 digits. Resistance accuracy is ±0.8% of reading + 4 digits. Refer to manual for full specifications.
Can I measure current above 10A?
No, the maximum current measurement is 10A. Do not attempt to measure currents above this limit to avoid damage or injury.
How do I use the diode test?
Set the rotary switch to the diode test position (diode symbol). Connect the red lead to the anode and black to the cathode. The display shows the forward voltage drop. A good silicon diode reads 0.5-0.8V.
Why does my meter not turn on?
Check if the battery is installed correctly or depleted. Ensure the rotary switch is not in an off position. If the problem persists, replace the battery.
Is this multimeter autoranging?
No, the Hager JKD114 is a manual ranging multimeter. You must select the appropriate range and function using the rotary switch.
What safety precautions should I take?
Always use proper test leads with finger guards. Do not measure voltages above 600V. Never use the meter on circuits with voltage above CAT II rating. Inspect leads for damage before use. Remove leads when changing functions.

User questions about JKD114 HAGER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Multimeter in PDF format for free! Find your manual JKD114 - HAGER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. JKD114 by HAGER.

USER MANUAL JKD114 HAGER

Painted Metal Enclosure

Dimensions(mm)Enclosure Size
81216222x122x162x223x22
A254325398505326398505505
B298236296336472472472708
CN/AN/AN/AN/AN/AN/AN/AN/A
D125125125125125125125125

ZD0851

ZD0651
HAGER JKD114 - 1
GB JKA Boards
Instructions/Data Sheet

This DBO and Hager devices conform with the following standards: Males Dined End EN 50470

Meter Direct Fed EN 30470 RR EN 61499.0 Including A

BS EN 61435-3 including Annex ZB. Switch-disconnectors: BS EN 60947-3.

Residual Current Circuit Breaker IRCCBI: BS EN 61008-1

Residual current operated circuit breaker with integral overload (RCBO): BS EN 61008-1

Miniature Circuit Breaker (MCB): BS EN 60808-1

Installation Instructions:

All product(s) must be installed by a suitably competent electrician giving consideration to their intended use and in accordance with the current edition of BS 7671 (IET Wiring Regulations).

The Electricity at Work regulations and the Health and Safety at Work Act shall be complied with.

Only equipment and arrangements specified in Hager's technical documentation / catalogue shall be used.

Install in the horizontal plane only

Important notes:

To prevent potential overheating from loose connections the installer shall check connections are tight to the torque levels stated in these instructions prior to energizing this board. This check should include factory mode connections which may have loosened in transit.

Tightening torque values to be applied (Nm)
Switch disconnector's 20A & 83A: 2.8 NmSwitch disconnector's 100A: 3.6 NmRCB's 40A & 53A: 2.9 NmRCB's 80A & 100A: 3.5 NmMCBs: 2.8 NmRCSO's: 2.8 NmEarth & Neutral terminal bar connections: 2.0 NmSingle conductors below 1.5mm ^2 need to be doubled back in the terminal barFront metal cover fixing screws: 2.0 NmMetal torque: 2.4 Nm

Good workmanship and proper materials must be applied by the installer. The cable entry method shall, as far as reasonably practical, maintain the non-combustable arrangement of the enclosure. Account shall be taken of these instructions.

HAGER JKD114 - Important notes: - 1

Metalclad units are provided with knockouts for standard 20, 25, and 32mm conduit and large rear knockouts.

HAGER JKD114 - Important notes: - 2

Pull and lift the terminal bar support away from the unit resting the rail supported by the earth strap. After fixing concur/ cable glands, locate the rail support and press down.

ZD0651

Note: Only BASEC approved cable should be used

1.0mm² to 16mm² for outgoing cables

up to 35.0mm² for incoming live cables

Single conductors below 1.5mm² need to be doubled back in the terminal bar.

:hager

JKA Boards Instructions Sheet

:hager

JKA Boards Instructions Sheet

Guidance Notes:

The total load must not exceed the rating of the incoming device or the assigned assembly rating (InA) whichever is the lower. Each neutral and earth connection must correspond numerically to its outgoing way. Additional blanks (ref. JK01B) are available to cover spare ways.

A pack is provided to label this DBO, please consult us for spares or replacements.

Operating Instruction leaflet is provided overleaf. This leaflet should be left for the end user. Single conductor below 1.5mm² need to be doubled back in the terminal bar.

DBOs incorporating RCDs in TT systems should incorporate an S-type (time Delayed) RCCB, e.g. 100 mA s-type RCCB. Alternatively a main switch with RCBO protection on all outgoing circuits should be used.

Precautions need to be taken to prevent faults to earth on the supply side of the RCD (as per BS7671 regulation 531.4.1)

IP Ratings:

Cable access into the DBO must maintain the integrity so far as reasonably predictable. In essence, for surfaces accessible after installation, this means maintaining the requirement for the horizontal top surface of the enclosure to provide a degree of protection of at least IP4X and elsewhere. IP30. For rear cable access, the minimum number of knockout(s) shall be removed.

IP Code Description
IP2XC Protection against access with a tool (2.5mm diameter, 100mm long) making contact with live hazardous ports
IP30 Protection against access with a tool (2.5mm diameter, shall not penetrate)
IP4X. A probe of 1mm diameter shall not enter the enclosure

Fitting Hager MCBs and RCBOs:

Only equipment and arrangements specified in Hager's technical

documentation / catalogue shall be used.

  1. Isolate the electrical supply from the DBO.

  2. Remove the front cover.

  3. Fully slacken the lower terminal of the device.

  4. Fully open the bottom device clip (fig 1.)

HAGER JKD114 - Fitting Hager MCBs and RCBOs: - 1

Warranty

This distribution board is offered with a 24 month warranty against detective material or manufacture. If a warranty claim is necessary, please call the technical support number given at the bottom of the page and we will be pleased to help.

For dimensional information and weights please consult the Hager catalogue.

  1. Locate the device onto the din rail, and busbar. Ensure that the busbar tooth is within the device terminal cage.
  2. Close the bottom device clip.
  3. While holding the device firmly onto the busbar, fully tighten the
    lower terminal screw.
  4. After fitting all outgoing devices and connecting all outgoing cables, please check the tightness of all cable connections. This should include all factory made connections, which may have loosened during installation or transit.

[Non-Text]
active material or manufacture. If a warranty claim is necessary, please we will be pleased to help.

表决结果:

ogue.
[Non-Text]

[Non-Text]
[Non-Text]
[Non-Text]

[Non-Text]

[Non-Text]
[Non-Text]

[Non-Text]

[Non-Text]

[Non-Text]
[Non-Text]
[Non-Text]

[Non-Text]

[Non-Text]
[Non-Text]
[Non-Text]
[Non-Text]

[Non-Text]

Hager Technical Help Line: 01952 675-689

Hager Technical Fax: 01952 675 557

Website: www.hager.co.uk

E-mail us: info@hager.co.uk

Interface characteristics
Rated & operational voltage (Un / Uo)230V a.c. 50Hz
Rated insulation voltage (Ui)320V a.c. 50Hz
Rated Impulse withstand voltage (Uimp)4kV
Rated current of the Assembly (InA)100A, 63ANote: Dependent upon rating of main incoming device
Rated current of an Outgoing circuit (Inc)MCD 6A - ESA (marked rated current on device)RCBO 6A - SGA (marked rated current on device)Rated current of outgoing unit (Inc)RCDB 40A-100A (marked rated current on device)Direct Fed Motor - 100A (marked rated current on device)
Rated conditional short-circuit current of the ASSEMBLY (Icc)Annex ZB: 16 kA rms at 250V, power factor 0.6 with equipment and arrangements specified in Hager's technical documentation / catalogue. (Does not include metered type A distribution boards)JK A Board DBO loc = 10kA, Ipk 17kA
Protection against electric shockConsumer unit shall be installed in an electrical system conforming to the current edition of IEC 60364 / BS 7671
Rated diversity factor (RDF) / Values of assumed loading1way = 1.02way - 3way = 0.84way - 5way = 0.78way - 9way = 0.610way and above = 0.5Note: RDF only applies to continuously and simultaneously loaded circuits.In principle, this means adjacent circuit-breakers having a load 'on' time exceeding 30 minutes or where a load not exceeding 30 minutes has an 'off' time less than the 'on' time, will need to have the rated diversity factor applied as indicated.
Rated frequency (in)50 Hz
Pollution degree2
Types of system earthing for which the ASSEMBLY is designedTNC-S, TN-S when installed in an electrical installation complying with BS 7671Hager recommends for TT systems a 100A type 8 time delayed RCDB or a main switch with RCBO protection only on all outgoing circuits.
Indoor use only
Stationary ASSEMBLY
Degree of protectionIP2XC with door open and full compliment of outgoing devices and or blanks fitted.IP30 with door closed and full compliment of outgoing sockets and or clarves fitted.Note: Where cables are installed through top wall of enclosure, gaps of IP4X to be maintained.
Intended use
Intended for use in domestic (residential) or similar premises.
Electromagnetic compatibility (EMC) classificationEMC Environment B
External designJKA: Wall-mounted, surface type, enclosed assembly.
Mechanical Impact protectionIK 05
The type of constructionFixed parts
Type A DBO (Distribution board for use by ordinary persons)
Manual assistant