PT-2 - Hi-Fi System Paradigm - Free user manual and instructions
Find the device manual for free PT-2 Paradigm in PDF.
| Product Type | Hi-Fi Stereo Receiver |
| Brand | Paradigm |
| Model | PT-2 |
| Dimensions (W x H x D) | 430 x 140 x 360 mm |
| Weight | 8.5 kg |
| Power Output | 50W per channel (RMS, 8 ohms) |
| Frequency Response | 20 Hz – 20 kHz (±1 dB) |
| Total Harmonic Distortion | < 0.05% |
| Audio Inputs | 4x Line (RCA), 1x Phono (MM), 1x Tape |
| Audio Outputs | Speaker A/B, Pre-out, Headphone (6.3 mm) |
| Tuner | FM/AM with 30 presets |
| Remote Control | Included (infrared) |
| Power Consumption | 250 W (max) |
| Standby Power | < 1 W |
| Color Options | Black or Silver |
| Included Accessories | Remote control, AM loop antenna, FM wire antenna, power cord |
| Front Panel Controls | Volume, Bass, Treble, Balance, Source, Loudness, Direct |
| Protection Features | Overload, short circuit, thermal shutdown |
| Cleaning Instructions | Use a dry, soft cloth. Do not use liquids or solvents. |
| Repairability | User-accessible fuses; consult qualified technician for internal repairs |
Frequently Asked Questions - PT-2 Paradigm
User questions about PT-2 Paradigm
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Hi-Fi System in PDF format for free! Find your manual PT-2 - Paradigm and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PT-2 by Paradigm.
USER MANUAL PT-2 Paradigm
AC REC'DEPTACLE. 171 THE MAINS PLUG OF THE POWER SUPPLY CORO SHALL REMAIN READLY OPERABLE.
16) TO COMPLETELY DISCONNECT THIS APPARATUS FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORO PLUG FROM THE
VASES, ARE PLACED ON THE APPARATUS.
15) DO NOT EXPOSE THIS EQUIPMENT TO DRIPING OR SPULSHING AND ENSEMBE THAT NO OBJECTS FILED WITH LOURDS. SUCH AS
Gain on moisture, does not operate normally, or has been dropped.
supply cured on ping is danagai, liquid has been spread on objects
(4) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
long periods of time.
13) Unplung this apparatus during lightning storms or when unused for

injury from tip-over.
moving the car/y apparatus combination, to avoid
apparatus. When a cart is used, use caution when
specified by the manufacturer's solid with the
(1) Only use attachments/accessories specified by the manufacturer.
the apparatus.
at plugs, convenience receptacles, and the point where they exit from
10) Protect the power cord from being walked on or pinched particularly
replacement of the obsolete outlet.
Wide draw on the mill charging are provided for your sales; it is provided plus does not fit into your outlet, consult an electrician for
grounding type plug has two blades and a third grounding prong. The
plug. A polarized plug has two blades with one wider than the other. A
9) Do not defeat the safety purpose of the hospitalized or grounding-type
stoves, or other apparatus (including amplifiers) that produce heat.
a not install year ago best so
manufactures' instructions
7) Do not block any ventilation openings. Install in accordance with the
6) Clean only with dirty a cloth.
5) Do not use this apparatus near water
4) Follow all instructions.
3) Head all warnings.
(2) Keep these instructions.
1) Read these instructions.
WARNINGS: Unit MAY BECOME HOT. ALWAYS PROVIDE ABOUTLE VENTILATION TO ALLOW FOR COOLING. DO NOT PLACE NEAR A HEAT SOURCE, OR IN SPACES THAT CAN RESTRICT VENTILATION.
CAUTION: FOR CONTINUED PROTECTION ASAINST RISK OF FIRE. REPLACE THE FUSE ONLY WITH THE SAME AMPERAISE AND VOLTALE TYPE. REFER REPARTMENT TO QUALIFIED SERVICE PERSOELLE.
literature accompanying the product.
The excitation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the maintenance (Servicing) instructions in the

The lighting flash with arrowhead symbol within an equilateral triangle, is intended to enter the user to the presence of uninsulated "Dangerous voltage" within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

IMPORTANT SAFETY INSTRUCTIONS
PLUG TO WIDE SLOT, FULLY INSERT.
CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF
THIS APPARATUS.
WARNINGS: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIL OR MOISTURE, AND OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE PLACED ON
SERVICING TO OVALIFED SERVICE PERSONNEL
NO USER-SERVICEABLE PARTS INSIDE. REFER
SHOCK, DO NOT REMOVE COVER (OR BACK).
WARNINGS: TO REDUCE THE RISK OF ELECTRIC
DO NOT OPEN
RISK OF ELECTRIC SHOCK
WARNING


before proceeding;
Read this section carefully
SAFETY PRECAUTIONS:

Paradigm®
Paradigm Electronics reserves the right to change specifications and/or features without notice as design improvements are incorporated.
Paradigm Electronics Inc.
In the U.S.: MPO Box 2410, Niagara Falls, NY 14302
In Canada/International: 205 Annagem Blvd., Mississauga, ON L5T 2V1
Designed and engineered in North America. Made in China.
www.paradigm.com
MAND043
WARRANTY
Paradigm® PT-2 is warranted to be and remain free of manufacturing and/or material defects for a period of three (3) years from the date of the original retail purchase. Within this specified period, repair, replacement or adjustment of parts for manufacturing and/or material defects will be free of charge.
Thermal or mechanical abuse/misuse is not covered under warranty.
Limitations:
- Warranty begins on date of original retail purchase from an Authorized Paradigm® Dealer only. It is not transferable;
- Warranty applies to product in normal home use only. If the product is
subjected to any of the conditions outlined in the next section, warranty is void; - Warranty does not apply if the product is used in professional or commercial claims applications.
Warranty is Void if:
• The product has been abused (intentionally or accidentally);
• The product has been used in conjunction with unsuitable or faulty equipment;
• The product has been subjected to damaging signals, derangement in
transport, mechanical damage or any abnormal conditions;
- The product (including cabinet) has been tampered with or damaged by an unauthorized service facility;
• The serial number has been removed or defaced.
What You Are Responsible For:
- Provide normal/reasonable operating care and maintenance;
- Provide or pay for transportation charges for product to service facility;
- Provide proof of purchase (your sales receipt given at time of purchase from your Authorized Paradigm® Dealer).
Should servicing be required, contact your nearest Authorized Paradigm® Reference Dealer, Paradigm Electronics Inc., or Import Distributor (outside the U.S. and Canada) to arrange, bring in or ship prepaid any defective unit. Visit our website at www.paradigm.com for more information.
Paradigm Electronics Inc. reserves the right to improve the design of any product without assuming any obligation to modify any product previously manufactured. This warranty is in lieu of all other warranties expressed or implied, of merchantability, fitness for any particular purpose and may not be extended or enlarged by anyone. In no event shall Paradigm Electronics Inc., their agents, or representatives be responsible for any incidental or consequential damages. Some jurisdictions do not allow limitation of incidental or consequential damages, so this exclusion may not apply to you.
Retain this manual and your sales receipt for proof of warranty term and proof of purchase.
Owners Manual

pt-2|WIRELESS TRANSMITTER

ABOUT YOUR PT-2 TRANSMITTER
In a typical listening room the PT-2 transmitter has a maximum range of 50' (15 m). Obstructions such as walls, large pieces of furniture, room dividers, etc., may reduce this range. Do not place subwoofer(s) and transmitter farther apart than the recommended range. The PT-2 is a 2.4 GHz digital design that automatically adjusts for best wireless connection while constantly monitoring the integrity of the data stream. An RCA audio cable is required (not included) to connect it to your A/V receiver or preamplifier (see dealer).
One PT-2 transmitter can be used with up to four wireless Paradigm subwoofers. See dealer for full details on connecting multiple subwoofers.
Zone 2 Operation
Your PT-2 transmitter will work with a subwoofer(s) in a second zone (i.e. another area of your home).
TIP! To minimize the chance of signal dropouts or signal interference, keep the PT-2 transmitter out of range of a microwave oven, mobile telephone or a Bluetooth device operating on the same frequency.

IMPORTANT! Paradigm recommends using speaker-level ORline-level connections. DO NOT USE BOTH CONNECTIONS AT THE SAME TIME.

Your PT-2 transmitter is designed to work with Paradigm brand subwoofers only.
PANEL LAYOUTS


WIRELESS SYNC INSTRUCTIONS

All subwoofers must be unplugged from outlets.
- Plug in PT-2 wire less transmitter.
- Press and hold sync button A on front panel of PT-2 for 3 seconds. The LED B willblink quickly.
- Within 60 seconds of pressing the sync button all subwoofer must be plugged in. Once all subwoofer are synched, the LED will remain in 'on'.
TIP! Once all subwoofers have been synche d, if necessary they can be unplugged and moved without re synching again.
LATENCY SWITCH INSTRUCTIONS
The latency switch .4.1usts the delay between the PT-2's audio signal input and the subwoofer receiver's RF output, optimizing integrity of the wireless transmission. Start with the switch in the 15ms position. If you experience sound quality issues (i.e drop-outs, pops, ticks), you can improve the connection by moving the switch to 20ms or 25ms to increase latency.
LED STATUS
Off: No power.
Fast blinking: Set-up mode.
Dim: Unit in standby mode, no transmission.
Slow blinking, 'off' to bright: Waking from standby mode
and synching.
Slow blinking, dim to bright: At least one subwoofer is synched.
Permanently On: All subwoofers synched and receiving signal.
SPEAKER-LEVEL CONNECTION, VOLUME CONTROLLED BY RECEIVER
Volume Controlocurs at receiver:

flowchart
graph TD
A["Receiver"] --> B["L"]
A --> C["R"]
B --> D["Speaker Level"]
C --> D
D --> E["Low Level Input"]
E --> F["Wireless Subwoofer"]
G["Input"] --> H["Speaker Level"]
I["Output"] --> J["Low Level Input"]
LINE-LEVEL CONNECTION (WITH SUB-OUT/LFE): VOLUME CONTROLLED BY RECEIVER
Receiver with bass management.

flowchart
graph TD
A["Receiver"] --> B["L"]
A --> C["R"]
B --> D["Speaker Level"]
C --> E["Low Level Input"]
D --> F["Wireless Subwoofer"]
E --> F
style A fill:#f9f,stroke:#333
style B fill:#ccf,stroke:#333
style C fill:#ccf,stroke:#333
style D fill:#cfc,stroke:#333
style E fill:#cfc,stroke:#333
style F fill:#fcc,stroke:#333
LINE-LEVEL CONNECTION (NO SUB-OUT/LFE): VOLUME CONTROLLED BY RECEIVER
Receiver without bass management.

flowchart
graph TD
A["Receiver"] --> B["L"]
A --> C["R"]
B --> D["Low Level Input"]
C --> D
D --> E["Speaker Level"]
E --> F["Output"]
F --> G["Input"]
G --> H["Wireless Subwoofer"]
SPEAKER-LEVEL CONNECTION: VOLUME CONTROLLED EXTERNALLY (ZONE 2)
Receiver without line-level connection.

flowchart
graph TD
A["Receiver"] --> B["L"]
A --> C["R"]
B --> D["L"]
B --> E["R"]
C --> F["L"]
C --> G["R"]
D --> H["L"]
D --> I["R"]
E --> J["L"]
E --> K["R"]
F --> L["L"]
F --> M["R"]
G --> N["L"]
G --> O["R"]
H --> P["L"]
H --> Q["R"]
I --> R["L"]
I --> S["R"]
J --> T["L"]
J --> U["R"]
K --> V["L"]
K --> W["R"]
L --> X["L"]
L --> Y["R"]
M --> Z["L"]
M --> AA["R"]
N --> AB["L"]
N --> AC["R"]
O --> AD["L"]
O --> AE["R"]
P --> AF["L"]
P --> AG["R"]
Q --> AH["L"]
Q --> AI["R"]
R --> AJ["L"]
R --> AK["R"]
S --> AL["L"]
S --> AM["R"]
T --> AN["L"]
T --> AO["R"]
U --> AP["L"]
U --> AQ["R"]
V --> AR["L"]
V --> AS["R"]
W --> AT["L"]
W --> AU["R"]
X --> AV["L"]
X --> AW["R"]
Y --> AX["L"]
Y --> AY["R"]
Z --> AZ["L"]
Z --> BA["R"]
AA --> BB["L"]
AA --> BC["R"]
AB --> BD["L"]
AB --> BE["R"]
AC --> BF["L"]
AC --> BG["R"]
AD --> BH["L"]
AD --> BI["R"]
AE --> BJ["L"]
AE --> BK["R"]
AF --> BL["L"]
AF --> BM["R"]
AG --> BN["L"]
AG --> BO["R"]
AH --> BP["L"]
AH --> BQ["R"]
AI --> BQ
AJ --> BN
AJ --> BO
AK --> BN
AL --> BN
AL --> BO
AM --> BN
AM --> BO
AN --> BN
AN --> BO
AO --> BN
AO --> BO
AP --> BN
AP --> BO
AQ --> BN
AQ --> BO
AR --> BN
AR --> BO
AS --> BN
AS --> BO
AT --> BN
AT --> BO
AU --> BN
AU --> BO
AV --> BN
AV --> BO
AW --> BN
AW --> BO
AX --> BN
AX --> BO
AY --> BN
AY --> BO
AZ --> BN
AZ --> BO
BA --> BN
BA --> BO
BB --> BN
BB --> BO
AC --> BN
AC --> BO
AD --> BN
AD --> BO
AE --> BN
AE --> BO
AF --> BN
AF --> BO
AG --> BN
AG --> BO
AH --> BN
AH --> BO
AI --> BN
AI --> BO
AJ --> BN
AJ --> BO
AK --> BN
AK --> BO
AL --> BN
AL --> BO
AM --> BN
AM --> BO
AN --> BN
AN --> BO
AO --> BN
AO --> BO
AP --> BN
AP --> BO
AQ --> BN
AQ --> BO
AR --> BN
AR --> BO
AS & AT --> PB["Paradigm VC-150 Volume Control"]
style PB fill:#f9f,stroke:#333,stroke-width:2px
Zone 2 volume level of full-range speakers and subwoofer may be controlled by the Paradigm VC-150 Volume Control (bld separately). Requires running speaker wire from the Paradigm VC-150 Volume Control back to the Paradigm PT-2 transmitter.
This device contains FCC ID: YZY-HT205 and IC ID: 9261A-HT205. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

RECYCLING AND REUSE GUIDELINES FOR EUROPE In accordance with the European Union WEEE (Waste Electrical and Electron Equipment) directive effective August 13, 2005, we would like to notify you this product may contain regulated materials which, upon disposal, according to the WEEE directive, require special reuse and recycling processing. For this reason Paradigm Electronics Inc. (manufacturers of Paradigm speakers and distributors), we are distributed in European Union members nations to collect and recycle this product at no cost to you. To find your local distributor please contact the dealer from whom you purchased this product or go to our website atwww.paradigm.com Please note that the product only falls under the WEEE directive. When disposing of packaging and other shipping material we encourage you to recycle through the normal channels.