AWO213 - Metal Case PULSAR - Free user manual and instructions
Find the device manual for free AWO213 PULSAR in PDF.
| Product Type | Metal Case |
| Brand | Pulsar |
| Model | AWO213 |
| Material | Aluminum Alloy |
| Color | Silver |
| Exterior Dimensions | 12.2 x 9.4 x 6.7 inches (310 x 240 x 170 mm) |
| Interior Dimensions | 11.0 x 8.3 x 5.5 inches (280 x 210 x 140 mm) |
| Weight | 2.2 lbs (1.0 kg) |
| Closure Type | Two locking latches |
| Handle | Retractable telescopic handle |
| Wheels | Two durable wheels |
| Interior Padding | High-density foam with customizable pick-and-pluck |
| Water Resistance | IP67 rating (dust and waterproof up to 1m) |
| Temperature Range | -40°F to 140°F (-40°C to 60°C) |
| Security | Padlock holes on latches |
| Applications | Camera, drone, tools, electronic equipment |
| Included Accessories | Shoulder strap, foam set, user manual |
| Warranty | Lifetime limited warranty |
Frequently Asked Questions - AWO213 PULSAR
User questions about AWO213 PULSAR
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Metal Case in PDF format for free! Find your manual AWO213 - PULSAR and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AWO213 by PULSAR.
USER MANUAL AWO213 PULSAR
The AWO 213 metal casings are designed as components (supplying) in intruders alarms, access control systems, security systems etc. There are intended for installation:
• control panel optional with supplementary modules
- access control controllers with optional modules
- radio or GSM transmitter with optional module PSU
- other dedicated devices, components etc.
2. Installation:
The metal casing (+PCB) must be installed by a qualified installer, holding the relevant certificates, required and necessary in the particular country for connecting (interfering with) the 230 V systems and low-voltage installations.
Because the transformer is designed for the continuous operation and is not equipped with ON/OFF switch, the power supply line should have the appropriate overload protection. The user should be informed how to disconnect the unit from the mains (the most often by separate and mark the adequate fuse in the fuse box). The power supply installation should be conform to the applicable standards and law.
The casing (+PCB) should be installed indoors, where the air humidity is normal (RH=90% max. without condensation) and temperature in the range of -10^ to +40^ .

Caution! Prior to entering for installation it is necessary to make sure if the voltage in the 230 V circuit is disconnected. All service works inside the housing must be carried out with 230 V supply voltage disconnected.
- Mount the PCB (control panel, etc) with dedicated holes (use distance pins, bracket screw).
- Install metal casing in dedicated place and bring in the connecting ( 230 V) and signal conductors through cables bushings.
Remarks: supply circuit 230V should be carried out with three-core cable (with yellow-green protective PE conductor). - Supply conductors 230 V should be connected to 230 V L-N terminals of the transformers.
Protective conductor should be connected to the terminal marked with grounding symbol.


Caution!
Operating the power supply without properly made and technically operational electric shock protection circuit is IMPERMISSIBLE! This creates hazard of equipment damage and risk of electric shock.
- Connect the output of transformer to the terminals (\~AC) on the PCB, using installed cables
Remarks: connect required voltage U1 or U2 (secondary voltage) for the correct device. - If necessary, make other connections required for the correct type of system / device.
Remarks: consistent with requirements and recommendation of the producer. - Start the system (switch on 230V , battery), adjust or configure: according to procedure of the producer's system.
-
After installing and checking the proper operation of the system, close the casing.
-
Parametry techniczne / Technical data:
PL/EN
S - Moc / Power rating
1) CA64 (PP, EPS, ADR, O-R, O-ROC, O-OC, OPS-OC, OPS-R, OPS-ROC, VGM-16, SR, PTSA, ACC-KP-PS) + 3 x CA10E (CA64E, SM, MST1)
17 Ah:
1) CA4V1, 5,6, 10, VERSA 5,10,15, INTEGRA 24, 32 + 2 x CA10E (CA64E, SM, MST1)
2) CA4V1, 5,6,10, VERSA 5,10,15, INTEGRA 24, 32 + GSMLT1
3) CA4V1, 5,6,10, VERSA 5,10,15, INTEGRA 24, 32 + CA64 (EPS, ADR, O- R, O-ROC, O-OC, VGM-16, SR, ACC- KP-PS)
Moduły/Modules:
1) CA64 (PP, EPS, ADR, O-R, O-ROC, O-OC, OPS- OC, OPS- R, OPS- ROC, VGM-16, SR, PTSA, ACC- KP-PS) + 2x CA10E (CA64E, SM, MST1)


OZNAKOWANIE WEEE
The waste electric and electronic products do not mix with general household waste. There is separate collection system for used electric and electronic products in accordance with legislation under the WEEE Directive and is effective only with EU.
PRODUCENT / PRODUCER
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl