Irritrol 2500SF - Watering

2500SF - Watering Irritrol - Free user manual and instructions

Find the device manual for free 2500SF Irritrol in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Irritrol 2500SF - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Pop-up Sprinkler
Model 2500SF
Brand Irritrol
Pop-up Height 4 inches (10.2 cm)
Body Diameter 2.5 inches (6.4 cm)
Inlet Size 1/2 inch female NPT
Operating Pressure Range 30 - 80 psi (2.1 - 5.5 bar)
Flow Rate Range 2.0 - 12.0 GPM (7.6 - 45.4 L/min)
Radius Adjustment Partial to full circle (adjustable)
Nozzle Options Interchangeable, 8-15 ft radius
Material Impact-resistant plastic body
Weight 0.3 lbs (0.14 kg) approx.
Power Source Water pressure only (no electrical)
Installation Threaded riser or direct bury
Warranty 2 years limited manufacturer warranty
Maintenance Clean filter screen and nozzle regularly
Cleaning Rinse with water; avoid harsh chemicals
Spare Parts Replacement nozzles, risers, and seals available
Safety Use only with clean water; do not exceed max pressure

Frequently Asked Questions - 2500SF Irritrol

What is the maximum radius of the Irritrol 2500SF sprinkler?
The maximum radius is up to 15 feet depending on the nozzle installed and water pressure.
Can the Irritrol 2500SF be used for both full and partial circle watering?
Yes, the sprinkler has an adjustable arc from 45 to 360 degrees, allowing partial or full circle coverage.
What is the recommended operating pressure for the 2500SF?
The recommended operating pressure is between 30 and 80 psi (2.1 to 5.5 bar).
How do I adjust the spray pattern on my Irritrol 2500SF?
Turn the turret at the top of the sprinkler to adjust the arc. For radius adjustment, replace the nozzle or adjust the pressure screw if available.
Does the 2500SF require electricity to operate?
No, it is hydraulically operated by water pressure alone; no electrical connection needed.
How do I winterize the Irritrol 2500SF sprinkler?
Before freezing temperatures, remove the sprinkler from the riser, drain all water, and store indoors or blow out the system with compressed air.
What maintenance does the 2500SF require?
Periodically clean the filter screen and nozzle to prevent clogging. Inspect seals and replace if leaking.
Can I replace the nozzle on my Irritrol 2500SF?
Yes, the nozzle is interchangeable. Unscrew the old nozzle and replace with a compatible Irritrol nozzle for different radius and flow.
What is the inlet thread size on the 2500SF?
The inlet is a 1/2 inch female NPT thread, compatible with standard risers and fittings.
Is the Irritrol 2500SF suitable for underground installation?
Yes, it is designed for buried installation with a pop-up height of 4 inches, commonly used in lawn and garden irrigation.

User questions about 2500SF Irritrol

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Watering in PDF format for free! Find your manual 2500SF - Irritrol and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 2500SF by Irritrol.

USER MANUAL 2500SF Irritrol

Installation Instruction

Introduction

The Irritrol® 2500 Series is a classic example of value in design. Borrowing heavily from the proven 205 Series valves, the 2500 host a full menu of enhancements including a patented "floating metering system" for consistent performance in dirty water applications and a rugged, double-beaded diaphragm for long-term performance with no leakage. The 2500's manual internal bleed enables the valve to be opened without filling the valve box with water. And servicing is made easy and efficient with captured screws. These are just some of the features that make the 2500 Series valve rugged for a reason.

Features

  • Patented "floating metering system"
  • High-flow, low friction loss design combined with low-flow capability
  • Rugged, double-beaded EPDM diaphragm
  • Internal and external bleed (flush mode)
    • Full stainless steel metering system
  • Heavy-duty, corrosion and UV-resistant PVC and stainless steel construction
  • Available in female NPT or slip configurations (no male pipe adapter required)
  • Floating bleed tube allows thermal expansion without affecting performance.

Irritrol 2500SF - Features - 1

natural_image 3D technical illustration of a mechanical valve assembly (no text or symbols visible)

Specifications

Models:

2500 Series electric - 1"

2507 Series electric - 34 "

Body Style:

Globe with slip connection or

NPT threaded connection

Dimensions:

2500: 5 1/8" H x 2 ^3 / _4 " W x 5" L

2507: 5 1/8" H x 2 ^3 / _4 " W x 5" L

Flow range: .25 - 30 GPM

Operating Pressure: 10-150 PSI

Electrical

Solenoid (standard): 24 VAC

Inrush volt-amp: 24 VAC - 9.6 VA

Inrush: 0.4 amps

Holding volt-amp: 24 VAC - 4.8 VA

Holding: 0.2 amps

Friction Loss Chart (US PSI)

GPM Flow by Size

ModelSize.252510152030
25001"5.403823.0022.20190310510
2507 34 "2.75840385400240898619

Recommendations Guideline

  • In commercial installations, it is advantageous to install the valves in a valve box. This enables the valve to be easily located, accessed, and maintained.
  • Partially fill the bottom of the valve box with clean aggregate to facilitate drainage.
  • Locate the valve box away from structures, hardscape features (such as sidewalks), and large planting locations.
  • Locate the valve box in shrub beds and at right angles to structure locations.
  • If valves are installed below grade without a valve box, access to the top of the valve should be provided by using a section of 4" PVC pipe and a valve cover installed directly over each valve.

Irritrol 2500SF - Recommendations Guideline - 1

Using pipe dope on valve connections can cause thread damage and failure of the valve body.

Use only PTFE tape or pipe thread sealant.

  • The valve can be installed at any angle without affecting operation.
  • Use direct-burial wire, utilizing different color codes for each station control wire and one color for the common wire to all valves.
  • Waterproof wire splice connectors are absolutely essential for proper electric control system operation. Follow the installation instructions provided with the connectors for optimum waterproof splice protection.
  • Leaving a wire expansion loop at each valve location on long-run wire lengths is recommended.

Installation and Operating Instructions

Automatic in-line valve can be operated either manually or electrically.

In areas where freezing conditions occur, be sure to install a way to drain the system before freezing weather arrives. To do that, use a shut-off valve on the main line feeding the sprinkler system. Shut off the water supply then electrically operate each valve for at least a few minutes (dry run). This vents the upper cavity of the valve and makes sure the valve is completely drained.

Although the valve is rated to 150 psi, a pressure regulator should be used where local water pressure exceeds 80 psi. (See Uniform Plumbing Code, Sec. 1007(b).) We suggest using a pressure regulator with any automatic valve to ensure long life, uniform performance, and controlled operation.

Step 1 - Flush line thoroughly before installing valve. This valve is designed with slip x slip inlet connections and glues directly to 1" PVC pipe.

Step 2 - Use PVC pipe cement only. Glue valve directly to 1" PVC pipe. No threading is necessary.

Caution: Do not plug in the transformer until all valves has been connected.

Step 3 - For each location, run one common wire that will serve all the valves at that location. Wiring can be buried

underground under the pipes. For runs under 800 feet, use 18 gauge direct burial irrigation wire. For runs over 800 feet, use 14 gauge direct burial irrigation wire.

Each valve has two wires. One will be connected as the "common" wire. Splice the common wire from each valve together to make a single wire. Connect it to the timer. Be sure all splices are joined with wire nuts. Again, make sure all wire splices are waterproof.

The remaining wire on each valve is the "lead" wire. Connect each lead wire to the timer at the numbered terminals, one lead wire per terminal.

Step 4 - Plug in your timer. Be sure you use only a timer with a Class 2, 24V transformer.

Step 5 - Turn water supply on.

Note: The valve will remain on until the air in the upper cavity is bled off. To do that, turn the manual bleed screw counterclockwise until water squirts out. Then either tighten the bleed screw or electrically run the valve for about thirty seconds. The valve will shut off within a minute.

Notice: This is not a backflow prevention valve. In needs to be installed in conjunction with an approved backflow prevention device. Check state and local plumbing codes prior to installation.