Dormakaba

Auditcon 52 - Lock Dormakaba - Free user manual and instructions

Find the device manual for free Auditcon 52 Dormakaba in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Dormakaba Auditcon 52 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electronic Lock
Brand Dormakaba (formerly Kaba Mas)
Model Auditcon 52
Power Source PowerStar™ Technology – internal generator powered by manual dial turns
Battery Assist (Optional) 9 Volt Alkaline battery for LED flashing during time delay/open window
Lock Modes Single Mode (one combination required) and Dual Custody Mode (two combinations required)
Maximum Users 2 users (User 1 and User 2)
Default Combination 502550 (for both users in factory reset)
Combination Length 6 digits
Bolt Types Supported Dead Bolt (manual locking) and Slide Bolt (auto locking)
Time Delay (Model T52 only) 1-99 minutes delay, 1-20 minutes opening window
Wrong Try Penalty 5 wrong tries = 3-minute lockout; each additional wrong try adds 3 minutes
UL Listing Note For UL listed installations, only one user can be activated
Patents Covered by multiple U.S. patents (e.g., 4,803,860, 5,170,431, etc.)
Mounting Inside door, compatible with various containers
Indicators Green and red LED flashes with beeps for status
Operating Temperature Not specified in manual
Dimensions Not specified in manual
Weight Not specified in manual
Material Not specified in manual

Frequently Asked Questions - Auditcon 52 Dormakaba

How do I change the combination on the Auditcon 52?
Open the container door. Press # and then 1 for User 1 (Manager) or ## and then 1 for User 2. Enter the current combination (default 502550). Enter a new six-digit combination, then enter it again for verification. Test the new combination before closing the door.
What is the default combination for the Auditcon 52?
The default combination is 502550 for both users after factory reset or mode change.
How do I set the time delay on a Model T52?
Press # then 5. Enter the current combination (User 1 for Single Mode, or both users for Dual Custody). Enter the desired delay (01-99 minutes) and confirm. Then enter the opening window duration (01-20 minutes) and confirm. The change takes effect after the next opening.
What should I do if I get locked out after too many wrong attempts?
The lock will enter a 3-minute lockout after 5 wrong tries. Each additional wrong try adds 3 minutes. During lockout, red flashes and beeps occur when powering the lock. Wait for the lockout to expire before trying again.
How do I add a second user (User 2) in Single Mode?
Only the Manager User (User 1) can add User 2. Press # then 3. Enter the User 1 combination. User 2 is added with default combination 502550 and access status Enabled.
How do I change the lock mode from Single to Dual Custody?
Press # then 2. Enter the current Manager User (User 1) combination. The lock mode changes and all combinations reset to 502550. Note: For Dual Custody, both User 1 and User 2 combinations are required to open.
Why is my lock not powering on?
The Auditcon 52 uses PowerStar™ Technology and must be manually powered by briskly turning the dial back and forth before each operation. If it still doesn't respond, check for any obstructions or contact support.
How do I replace the battery on a battery assist lock?
Enter a valid combination to unlock and open the container door. Locate the battery clip inside the door near the lock and replace the old battery with a fresh 9 Volt Alkaline battery.
What is the difference between Dead Bolt and Slide Bolt operation?
For a Dead Bolt, you must manually turn the dial to the Home position, then clockwise to retract the bolt. For a Slide Bolt, after entering the combination, the bolt automatically slides when the container handle is turned. The lock response also differs: Dead Bolt gives one slow green flash, Slide Bolt gives continuous green flashes.
Can I use the Auditcon 52 in a UL listed installation?
Yes, but for UL listed installations, only one user can be activated (Single Mode with only User 1). Dual Custody Mode and User 2 are not permitted.

User questions about Auditcon 52 Dormakaba

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Lock in PDF format for free! Find your manual Auditcon 52 - Dormakaba and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Auditcon 52 by Dormakaba.

USER MANUAL Auditcon 52 Dormakaba

natural_image Black KARA remote control device with keypad and buttons (no visible text or symbols on body)

LOCK MODES

A maximum of two users can exist in a lock. A lock can operate in either Single Mode or Dual Custody Mode.

Note: For a UL listed installation, only one user can be activated.

- Single Mode

Single Mode defaults to having only a Manager User (User 1) in the lock. A second user (User 2) can then be added by the Manager User (User 1). (See section on Manager User Operations.)

In Single Mode only one valid user combination is required to open the lock - the Manager User (User 1) combination or the User 2 combination.

Note: Default lock status from the factory is Single Mode with an opening combination of "502550" for the Manager User (User 1).

- Dual Custody Mode

Dual Custody Mode defaults to two users in the lock - User 1 and User 2.

Two user combinations are required to open the lock - the User 1 combination and the User 2 combination.

Note: Manager User Operations are not available in Dual Custody Mode.

LOCK OPERATING CONVENTIONS

- The power source for the Auditcon 2 Lock Series is PowerStar™ Technology. With this technology an internal generator is used to create all necessary power.

Important Note: The lock must be manually powered before each operation by briskly turning the dial back and forth ⏻ ⏻.

  • To clear a combination or keystroke, press the key.
  • If the bolt is not retracted within 4-6 seconds after a valid opening combination is accepted, the lock will “relock”.

Please note the following operational differences based on the type of bolt you have installed:

  • Dead Bolt (Manual Locking) Technology: There is a “Home” position for the dial on the lock that is directly related to the manual retraction or extension of the bolt. In the “HOME” position, the lip of the dial will cover the red “open lock” indicator. The dial must be positioned here on a lock “Open” operation before you can successfully open the lock. The dial must be turned to the right (CW) to retract the bolt and unlock the lock. The dial must be turned to the left (CCW) to extend the bolt and lock the lock. The lock may not open if more than a 5 lb. force is applied to the end or side of the bolt.
  • Slide Bolt (Auto Locking) Technology: Once a combination has been entered and accepted, the lock bolt movement works in conjunction with the bolt works of the container. When the bolt works are disengaged to open the container, the lock bolt will slide into the “unlocked” or retracted position. Once the bolt works are extended to the locked position, the lock bolt automatically slides into the “locked” position. The lock will not open if force is applied to the end or side of the bolt.

LOCK RESPONSES

  • The lock is “powered” when simultaneous green Ⓖ and red ⚡ flashes display with a beep 🔍.
    • Each keystroke generates a green flash G with a beep 🏠.
  • The completion of a step within an operation is indicated by a green flash-G-with a beep.
  • The successful completion of an operation is indicated by simultaneous green G and red R flashes.
  • If a valid combination or combinations are entered to open the lock, the lock will respond as follows to indicate that the lock is ready to open:

Dead Bolt - 1 slow green flash

Slide Bolt - Continuous green flashes Ⓖ... for approx. 5 seconds

- An error is indicated by three red flashes with beeps.

- If the Battery Assist option is included on your lock and a 9 Volt Alkaline has been installed for Battery Assist, the LEDs will continually flash throughout the duration of a Time Delay or Open Window period. There is not a battery low indicator for Battery Assist. If the feature is not functioning properly, check the battery.

TO UNLOCK

  1. For a Dead Bolt, place the dial in the Home position.

  2. • For Single Mode † (Factory combination is "502550".)

Enter Manager User (User 1) or User 2 combination.

- For Dual Custody Mode † †

Enter User 1 or User 2 combination.

Enter the second combination.

Wrong Try Penalty: 5 wrong tries = 3 min. lockout

Each additional wrong try = 3 min. lockout

Red flashes with beeps 📄 will occur during the lockout while lock is powered.

  1. For a Dead Bolt, dial right (clockwise) until the lock bolt is retracted. For a Slide Bolt, rotate the container handle to unlock.

CHANGE COMBINATION

Caution: When selecting a combination, do not use a birthday or other predictable data that could give a correlation between the user and the combination. Before changing a combination, open the container door to allow testing with the new combination.

  1. • For User 1 (Manager User in Single Mode)

Press # and then 1.

- For User 2 (Must be added by Manager User in Single Mode)

Press #, # and then 1.

  1. Enter current combination. (Factory combination is "502550".)

  2. Enter new six-digit combination.

  3. Enter new combination again for verification.

  4. Open the lock with the new combination before closing container.

  5. Record new combination and store it in a secure place.

  6. Enter new combination again for verification.

  7. Open the lock with the new combination before closing container.
  8. Record new combination and store it in a secure place.

CHANGE LOCK MODE (SINGLE / DUAL CUSTODY)

Note: Changing the lock mode will reset the combination(s) to "502550".

  1. Press # and then 2.
  2. • If changing from Single to Dual Custody Mode

Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - CHANGE LOCK MODE (SINGLE / DUAL CUSTODY) - 1

- If changing from Dual Custody to Single Mode

Enter User 1 or User 2 combination.

Dormakaba Auditcon 52 - CHANGE LOCK MODE (SINGLE / DUAL CUSTODY) - 2

Enter the second combination.

Dormakaba Auditcon 52 - CHANGE LOCK MODE (SINGLE / DUAL CUSTODY) - 3

SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only)

  1. Press # and then 5.

  2. • For Single Mode ⋆ (Factory combination is "502550".)

Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 1

- For Dual Custody Mode ††

Enter User 1 or User 2 combination.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 2

Enter the second combination.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 3

  1. Enter number of minutes (01-99) you want to delay lock opening or "00" to disable

time delay.

  1. Enter the desired time delay again for verification.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 4

If not "00", proceed to step 6.

  1. Enter number of minutes (01-20) for the delayed opening window.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 5

  1. Enter number of minutes for the delayed opening window again for verification.

Dormakaba Auditcon 52 - SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only) - 6

Note: A change in delayed opening will not take effect until after the next opening of the lock.

TO UNLOCK WITH TIME DELAY SET (Model T52 only)

If operating a Model T52 Lock with Time Delay set to something other than 0, red flashes

R will display after a combination has been entered and will continue during the delay while the lock is powered.

Note: If you have a Time Delay Display unit installed, the display unit will count down to the end of the time delay period and will count up to the end of the window period.

When the delay time expires, you must power ⬇ ⬇ the lock.

Green flashes 📊 display with beeps 🔍 to indicate the opening window is active and will continue during the window while the lock is powered.

For a Dead Bolt, place the dial in the Home position.

Enter the combination(s) to open the lock.

BATTERY MAINTENANCE

To replace a battery on a battery assist lock, enter a valid combination to unlock the lock and then open the container door. Locate the battery clip mounted inside the door near the lock and replace the battery with a fresh 9 Volt Alkaline battery.

These operations are only available in Single Mode and can only be performed by the Manager User (User 1). All Manager User Operations involve management of User 2.

User 2 can have a lock access status of “Enabled” or “Disabled”. If “Enabled”, User 2 can open the lock. When User 2 is added to the lock, the default lock access status is “Enabled”. The Manager User (User 1) has the authority to change the lock access status for User 2 and can temporarily “Disable” lock access for the user.

ADD USER 2

  1. Press # and then 3.

Dormakaba Auditcon 52 - ADD USER 2 - 1

  1. Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - ADD USER 2 - 2

Note: User 2 is added to the lock as "Enabled" with a factory combination of "502550". User 2 can change the User 2 combination while Enabled, but only the Manager User (User 1) can change the lock access status.

DELETE USER 2

  1. Press # and then 4.

Dormakaba Auditcon 52 - DELETE USER 2 - 1

  1. Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - DELETE USER 2 - 2

DISABLE USER 2

  1. Press # and then 7.

Dormakaba Auditcon 52 - DISABLE USER 2 - 1

  1. Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - DISABLE USER 2 - 2

Note: If you try to disable User 2 when already disabled, you will get an error indication.

ENABLE USER 2

  1. Press # and then 6.

Dormakaba Auditcon 52 - ENABLE USER 2 - 1

  1. Enter Manager User (User 1) combination.

Dormakaba Auditcon 52 - ENABLE USER 2 - 2

Note: If you try to enable User 2 when already enabled, you will get an error indication.

Notice: Information in this document is subject to change without notice. Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.

© 2005 Kaba Mas Corporation. All rights reserved.

PowerStar Technology and Auditcon are registered trademarks of Kaba Mas Corporation in the United States and/or other countries.

This product is covered by one or more of the following U.S. patents:

4,803,860 5,170,431 5,265,452 5,271,253 5,410,301 5,451,934 5,488,358 5,488,660

5,493,279 5,511,401 5,590,917 5,592,838 5,709,114 5,774,058 5,774,059 5,870,914

5,873,276 5,881,589 5,893,283 5,896,026 D366,822 D388,308 D388,309