Product Type Electromagnetic Lock
Brand Dormakaba
Model RCI 8365
Voltage Options 12 VDC or 24 VDC, selectable via jumpers
Voltage Selection 12VDC: jumpers on pins 1-2 and 3-4; 24VDC: jumper on pins 2-3 (factory default)
Power Requirement Must use filtered and regulated DC power supply
Mounting Internal mounting tabs, fits into frame mortise; armature plate mounts on door with U-clamp and sex nuts
Armature Type Pivoting armature plate with rubber washer for breakaway
Breakaway Feature Rubber washer on armature bolt expands when power removed to break vacuum; do not remove or trim washer
Compliance Must be installed per all applicable building and life safety codes
Safety Warning Improper installation may cause lock, armature, and hardware to disengage and fall, causing serious injury
Installation Requires experienced installer; door frame must be structurally sound; use thread locking compound on all screws
Maintenance Quarterly inspection of mounting fasteners; clean contacting surfaces with non-abrasive cleaner
Thread Locking Compound Provided with product; apply to armature bolt and lock mounting screws
Power Supply Compatibility Dormakaba offers compatible power supplies and switching devices for 8300 series
Exterior Use Not approved for exterior installation
Doorstop Use Do not use as doorstop; voids warranty
Inspection Frequency Quarterly: check all fasteners and armature plate movement
Cleaning Clean electromagnetic lock and armature plate contacting surfaces periodically with non-abrasive cleaner
Current Draw Refer to product manual for specific values (not provided in excerpt)
Application Sliding doors (frame and door cutout dimensions provided)
Warranty Do not install on exterior or use as doorstop; improper use voids warranty

Frequently Asked Questions - RCI 8365 Dormakaba

What voltage does the RCI 8365 operate on?
The lock can operate on 12 VDC or 24 VDC. Voltage is selected via internal jumpers: for 12V, place jumpers on pins 1-2 and 3-4; for 24V, use a single jumper on pins 2-3 (factory default).
How do I install the RCI 8365 electromagnetic lock?
Installation requires an experienced installer. First, cut mortises in the frame and door using provided centerline references. Mount the locking tabs inside the frame, wire the lock (red wire positive, white negative), and secure it on the tabs. Mount the armature plate on the door using the U-clamp and sex nuts. Apply thread locking compound to all screws. Finally, validate by energizing and gently closing the door.
How do I set the voltage jumper?
Remove the endcap to access the jumper pins. For 12VDC, install two jumpers: one on pins 1-2 and one on pins 3-4. For 24VDC, install only one jumper on pins 2-3. Ensure correct polarity: red wire positive (+), white wire negative (-).
What maintenance is required for the RCI 8365?
Perform quarterly inspections: check all mounting fasteners for tightness, and clean the contacting surfaces of the lock and armature plate with a non-abrasive cleaner. Also inspect the armature plate: it should pivot slightly on the bolt but feel secure.
Can the RCI 8365 be used outdoors?
No. The manual states: Do not install this product on the exterior of buildings. It is designed for indoor use only.
Why won't the magnet hold the door?
Ensure the armature plate makes full contact with the lock face. You may need to add extra steel washers behind the armature plate to bring it closer. Also verify the voltage jumper setting and that the power supply is providing correct voltage. If the rubber washer on the armature bolt is missing or trimmed, the lock may appear to hold even when power is off – replace it.
What is the holding force of the RCI 8365?
The holding force is not specified in the provided manual excerpt. For typical Dormakaba 8300 series locks, holding force is often around 600 lbs (2670 N), but confirm with the full product datasheet.
Is the RCI 8365 suitable for sliding doors?
Yes. The manual includes cutout dimensions for a sliding door frame and provides specific dimensions for the frame mortise and door armature mortise. See the table for 'Sliding Door Frame' measurements.
What tools are required for installation?
You will need: a drill with appropriate bits, countersink tool, screwdrivers, thread locking compound (provided), and a voltmeter to verify voltage. Also have steel washers on hand for armature adjustment.
Can I replace the armature plate rubber washer?
The rubber washer is crucial for breaking the vacuum when power is removed. Do not remove or trim it. If lost, contact Dormakaba for a replacement part. Without it, the lock may retain residual holding force even when de-energized.

User questions about RCI 8365 Dormakaba

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Serrure électromagnétique in PDF format for free! Find your manual RCI 8365 - Dormakaba and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RCI 8365 by Dormakaba.

USER MANUAL RCI 8365 Dormakaba

Pre-Installation Instructions

  1. This product must be installed according to all applicable building and life safety codes.
  2. Due to the variety of mounting configurations available with this product, a survey and assessment of the physical area in which the product will be installed must be performed.
  3. The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock. The structural integrity of the mounting surfaces must be strong enough to meet or exceed the holding force of the product.
  4. The product must be protected from potential damage due to intruders or tampering.
  5. The product should be installed in a location that will not hinder or create a potential safety hazard to authorized personnel accessing the protected area.
  6. Because electromagnetic locks are used in a variety of applications and different door frame configurations, an experienced installer with knowledge of this product must make a determination of the optimal mounting method for this specific application.

PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE END-USER UPON COMPLETION OF THE INSTALLATION.

  1. Do not install this product on the exterior of buildings.
  2. Do not use as a doorstop. This will void warranty.
  3. Installation of this product should be done by an experienced installer with knowledge of this product.

NOTE: It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended time.

WARNING: Improper installation, maintenance, inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock, armature plate and associated hardware to disengage and fall, causing serious bodily injury and property damage. dormakaba Canada Inc. and/or dormakaba USA Inc. will not be liable to the installer, purchaser, end user or anyone else for damage or injury to person or property due to improper installation, care, storage, handling, maintenance, inspection, abuse, misuse or act of God or nature involving this product or any related accessories or parts.

Instructions

1. Mortise Cutouts

Hold lock against frame at desired level. Mark the lock's horizontal centerline on the frame and transfer that mark to the door.

Determine the vertical centerline of the door thickness and mark this on both the door and the frame.

Using these centerline references, cut out the frame lock mortise and the door armature mortise, as illustrated.

2. Lock Mounting Tabs

Temporarily fasten the two mounting tabs under the lock flanges. Insert the lock assembly into the frame cavity until the tabs are resting on top. Mark the location of the tab mounting holes.

Drill and countersink these four holes to accept the 3/16" screws provided.

Remove tabs from lock. Mount the tabs inside the frame.

3. Wire and Mount Lock

Remove endcap.

Set voltage jumpers as follows:

12VDC operation = two jumpers are used.

Contact pins 1 to 2 and 3 to 4.

24VDC operation = only one jumper is used.

Contact pins 2 to 3. (factory setting)

Connect the positive (+) power lead to the red and the negative

(-) lead to the white wire.

Connecting wire should be of sufficient gauge for the lock being installed and the distance being run.

See page 3 table for current draw specifications.

Secure lock on tabs in

mortise cavity, carefully applying thread locking compound to the hardware provided, as in Fig. 1

Dormakaba RCI 8365 - Wire and Mount Lock - 1

Close-up of hands operating a circuit board with wires and components (no visible text or symbols)

4. Mount Armature

Using centerline references on the door and illustration provided, drill the four “U” clamp mounting holes.

Position the “U” clamp inside door as shown on Fig. 2. Insert the two pan head sex nuts from the outside of the door and through the “U” clamp. Insert the two button head hex bolts from the inside of the door and secure into the sex nuts.

Position bolt with rubber head through armature plate. Add 3 washers (steel - rubber - steel) onto threads. Carefully apply thread-locking compound to exposed thread and mount onto the "U" clamp.

NOTE: Do not over tighten. The armature plate must be allowed to pivot on the mounting bolt to allow proper alignment with the magnet surface. If the plate is not aligned with the magnet surface, the lock may lose holding force or not lock at all.

The head of the armature mounting bolt ships with a rubber washer affixed to it. This washer should project slightly beyond the surface of the armature plate. This is to allow the washer to expand when power is removed and break the air vacuum between the plate and the magnet surface. If this washer is removed or trimmed, the lock will appear to have some holding force even when power is removed.

5. Validate

With a release device already installed, energize circuit and close door gently. If magnet does not secure, verify that armature plate is making contact with face of magnetic block. If necessary, install additional steel washers behind armature plate to move armature plate closer to block face and retest.

Inspection and Maintenance

This product and all related accessories or parts must be inspected and maintained on a quarterly basis. Contacting surfaces of the electromagnetic lock and armature plate must be kept free of contaminating materials. Surfaces must be cleaned periodically with a non-abrasive cleaner.

All mounting fasteners must be inspected on a quarterly basis. When properly installed, the ends of the armature plate allow a slight movement but the plate will feel secure when grasped at the bolt. There should be no movement to the mounting bracket or housing of the electromagnetic lock.

For added safety, thread locking compound has been provided for the armature plate bolt and the four electromagnetic lock mounting screws.

WARNING: Improper installation, maintenance, inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock, armature plate and associated hardware to disengage and fall, causing serious bodily injury and property damage.

PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE END-USER UPON COMPLETION OF THE INSTALLATION.

NOTE: All RCI brand electromagnetic locks must be powered with filtered and regulated DC power supplies. dormakaba offers a full line of power supplies and switching devices that are suitable for use with the 8300 Series locks.

Sliding Door Frame 8365 Electromagnetic Lock Frame Frame Extrusion Mounting Tab A B Sliding Door Frame Exterior Side Cut out C E F J* H H G C Interior Side cut C out C C C Interior side door drilling Figure.1 Figure.2 Do not over tighten preventing movement. Voltage Current 12VDC 0.40A 24VDC 0.20A

FRAMEDOOR
A B E F G HI (Interior)* J (Exterior)*
Inches Fractions1-3/88 1-5/16 5-3/16 1-1/169/16 11/321/2
Inches Decimal1.38 8.001.31 5.19 1.050.55 0.340.50
(mm) metric35.0 203.0 33.0132.0 27.0 14.0 8513.0

* Interior and exterior drill sizes are different
NOTE: Specifications are subject to change without notice.