MGate MB3170I-T - Industrial gangway Moxa - Free user manual and instructions
Find the device manual for free MGate MB3170I-T Moxa in PDF.
| Product Type | Industrial Modbus Gateway |
| Brand | Moxa |
| Model | MGate MB3170I-T |
| Dimensions (without ears) | 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in) |
| Dimensions (with ears) | 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.9 in) |
| Power Input | 12 to 48 VDC |
| Power Consumption (max) | 555 mA @ 12-48 VDC |
| Operating Temperature | -40 to 75°C (-40 to 167°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Humidity | 5 to 95% RH (non-condensing) |
| Serial Ports | 1 RS-232/422/485 DB9 male + 2 terminal block (RS-422/485) |
| Ethernet Port | 1 RJ45 10/100 Mbps; optional fiber (100BaseFX) |
| Protocol Conversion | Modbus TCP to Modbus ASCII/RTU |
| Max TCP Connections | 32 (masters/slaves) |
| Max Serial Slaves | 31 (Modbus RTU/ASCII) |
| Mounting | DIN-rail or wall mounting |
| LED Indicators | PWR1, PWR2, RDY, Ethernet (speed/link), P1/P2 (serial), FX (fiber) |
| Reset Button | Hold 5 seconds to load factory defaults |
| Relay Output | 1 digital relay alarm (NC), 1 A @ 30 VDC |
| Magnetic Isolation (serial) | 2 kV (for "I" models) |
| Hazardous Location Certifications | UL/cUL Class 1 Div 2, ATEX Zone 2, IECEx |
| Default IP Address | 192.168.127.254 |
| Default Username | admin |
| Default Password | moxa |
Frequently Asked Questions - MGate MB3170I-T Moxa
User questions about MGate MB3170I-T Moxa
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Industrial gangway in PDF format for free! Find your manual MGate MB3170I-T - Moxa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MGate MB3170I-T by Moxa.
USER MANUAL MGate MB3170I-T Moxa
MGate MB3170/MB3270 Series Quick Installation Guide
Version 8.2, January 2021
Technical Support Contact Information www.moxa.com/support
MOXA®
© 2021 Moxa Inc. All rights reserved.
P/N: 1802031700017

Overview
The MGate MB3170 and MB3270 are 1 and 2-port advanced Modbus gateways that convert between Modbus TCP and Modbus ASCII/RTU protocols. They can be used to allow Ethernet masters to control serial slaves, or to allow serial masters to control Ethernet slaves. Up to 32 TCP masters and slaves can be connected simultaneously. The MGate MB3170 and MB3270 can connect up to 31 or 62 Modbus RTU/ASCII slaves, respectively.
Package Checklist
Before installing the MGate MB3170 or MB3270, verify that the package contains the following items:
• MGate MB3170 or MB3270 Modbus gateway
• Quick installation guide (printed)
- Warranty card
Optional Accessories:
• DK-35A: DIN-rail mounting kit (35 mm)
• Mini DB9F-to-TB Adaptor: DB9 female to terminal block adapter
- DR-4524: 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
- DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
- DR-120-24: 120W/5A DIN-rail 24 VDC power supply with 88 to 132 VAC/176 to 264 VAC input by switch
NOTE Please notify your sales representative if any of the above items is missing or damaged.
Hardware Introduction
LED Indicators
| Name | Color | Function |
| PWR1 | Red | Power is being supplied to the power input |
| PWR2 | Red | Power is being supplied to the power input |
| RDY | Red | Steady: Power is on and the unit is booting up |
| Blinking: IP conflict, DHCP or BOOTP server did not respond properly, or a relay output occurred | ||
| Green | Steady: Power is on and the unit is functioning normally | |
| Blinking: Unit is responding to locate function | ||
| Off | Power is off or power error condition exists | |
| Ethernet | Amber | 10 Mbps Ethernet connection |
| Green | 100 Mbps Ethernet connection | |
| Off | Ethernet cable is disconnected or has a short | |
| P1, P2 | Amber | Serial port is receiving data |
| Green | Serial port is transmitting data | |
| Off | Serial port is not transmitting or receiving data | |
| FX | Amber | Steady on: Ethernet fiber connection, but port is idle. |
| Blinking: Fiber port is transmitting or receiving data. | ||
| Off | Fiber port is not transmitting or receiving data. |
Reset Button
Press the Reset button continuously for 5 sec to load factory defaults:
The reset button is used to load factory defaults. Use a pointed object such as a straightened paper clip to hold the reset button down for five seconds. Release the reset button when the Ready LED stops blinking.
Panel Layouts
The MGate MB3170 has a male DB9 port and a terminal block for connecting to serial devices. The MGate MB3270 has two DB9 connectors for connecting to serial devices.

Hardware Installation Procedure
STEP 1: After removing the MGate MB3170/3270 from the box, connect the MGate MB3170/3270 to a network. Use a standard straight-through Ethernet (fiber) cable to connect the unit to a hub or switch. When setting up or testing the MGate MB3170/3270, you might find it convenient to connect directly to your computer's Ethernet port. In this case, use a crossover Ethernet cable.
STEP 2: Connect the serial port(s) of the MGate MB3170/3270 to a serial device.
STEP 3: The MGate MB3170/3270 is designed to be attached to a DIN rail or mounted on a wall. The two sliders on the MGate MB3170/3270 rear panel serve a dual purpose. For wall mounting, both sliders should be extended. For DIN-rail mounting, start with one slider pushed in, and the other slider extended. After attaching the MGate MB3170/3270 on the DIN rail, push the extended slider in to lock the device server to the rail. The two placement options are illustrated in the accompanying figures.
STEP 4: Connect the 12 to 48 VDC power source to terminal block power input.
Wall or Cabinet Mounting
Mounting the MGate MB3170/3270 Series on to a wall requires two screws. The heads of the screws should be 5 to 7 mm in diameter, the shafts should be 3 to 4 mm in diameter, and the length of the screws should be more than 10.5 mm.

NOTE Wall mounting is certified for use in maritime applications.
Wallmount

natural_image
Vertical line drawing of a device with ports and connectors (no text or symbols)DIN Rail

natural_image
Pure technical line drawing of a rectangular frame with mounting brackets (no text or symbols)
natural_image
Pure technical line drawing of a rectangular electronic component or enclosure (no text or symbols)
Push here to lock to the DIN-Rail
Software Installation Information
ou can download the MGate Manager, User's Manual, and Device Search Utility (DSU) from Moxa's website: www.moxa.com. Please refer to the User's Manual for additional details on using the MGate Manager and DSU.
The MGate MB3170/3270 also supports login via a web browser.
Default IP address: 192.168.127.254
Default account: admin
Default password: moxa
Pin Assignments
Ethernet Port (RJ45)

| Pin | Signal |
| 1 | Tx+ |
| 2 | Tx- |
| 3 | Rx+ |
| 6 | Rx- |
Serial Port (DB9 Male)

| Pin | RS-232 | RS-422/RS-485 (4W) | RS-485 (2W) |
| 1 | DCD | TxD- | - |
| 2 | RxD | TxD+ | - |
| 3 | TxD | RxD+ | Data+ |
| 4 | DTR | RxD- | Data- |
| 5 | GND | GND | GND |
| 6 | DSR | - | - |
| 7 | RTS | - | - |
| 8 | CTS | - | - |
| 9 | - | - | - |
NOTE For the MB3170 Series, the DB9 male port can only be used for RS-232.
Terminal Block Female Connector on the MGate (RS-422, RS-485)

| Pin | RS-422/RS-485 (4W) | RS-485 (2W) |
| 1 | TxD+ | - |
| 2 | TxD- | - |
| 3 | RxD+ | Data+ |
| 4 | RxD- | Data- |
| 5 | GND | GND |
Power Input and Relay Output Pinouts

| V2+ V2- | V1+ V1- | |||||
| Shielded Ground | DC Power Input 1 | DC Power Input 1 | Relay Output | Relay Output | DC Power Input 2 | DC Power Input 2 |
Optical Fiber Interface
| 100BaseFX | ||||
| Multi-mode | Single-mode | |||
| Fiber Cable Type OM1 | 50/125 μm | G.652 | ||
| 800 MHz*km | ||||
| Typical Distance | 4 km | 5 km | 40 km | |
| Wave-length | Typical (nm) | 1300 | 1310 | |
| TX Range (nm) | 1260 to 1360 | 1280 to 1340 | ||
| RX Range (nm) | 1100 to 1600 | 1100 to 1600 | ||
| Optical Power | TX Range (dBm) | -10 to -20 | 0 to -5 | |
| RX Range (dBm) | -3 to -32 | -3 to -34 | ||
| Link Budget (dB) | 12 | 29 | ||
| Dispersion Penalty (dB) | 3 | 1 | ||
| Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.Note: Compute the "typical distance" of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB). | ||||
Specifications
| Power Requirements | |
| Power Input | 12 to 48 VDC |
| Power Consumption (Input Rating) | MGate MB3170, MGate MB3170-T, MGate MB3270, MGate MB3270-T:12 to 48 VDC, 435 mA (max.)MGate MB3270I, MGate MB3270I-T, MGate MB3170-M-ST, MGate MB3170-M-ST-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T:12 to 48 VDC, 510 mA (max.)MGate MB3170I, MGate MB3170I-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T:12 to 48 VDC, 555 mA (max.) |
| Operating Temperature | 0 to 60°C (32 to 140°F),-40 to 75°C (-40 to 167°F) for -T model |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Humidity | 5 to 95% RH |
| Magnetic Isolation Protection (serial) | 2 kV (for "I" models) |
| DimensionsWithout ears:With ears extended: | 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.9 in) |
| Relay Output | 1 digital relay output to alarm (normal close):current carrying capacity 1 A @ 30 VDC |
| Hazardous Location | UL/cUL Class 1 Division 2 Group A/B/C/D, ATEX Zone 2, IECEx |
This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
ATEX and IECEx Information


MB3170/3270 Series
- Certificate number: DEMKO 18 ATEX 2168X
- IECEx number: IECEx UL 18.0149X
- Certification string: Ex nA IIC T4 Gc
Ambient Range : 0°C ≤ Tamb ≤ 60°C (For suffix without -T)
Ambient Range : -40^ ≤ Tamb ≤ 75^ (For suffix with -T)
- Standards covered:
ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4
-
The conditions of safe usage:
-
The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
- The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP4 in accordance with IEC/EN 60079-0.
- Conductors suitable for Rated Cable Temperature ≥ 100^
- Input conductor with 28-12 AWG (max. 3.3 mm ^4 ) to be used with the devices
MB3170I/3270I Series
- ATEX Certificate number: DEMKO 19 ATEX 2232X
- IECEx number: IECEx UL 19.0058X
- Certification string: Ex nA IIC T4 Gc
Ambient Range : 0^ C ≤ Tamb ≤ 60^ C (For suffix without -T)
Ambient Range : -40^ ≤ Tamb ≤ 75^ (For suffix with -T)
- Standards covered:
ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4
-
The conditions of safe usage:
-
The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
- The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with IEC/EN 60079-0.
- Conductors suitable for Rated Cable Temperature ≥ 100^
- Input conductor with 28-12 AWG (max. 3.3 mm ^4 ) to be used with the devices
Address of manufacturer: No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004, Taiwan