Savio Glacier TG-03 - Air conditioner

Glacier TG-03 - Air conditioner Savio - Free user manual and instructions

Find the device manual for free Glacier TG-03 Savio in PDF.

📄 14 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Savio Glacier TG-03 - page 4
View the manual : English EN Polski PL
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Thermal Grease (CPU/GPU)
Brand Savio
Model Glacier TG-03
Thermal Conductivity 13.5 W/m·K
Working Temperature Range -50°C to 250°C
Thermal Impedance < 0.102 °C·in²/W
Density 2.9 ± 0.08 g/ml
Electrical Conductivity 0 pS/m (non-conductive)
Package Contents Thermal grease, spatula, user manual
Application Method Thin layer or 3×3 mm dot on IHS
Recommended Cleaning Isopropyl alcohol or dry cloth
Storage Cool dry place; may separate over time
Safety Keep away from children, avoid ingestion/eye contact
Manufacturer Elmak Sp. z o.o., Poland
Warranty Support Email: support@savio.net.pl

Frequently Asked Questions - Glacier TG-03 Savio

What is the thermal conductivity of Savio Glacier TG-03?
The thermal conductivity is 13.5 W/m·K, suitable for high-performance cooling.
What is the operating temperature range?
It operates from -50°C to 250°C, making it ideal for both extreme cooling and high-temperature applications.
How should I apply the thermal grease?
Clean the surfaces with isopropyl alcohol, then apply a thin layer using the included spatula or a 3×3 mm dot in the center of the IHS.
Is the thermal grease electrically conductive?
No, it has 0 pS/m electrical conductivity, so it is safe to use without risk of short circuits.
What is included in the package?
The package contains the thermal grease, a spatula for application, and a user manual.
Can I use this grease on both CPU and GPU?
Yes, it is suitable for CPU and GPU IHS and cooler bases.
How should I store the thermal grease?
Store in a cool, dry place. The grease may discharge trace amounts of silicone oil during storage, which is normal; remix before use.
What should I do if grease gets in my eyes?
Rinse eyes thoroughly with plenty of water and seek medical attention if irritation persists.
How do I clean excess or spilled grease?
Use a dry cloth or isopropyl alcohol to clean excess grease from surfaces.
Is this product safe for children?
No, keep out of reach of children. Do not ingest. If ingested, rinse mouth with water and contact medical support.

User questions about Glacier TG-03 Savio

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual Glacier TG-03 - Savio and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Glacier TG-03 by Savio.

USER MANUAL Glacier TG-03 Savio

Thank you for choosing Savio product!

Savio Glacier TG-03 - 1

If our product meets your expectations, share your opinion with other people on the portal ceneo.pl, on social media or on the website of the store where you made the purchase. If you want to show off our device on SAVIO FanPage on Facebook, we will be very pleased.

Savio Glacier TG-03 - 2

If there is something that we could improve on our products, please write to us at support@savio.net.pl

Thanks to your feedback, we will be able to better adapt the product to your expectations.

Before starting the use of purchased device it is recommended to read the whole manual.

1. Technical specification\*:

TG-01 TG-02 TG-03 TG-04
Thermal conductivity:4.7 W/m·K8.5 W/m·K13.5 W/m·K14.5 W/m·K
Working temperature:-50 - 250°C-50 - 250°C-50 - 250°C-50 - 280°C
Thermal impedance:<0.155 °C · in 2 /W<0.135 °C · in 2 /W<0.102 °C · in 2 /W<0.095 °C · in 2 /W
Density:2.5 ± 0.08 g/ml2.6 ± 0.08 g/ml2.9 ± 0.08 g/ml2.8 ± 0.08 g/ml
Electrical conductivity:0 pS/m 0pS/m 0 pS/m0 pS/m

*Depending on the model purchased.

2. Package content:

• SAVIO GLACIER thermal grease
- User manual
- Spatula for spreading the grease

3. Applying thermal grease:

3.1 Clean the processor IHS surface and the radiator base with a dry cloth or Isopropyl Alcohol.
3.2 Spread a thin layer of thermal grease over the processor IHS with a spatula added to the set. Alternatively, you can apply a 3 × 3 mm drop of the grease in the middle

of the IHS.

3.3 Assemble the cooling system of the processor. The best method is to screw in the opposite corners of the frame. It allows even spreading of the grease.

3.4 After mounting the cooling system, check if there are no leakages. If leakages appear, it means that there is too much grease applied. You have to clean the excess with a dry cloth or Isopropyl Alcohol.

4. Additional information:

While storing, the grease can discharge trace amounts of silicone oil. That is normal and does not have any detrimental effect on grease efficiency. The paste should be re-mixed during the application.

5. Safety conditions:

- Keep out of reach of children.

- It is forbidden to consume the product.

- In case of contact with the eye, you need to wash your eyes with a substantial amount of water.

- In case of inhaling fumes from the grease, it is necessary to go outside to breathe fresh air for a while.

  • In case of ingestion it is not necessary to induce vomiting. Rinse your mouth with plenty of water.
  • If you notice any side effects, not mentioned above, please contact medical support.

Information for customers and contractors and communication regarding complaints:

Pursuant to Article 13 section 1 and 2 of the General Data Protection Regulation (EU) 2016/679 of the European Parliament and of the Council of 27 April 2016 (hereinafter referred to as GDPR), please be advised that Elmak Sp. z o.o., with its registered seat at ul. Morgowa 81; 35-323 Rzeszów becomes the Administrator of your personal data. The Specialist for General Data Protection (SODO) can be contacted in writing to: SODO, Elmak Sp. z o.o., ul. Morgowa 81; 35-323 Rzeszów, via e-mail address: sodo@elmak.pl, and by phone at +48 (17) 854 98 14. Your personal data will be processed in order to perform the contract, in accordance with Article 6(1)(b) of the aforementioned regulation, to the extent resulting from tax laws and financial regulations. Recipients of your personal data include entities authorized by legal regulations to

obtain personal data as well as processing entities providing services to Elmak Sp. z o.o. Your personal data will be stored on the basis of Administrator's legitimate interest. You have the right to access your data, and the right to rectify, delete or limit processing of your data. You have the right to lodge a complaint to the supervisory body if you believe that the processing violates the GDPR. The provision of personal data is voluntary, however, a failure to provide such data may result in a refusal to conclude or in termination of a contract. Your personal data will not be subjected to automated decision making, including profiling referred to in Article 22 section 1 and 4 of the GDPR of April 27, 2016.

LET'S PLAY 2GETHER!

POLSKI

Instrukcja obsługi

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Savio

Model : Glacier TG-03

Category : Air conditioner