Type of Product Measurement device (multimeter)
Dimensions 150 x 70 x 30 mm
Weight 200 g
Power Supply 9V battery (6F22)
Display Analog or digital (3 1/2 digit LCD)
Main Functions DC voltage, AC voltage, DC current, resistance, continuity test
Measurement Ranges 200 mV to 600 V (DC), 200 mV to 600 V (AC), 200 µA to 10 A (DC)
Accuracy ±0.5% (DCV), ±1.2% (ACV)
Input Impedance 10 MΩ (DCV)
Overload Protection Internal fuse (200 mA/250 V) and PTC resistor
Operating Temperature 0°C to 40°C
Storage Temperature -10°C to 50°C
Humidity ≤80% RH (non-condensing)
Safety Standards CAT II 600 V, CE compliant
Maintenance and Cleaning Wipe with dry cloth; do not use solvents. Replace battery and fuse as needed.
Spare Parts and Repairability Fuses and test leads available; service by qualified personnel.
General Information Brand: PCE Instruments; Model: AM 30; Category: Measurement

Frequently Asked Questions - AM 30 PCE Instruments

How do I measure DC voltage with the AM 30?
Set the rotary switch to the appropriate DC voltage range (V-). Connect the black test lead to COM and red to VΩmA. Probe the circuit and read the display.
What type of battery does the AM 30 use?
The device uses a standard 9V battery (type 6F22). Replace when the battery indicator shows low.
How do I perform a continuity test?
Turn the rotary switch to the continuity function (diode symbol with a sound wave). Connect the test leads to the circuit. The buzzer sounds if resistance is below 30 Ω.
What is the maximum voltage I can measure?
The AM 30 can measure up to 600 V DC or AC. Do not exceed this limit to avoid damage.
How do I replace the fuse?
Disconnect all leads and turn off the meter. Open the battery compartment, remove the old fuse (typically 200 mA/250 V), and install a new one of the same rating.
Can I measure current with the AM 30?
Yes, for DC current up to 10 A. Set the switch to the A range, move the red lead to the 10A jack, and connect in series with the load.
What does the 'OL' reading mean?
'OL' stands for overload indication. It means the measured value exceeds the selected range. Switch to a higher range.
How do I store the device properly?
Keep in a dry, dust-free place within temperature range -10°C to 50°C. Remove the battery if storing for long periods.
Is the AM 30 safe for household electrical measurements?
Yes, it is rated CAT II 600 V, suitable for measurements on household appliances and wall outlets. Follow basic safety precautions.
Where can I find the user manual?
The manual is available for free download on notice-facile.com in the product page. You can also request a translated version via email.

User questions about AM 30 PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual AM 30 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AM 30 by PCE Instruments.

USER MANUAL AM 30 PCE Instruments

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : AM 30

Category : Measurement