Product Type Water Dispenser
Brand Breville
Model the AquaStation Chilled LWA300
Product Dimensions (HxWxD) 400 x 300 x 300 mm (approx.)
Weight 5.2 kg (approx.)
Water Tank Capacity 3 liters
Power Consumption 800 W (cooling)
Voltage 220-240 V ~ 50/60 Hz
Water Temperature Options Chilled and ambient
Cooling System Compressor-based
Installation Type Countertop / freestanding
Water Filter Included carbon filter for purification
Control Type Push-button dispensing
Drip Tray Removable and easy to clean
Safety Features Child safety lock, overheat protection
Cleaning Easy-clean surfaces, removable drip tray
Warranty 2 years (standard)

Frequently Asked Questions - the AquaStation Chilled LWA300 BREVILLE

How do I clean the AquaStation Chilled LWA300?
Regular cleaning is essential. Wipe the exterior with a damp cloth. Remove and clean the drip tray with mild soap. Use a descaling solution for the internal tank every 3 months. Refer to the manual for detailed cleaning instructions.
Can I use tap water directly in the dispenser?
Yes, but it is recommended to use filtered or bottled water to prolong the life of the internal filter and ensure better taste. The dispenser includes a carbon filter to reduce impurities from tap water.
How often should I change the water filter?
The filter should be replaced every 6 months or after dispensing 300 liters, whichever comes first. Regular replacement ensures optimal water quality and prevents bacterial growth.
Why is the water not cold enough?
Check that the power cord is plugged in and the unit is switched on. Allow up to 1 hour for initial cooling. Ensure the ventilation grills are not blocked. If problem persists, the cooling system may require servicing.
Does the dispenser have a child lock?
Yes, the Breville AquaStation Chilled is equipped with a child safety lock to prevent accidental dispensing. Activate it by pressing the lock button for 3 seconds.
How do I install the water dispenser?
Place the unit on a flat, stable surface. Plug into a grounded outlet. Fill the tank with water. Wait for the compressor to cool the water (approx. 1 hour). Then it is ready to use. Do not tilt or lay it down during transport.
What is the water tank capacity?
The tank capacity is 3 liters. This allows for multiple servings before needing a refill. The tank is transparent so you can easily monitor water level.
Can this dispenser provide hot water?
No, the model 'Chilled' is designed for chilled and ambient water only. It does not have a heating function. For hot water, consider Breville's hot water dispenser models.
How do I descale the water dispenser?
Mix a descaling solution with water according to manufacturer instructions. Pour into the tank, run the dispenser until the solution drains, then flush with clean water 3 times. Descaling every 3 months prevents mineral buildup.
Is the Breville AquaStation energy efficient?
The unit uses compressor cooling which is energy efficient for its size. It has an automatic energy-saving mode that turns off the compressor when not in use for extended periods. Typical power consumption is about 0.8 kWh per day.

User questions about the AquaStation Chilled LWA300 BREVILLE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water dispenser in PDF format for free! Find your manual the AquaStation Chilled LWA300 - BREVILLE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. the AquaStation Chilled LWA300 by BREVILLE.

USER MANUAL the AquaStation Chilled LWA300 BREVILLE

the AquaStation™ Chilled

Instruction Book - Suits all LWA300 Models

BREVILLE the AquaStation Chilled LWA300 - the AquaStation™ Chilled - 1

natural_image Exterior view of a modern stainless steel Breville air fryer with control knob (no visible text or symbols beyond branding)

Breville®

BREVILLE the AquaStation Chilled LWA300 - the AquaStation™ Chilled - 2

Contents

2 Breville Recommends Safety First
8 Components
10 Features
12 Assembly
15 Operation
17 Care, Cleaning & Storage
19 Troubleshooting

BREVILLE RECOMMENDS SAFETY FIRST

At Breville we are very safety conscious. We design and manufacture consumer products with the safety of you, our valued customer, foremost in mind. In addition, we ask that you exercise a degree of care when using any electrical appliance and adhere to the following precautions. Misuse can cause potential injuries.

BREVILLE the AquaStation Chilled LWA300 - BREVILLE RECOMMENDS SAFETY FIRST - 1

IMPORTANT

Do not store the water dispenser on any other side other than upright and level on its support feet. This is important for the compressor.

MAIN TECHNICAL SPECIFICATIONS

Product Model LWA300BSS
Filter Model LWA063WHT
Filter Life 90 days or approximately200L, whichever comes first
Rated Voltage 220-240V
Rated Frequency 50Hz
Rated Power Consumption 100 W
Applicable Water Source Municipal tap water: 5~40°C
Product Dimensions (LxWxH)Approx. 391 x 273 x 455
Weight (kg) Approx. 9.54

Tested against: NSF/ANSI Standard 42 for the reduction of chlorine (taste and odour), & NSF/ANSI 372, lead content.

Tested to remove/reduce microplastics, floating particles/sediment, pesticides, chlorine, limescale & heavy metals.

Testing was performed under standard laboratory conditions. The contaminants or other substances removed or reduced by this filter are not necessarily in all users' water. Filter performance may vary based on local water conditions.

IMPORTANT SAFEGUARDS

READ ALL INSTRUCTIONS BEFORE USE AND SAVE FOR FUTURE REFERENCE

  • Carefully read all instructions before operating and save for future reference.
  • Remove and safely discard any packaging material and promotional labels before using the AquaStation™ Chilled for the first time.

• Always ensure the appliance is properly assembled before use. Follow the instructions provided in this book.
- The AquaStation™ Chilled must be used only with the Breville filter supplied or replacement product code LWA063.
- This appliance has been designed specifically for the purpose of filtering and chilling drinking quality water only. Under no circumstances should this appliance be used to chill any other liquids.
- Do not place the appliance near the edge of a bench or table during operation. Ensure that the surface is level, clean and free of water and other substances.
- Do not operate the appliance on a sink drain board.
- Do not operate the appliance in an enclosed space, or within a cupboard.
- Never immerse the appliance, power cord or power plug in water, or allow moisture to come into contact with these parts.
- Do not move the appliance while it is switched on.
• Always ensure the appliance returns to standby mode, then

turn the power off at the power outlet and remove the power plug from the power outlet before attempting to move the appliance, when the appliance is not in use and before cleaning and storing.

  • Do not remove the water tank from the power base during operation.
  • If the water tank is removed from the power base during water dispensing, the appliance will automatically stop.
  • Always fill the water tank with water between the minimum (MIN) and maximum (MAX) as marked on the water tank.
  • Too little water will result in the appliance not operating and Water Droplet will turn solid red. Filling above the maximum mark (MAX) may result in water splashing from the water tank.
  • Ensure the water level is always above the MIN level for optimum dispensing flow rate.
    • The lid should always be correctly fitted on the water tank except when refilling.
  • Do not place the appliance in direct sunlight. Colour fading and discolouration may occur when the appliance is consistently exposed to sunlight

  • Allow the appliance to cool down before moving or cleaning any parts.

  • This appliance is intended to filter tap water only. Do not put water of unknown quality into the appliance. Use only cold or room temperature water. Do not use for the preparation of baby formula.
  • Do not fill the water tank with hot water. Water added to the water tank should not be less than 5^ or more than 40^ . If water in the tank is outside these temperatures, discard and fill with cold tap water.
  • Do not leave the appliance unattended during operation.
  • Do not remove filter whilst the appliance is operating.

BREVILLE the AquaStation Chilled LWA300 - READ ALL INSTRUCTIONS BEFORE USE AND SAVE FOR FUTURE REFERENCE - 1

WARNING

  • Do not operate the appliance on an inclined plane. Do not move appliance unless the appliance is turned off and unplugged from the power outlet.
  • Keep the appliance and all parts clean. Follow the cleaning instructions provided in this book.
  • Any procedure not listed in this instruction book should be performed at an authorised Breville Service Centre.

IMPORTANT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES

  • Fully unwind the power cord before use.
  • Connect only to a 230V or 240V power outlet.
  • The appliance must be used on a properly grounded outlet. If you are not sure, please consult a qualified electrician.
  • Do not, under any circumstances, modify the power plug or use a power plug adapter.
  • Do not place this appliance on or near a heat source, such as a hot plate, oven or heaters.
  • Position the appliance at a minimum distance of 20cm away from walls, curtains and other heat or steam sensitive materials and provide adequate space above and on all sides for air circulation.
  • Do not let the power cord hang over the edge of a bench or table, touch hot surfaces or become knotted. Keep away from hot gas or electric burners, or where it could touch a heated oven.
  • This appliance is for household use only. Do not use this appliance for anything other than its intended use. Do not

use in moving vehicles or boats. Do not use outdoors. Misuse may cause injury

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
    • Children should be supervised to ensure that they do not play with the appliance.
    • Always turn the appliance to the OFF position, switch off at the power outlet and unplug at the power outlet when the appliance is not in use.
  • Before cleaning, always turn the appliance to the OFF position, switch off at the power outlet, unplug at the power outlet and remove the power cord, if detachable, from the appliance and allow all parts to cool.
    • To protect against electric shock, do not immerse the power cord, power plug or appliance in water or any other liquid or allow moisture to come in contact with the parts, unless it is recommended in the cleaning instructions.

  • Any maintenance other than cleaning should be performed at an authorised Breville Service Centre

  • It is recommended to regularly inspect the appliance. To avoid a hazard, do not use the appliance if power cord, power plug or appliance becomes damaged in any way. Return the entire appliance to the nearest authorized Breville Service Centre for examination and/or repair.
  • The installation of a residual current device (safety switch) is recommended to provide additional safety protection when using electrical appliances. It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance. See a qualified electrician for professional advice.
  • During electrical storms, the appliance should be disconnected from the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry.

- Cleaning and user maintenance shall not be made by children without supervision.

SPECIFIC INSTRUCTIONS FOR WATER FILTER

  • Filter cartridge should be kept out of reach of children.
  • Store any unused filter cartridges in a dry place sealed in the original packaging.
  • Protect filter cartridges from heat and direct sunlight. Only remove from packaging before using.
  • Do not use a filter cartridge that is damaged.
  • Do not open filter cartridge housing to access the material inside.
  • If you are absent for a prolonged period of time, empty and clean the water tank and replace the filter cartridge before next use.
  • Refer to the filter installation instructions found in the 'Assembly' section of these instructions.

BREVILLE ASSIST™ PLUG

- Your Breville appliance comes with a unique Assist™ Plug, conveniently designed with a finger hole in the power plug for easy and safe removal from the power outlet. For safety reasons, it is recommended you plug your Breville appliance directly into its own electrical outlet on a dedicated circuit separate from other appliances. If the electric circuit is overloaded with other appliances, your appliance may not function properly. Use in conjunction with a power strip or extension cord is not recommended.

FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS

BREVILLE the AquaStation Chilled LWA300 - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - 1

Components

A. Water tank lid with easy-grip handle

B. The Activ360™ 4-Stage Filter with pull ring for easy removal

C. Filter holder

D. Water tanks Including a removable, external 6L water tank plus an internal 2L chilling chamber (not shown) NOTE - Total external tank capacity is 6L, however, it is recommended to always fill the external water tank with water between the minimum (MIN- 2L) and maximum (MAX- 5L) as marked on the water tank. Filling above the maximum mark (MAX-5L) may result in water splashing from the water tank.

E. Function Dial & Start/Stop Button

F. Control Panel Indicator lights START/ STOP, 5°C, 10°C, 15°C, Ambient, Filter Reset, Cooling, Ready

G. Dispensing spout

H. Dispensing area 20cm cup clearance height with tray in place, 23cm height if drip tray removed

I. Detachable magnetic drip tray

J. Removable tray grill for cleaning

K. Non-marking, non-slip feet

Not Shown

• Breville Assist™ Plug
- Drain Plug & Cap (Located underneath unit)

BREVILLE the AquaStation Chilled LWA300 - Not Shown - 1

text_image BrandAir A B C D E F G H I J K

BREVILLE the AquaStation Chilled LWA300 - Not Shown - 2

Control Panel

START/STOP

Water droplet light flashes 3 times then illuminates white when ready or when dispensing water. The light extinguishes when in standby mode.

5^ C, 10^ C \& 15^ C

Light illuminates against the selected cold temperature.

CHILLING

Illuminates blue when compressor is on.

Flashes on and off to indicate that the compressor is turning on and off to maintain the set temperature (ambient, 5°C, 10°C & 15°C).

READY

Light illuminates white when set temperature has been reached

AMBIENT

Light illuminates white when selected.

FILTER RESET

Light illuminates as a reminder to change the filter cartridge once the filter life timer has counted down.

BREVILLE the AquaStation Chilled LWA300 - FILTER RESET - 1

text_image Breville 15°C 10°C AMBIENT 9°C FILTER RESET START I STOP READY

FILL TANK

The water droplet light on the START/STOP button will illuminate solid red to alert the user that the water tank needs to be filled. The unit will not dispense water until the tank is refilled. Once the tank has been filled, The water droplet light on the START/STOP button will no longer illuminate.

BREVILLE the AquaStation Chilled LWA300 - FILL TANK - 1

NOTE

Take care when removing the water tank from the base after use as residual water may drip.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

  • The unit will not dispense any water while the tank is below the minimum water level.
  • Ensure the water level is always above the MIN level for optimum flow rate.

PROGRAM TABLE

Function Water Dispensing Flow Rate^Preset Temp °C ^Temp Range °C Temp +/- IncrementsPreset Volume MLS
Cold1L/min55 to 155Stops dispensing after 1 minute.
Ambient 1L/min Temp of Waterinside Water Tank#N/A N/A Stops dispensingafter 1 minute.

^Temperature is measured in the chilling chamber not from the spout. #Dispensed Ambient water temperature will vary.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTES

  • Cold water temperature settings are measured in the chilling chamber not the dispensed temperature at the spout or in the cup.
  • When dispensing ambient water, if START/STOP is not pressed to stop water flow, dispensing will automatically stop after 60 seconds.
  • Ambient water temperature will vary. The temperature dispensed will be influenced by the external factors surrounding the unit itself. An increase in the air temperature will cause water tank temperature to increase as well.
  • If the water temperature in the tank becomes too warm, discard and replace with cold tap water. Water temperature in the tank should not be dispensed if above 40°C.

BREVILLE the AquaStation Chilled LWA300 - NOTES - 1

Features

The Breville AquaStation ^™ Chilled when used with the Activ360 ^™ 4-stage fast flow water filtration system, provides cleaner, great-tasting ambient or cold filtered water.

The Activ360TM Filter, with 4 distinct levels of filtration, removes contaminants from water that can cause bad taste and odour, which may potentially be harmful to your health.

1. Stage 1- Pre-Sediment Filter

Filters microplastics and floating particles

2. Stage 2-Ion-Exchange Resin Filter

Filters limescale and metals

3. Stage 3- Activated Carbon Filter

Filters Pesticides and Chlorine

4. Stage 4- Post Filter

Filters fine particles

* 4-stage fast flow filtration tested and/or certified to remove/reduce microplastics, floating particles/sediment, pesticides, chlorine, limescale & heavy metals.

For more information, visit Breville.com

No Plumber Required

The benchtop unit will start to work as soon as assembled, water is added and the power cord is connected to a power source; then simply press to dispense filtered water. No need to plumb into mains water.

Filter Life Counter

The AquaStation™ unit reminds you to replace the filter every 90 days or approximately 200L of water*, whichever comes first, to ensure the best filtration performance.

You may choose to change your filter more frequently in areas with poor water quality.

*The filter change alert is set at 90 days or approximately 200L of water, whichever comes first, with performance based on typical municipal drinking water quality, however, water quality may vary considerably from one area to the next which may affect the life of the water filter and more frequent replacement may be required.

Filter Reset Replacement Alert

START/STOP button continuously flashes in red as a reminder to change the filter cartridge once the filter timer has counted down.

Removable, Magnetic Drip Tray

The drip tray can easily be removed to accommodate different sizes of cups, glasses or reusable bottles. The magnetic edge helps to keep the tray in place when attached at the base. Empty regularly to avoid overspill.

Water Level Sensor

The water tank is equipped with a floating sensor to detect water levels and will automatically stop dispensing when the water level becomes too low. The water droplet light on the START/STOP button will illuminate solid red.

One-way Tank Valve

The water tank has been designed with a one-way valve so that it can be removed from the unit even if water is still in the tank. This prevents the water from leaking when removed from the dispensing unit. Be mindful however that there may be some residual water droplets when removed.

BPA Free\*

All parts that come into direct contact with water are made from BPA Free* materials

* Breville makes its BPA Free claim for this product based on independent laboratory testing performed for all the food contact plastic materials of the product per EU Commission regulation No 10/2011. BPA Free Material is used in all parts that come into contact with food.

WATER QUALITY

As far as contained in tap water, the contaminants or other substances reduced by the Activ360 ^™ water filter are not necessarily in all users' water. Tap water may contain impurities and heavy metals such as lead, copper, chlorine, limescale, pesticides and other contaminants like microplastics which all lead to impaired taste.

BREVILLE the AquaStation Chilled LWA300 - WATER QUALITY - 1

CAUTION

Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. This product should only be used with water that has been adequately chlorinated or disinfected. For use with municipal cold water only.

BREVILLE the AquaStation Chilled LWA300 - CAUTION - 1

Assembly

BEFORE FIRST USE

- Remove and safely discard any packaging material or promotional labels attached to your benchtop unit and filter. Check for any missing or damaged parts as per the components list.

BREVILLE the AquaStation Chilled LWA300 - BEFORE FIRST USE - 1

NOTE

As an important part of our quality control process, your unit has been individually tested. As a result, you may notice a small amount of condensation or water droplets on the inside of the water tank. There is no need for concern. Please remove and discard the protective red silicone rubber cap from the spout before use.

  • Remove the Activ360™ 4-Stage filter from the water tank and set aside.
  • Do not wash the filter or insert into the water tank until 'Flushing the Breville AquaStation' and 'Preparing the Activ360 Filter' instructions are completed as found in this book.
  • Place the unit on a dry, flat level surface.
  • Wash the water tank lid, water tank in warm soapy water with a soft, non-abrasive cloth. Rinse and dry thoroughly with a clean, soft, lint-free cloth before returning to the unit.
  • Assemble the water tank back onto the power base.
  • Plug the power plug into a 230/240V power outlet and turn on the power outlet.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

IMPORTANT

When moving the unit, always lift from the base using two hands and set down gently on a flat and level surface.

FLUSHING THE BREVILLE AQUASTATION

It is important to flush and rinse the dispensing system before using the unit for the first time. Before first use, it is recommended to carry out the below steps without the Activ360™ Water Filter in place.

  1. Fit only the water tank into place on the base of the unit with the lid removed.
  2. Fill the tank with cold tap water to the MAX level. Never fill past the MAX level.
  3. Place a 1L container under the dispensing spout
  4. Press the START/STOP button once to start dispensing ambient water until the container is full, then press the START/STOP button once again to stop dispensing. Discard the collected water.
  5. Repeat steps 3-5 until all the water in the tank has been dispensed. The unit will stop dispensing when the water level is too low or automatically after 60 seconds.
  6. Proceed to the next step, 'Preparing the Activ360™ Filter'.

PREPARING THE ACTIV360™ FILTER

Flushing the filter is required every time you insert a new filter cartridge.

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 1

text_image 90d + (<<)

The START/STOP button light will flash continuously in red to notify after 90 days or 200L of water filtered as an alert that it is time to replace the filter cartridge.

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 2

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 3

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 4

  1. Lift the water tank from the unit, remove the lid and set aside. Lifting by the ring, remove the filter cartridge from the filter holder and discard any remaining water inside the water tank.

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 5

  1. Remove the new filter cartridge from its packaging.

BREVILLE the AquaStation Chilled LWA300 - PREPARING THE ACTIV360™ FILTER - 6

NOTE

It is normal for the filter to appear moist when removed from its wrapping. This is condensation from the hygienic steam sterilisation process.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

BREVILLE the AquaStation Chilled LWA300 - NOTE - 2

  1. Immerse the filter in a bowl of tap water and gently shake until there are no air bubbles. Soak filter in the tap water for 10 minutes.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 3

  1. Once soaked, insert the filter into the filter holder and push down firmly to secure in place.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 4

NOTE

Make sure the filter is tightly fitted.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

BREVILLE the AquaStation Chilled LWA300 - NOTE - 2

BREVILLE the AquaStation Chilled LWA300 - NOTE - 3

BREVILLE the AquaStation Chilled LWA300 - NOTE - 4

BREVILLE the AquaStation Chilled LWA300 - NOTE - 5

  1. To flush and activate the new filter cartridge, add 2L of water to the water tank and return to the unit. Place a 2L empty container under the spout. Turn the FUNCTION dial until the indicator reaches AMBIENT, then press the FUNCTION dial once to select. Press START/STOP again to start dispensing water into the container.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 6

  1. Fill the container to full, then discard the collected water.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 7

BREVILLE the AquaStation Chilled LWA300 - NOTE - 8

  1. Once flushed, fill the water tank with tap water up to the MAX line and return the tank to the unit.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 9

BREVILLE the AquaStation Chilled LWA300 - NOTE - 10

  1. Turn the FUNCTION dial until the indicator reaches FILTER RESET, then press the FUNCTION dial once to reset the filter counter. The START/STOP button light will stop flashing and FILTER RESET light will turn off.

  2. The unit is now ready to use

BREVILLE the AquaStation Chilled LWA300 - NOTE - 11

NOTE

When preparing the Activ360 ^™ filter for the first time use of your AquaStation ^™ , there is no need to action step 8 for filter reset; once the filter is installed, the unit will automatically begin the filter life counter.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

IMPORTANT

  • A dirty filter may reduce the performance of the unit.
    • The filter is not washable.
  • Use only the original Breville filter specifically intended for use with the AquaStation water machines.
  • Filter replacement alert is set to 90 days or approximately 200L of water, whichever comes first, however, for higher-than-normal consumption or poor water quality, more frequent changing may be required. If you need to change your filter before the filter replacement alert activates at 90 days or approximately 200L.

BREVILLE the AquaStation Chilled LWA300 - IMPORTANT - 1

NOTE

To exit FILTER RESET without resetting the filter, turn the dial to other temperature setting.

  • Press and hold the START/STOP button for 3 seconds, The START/STOP button light will flash continuously in red and "FILTER RESET" light illuminate, press the START/STOP button once to reset the filter time once you have changed the filter cartridge.
  • Water quality varies considerably from one area to the next and has an effect on the life of the water filter cartridge. For optimum performance, the filter change alert will activate after 90 days.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

  • No filter or an incorrectly fitted filter may cause the unit to operate less effectively and/or may cause damage to the unit.
  • The filter must be fitted in the filter holder with the pull ring facing upwards.
  • From time to time, small floating black particles may escape from the filter into the water. This is a natural carbon fibre which is food grade safe and not harmful to health.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

For replacement water filters, visit Breville.com or contact Breville Customer Service.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

Operation

  1. Ensure the water tank is in place and that the water filter cartridge is correctly fitted into position.
  2. Plug into a 230/240V power outlet. The unit will sound a long beep and the water droplet light will flash 3 times to indicate the unit is in standby mode.
  3. Remove the water tank and fill with cold tap water to the MAX level. Never fill past the MAX level.
  4. Ensure the water tank is assembled to the unit correctly and place a cup of choice onto the drip tray, or alternatively, remove the drip tray to accommodate large glasses.

BREVILLE the AquaStation Chilled LWA300 - Operation - 1

NOTE

Always ensure the water tank is filled to the MAX level for optimum flow of water from the spout. Ensure the water tank is filled above MIN water level, or as soon as the water droplet light on the START/STOP button will turn to solid red.

If the water level falls below the MIN tank marking, the water sensor will automatically stop dispensing and The water droplet light on the START/STOP button will illuminate solid red.

Regularly check and discard any water that might accumulate in the drip tray.

TURNING OFF THE Unit

Turn off at the power outlet.

BREVILLE the AquaStation Chilled LWA300 - TURNING OFF THE Unit - 1

IMPORTANT

Turning the unit off at the power outlet will delete the 'last setting' memory function.

BREVILLE the AquaStation Chilled LWA300 - IMPORTANT - 1

NOTE

Discard any filtered water that has been left sitting for several days or more. This will ensure you have cleaner, great-tasting water. If your filter has been unused for a long period of time, it is recommended to resoak the filter for 10 minutes before use and clean the water tanks as per the cleaning instructions found in this book.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

WARNING

To prevent damage to the compressor and to ensure maximum performance, place unit in an upright position for 12 hours after transit.

STANDBY MODE

When the unit is plugged into the power outlet, the unit will sound a long beep and the water droplet light will flash 3 times to indicate the unit is ready for use.

The unit will automatically enter energy saving standby mode after 5 minutes if not used. The control panel indicator lights will turn off except for and READY to indicate the compressor is still working.

To awaken the unit, press the START/STOP button once; one long beep will sound, the water droplet light will illuminate white and flash rapidly 3 times to indicate that the unit is ready to use.

Ambient Water in Operation

  1. Turn the FUNCTION dial to AMBIENT, press the START/STOP button to instantly dispense filtered ambient water. Press START/STOP button once more to stop dispensing water. The water droplet will illuminate solid white during water dispensing.

BREVILLE the AquaStation Chilled LWA300 - Ambient Water in Operation - 1

NOTE

If the START/STOP button is not pressed a second time to stop, dispensing will automatically stop after 60 seconds.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

Always ensure the correct sized cup/glass is placed under the spout to collect the selected volume of dispensed water.

COLD Water in Operation

  1. Turn the FUNCTION dial to your desired temperature, press the START/STOP button once. The Cooling LED light will illuminate to indicate that the compressor is on and is reaching the set temp.
  2. Once the unit has reached the set temp, the READY LED light will illuminate white.
  3. The unit is now ready to dispense filtered chilled water at the set temperature.
  4. Press START/STOP
  5. button and the unit will start dispensing filtered cold water, and the water droplet icon will illuminate white while water is dispensing.

BREVILLE the AquaStation Chilled LWA300 - COLD Water in Operation - 1

NOTE

START/STOP button can be pressed to dispense water before the unit reaches the set temperature, however, the water dispensed will not be at the set temperature.

  1. Once the desired amount of water has been dispensed, press START/STOP button again to stop dispensing. The unit will beep, the water droplet light will turn off and the unit will return to standby mode.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

If the START/STOP button is not pressed a second time to stop, dispensing will automatically stop after 60 seconds.

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

NOTE

Always ensure the correct sized cup/glass is placed under the spout to collect the selected volume of dispensed water

BREVILLE the AquaStation Chilled LWA300 - NOTE - 1

Care, Cleaning & Storage

BREVILLE the AquaStation Chilled LWA300 - Care, Cleaning &amp; Storage - 1

CAUTION

To prevent damage to the appliance, do not use alkaline or abrasive cleaning agents, steel wool or scouring pads as these can damage the surface of the unit. Do not place any part of this appliance in the dishwasher.

CLEANING THE AQUASTATION

  1. Remove the plug from the power outlet before cleaning.
  2. Discard any water in the water tank, then remove the filter cartridge from the filter holder.
  3. Wipe the water tanks with a clean, damp, lint-free cloth. The filter is not washable.

CLEANING THE OUTER HOUSING

  • Wipe with a soft, damp cloth followed by a soft, dry cloth to polish.
    • Alternatively, purchase a stainless steel cleaner such as Breville's Stainless Steel Cleaner & Polish and follow directions.
  • Do not use abrasive cleansers, pads or cloths which can scratch the surface.

BREVILLE the AquaStation Chilled LWA300 - CLEANING THE OUTER HOUSING - 1

NOTE

For Breville's Stainless Steel Cleaner & Polish, visit Breville.com or contact Breville Customer Service.

CLEANING THE WATER SPOUT

Residue build-up or foreign substances, such as dust or lint, may accumulate in the water outlet. Clean the spout periodically using a soft brush (not included).

EMPTYING THE INTERNAL 2L CHILLING CHAMBER

  1. To completely empty the internal 2L chilling chamber before storing, turn off and unplug the unit from the power outlet.
  2. Remove and empty the removable external 6L water tank.
  3. Place the unit on sink drain board ensuring the power cord & power plug are not immersed in any water, unscrew the plastic drain plug cap (refer to figure a) located underneath the unit, then pull out the rubber plug (refer to figure b), allow water to drain from the internal 2L chilling chamber.

BREVILLE the AquaStation Chilled LWA300 - EMPTYING THE INTERNAL 2L CHILLING CHAMBER - 1

text_image Technical diagram showing mechanical assembly with labeled parts A and B, including directional arrows indicating movement or flow.
  1. Replace the rubber plug (refer to figure c) and screw the plastic drain plug cap back on (refer to figure d).

BREVILLE the AquaStation Chilled LWA300 - EMPTYING THE INTERNAL 2L CHILLING CHAMBER - 2

text_image ↑c1 D
  1. Wipe the water the base of the unit with a clean, dry, lint-free cloth.

CLEANING THE DRIP TRAY

The drip tray should be removed, emptied and cleaned after each use. Empty the tray before removing the top grill and cleaning.

  1. Remove the drip tray from the unit and discard any water.
  2. Separate the top grill from the drip tray.
  3. Wash the drip tray and grill in warm soapy water and dry thoroughly.
  4. Place the grill back onto the drip tray then push the assembled drip tray back into position in front of the unit using the magnetic connection.

BREVILLE the AquaStation Chilled LWA300 - CLEANING THE DRIP TRAY - 1

WARNING

To protect against electric shock, do not immerse cord, plug or unit in water or any other liquid or allow moisture to come into contact with these parts.

STORAGE

Remove the plug from the power outlet. Follow the 'Care & Cleaning' instructions, ensuring the unit is completely empty, clean and dry before storing. Stand the unit upright. Do not store anything on top. If stored for a long period, we recommend following the 'Flushing the AquaStation™' and 'Preparing the Activ360 Filter' instructions found in this book before using the unit again.

BREVILLE the AquaStation Chilled LWA300 - STORAGE - 1

WARNING

The water dispenser contains a compressor that MUST remain upright at all times. Do not store the unit on any other surface apart from its feet.

PROBLEM POSSIBLE CAUSE WHAT TO DO

Slow water flow rate·Aging of pump or inlet at the base of the unit is clogged·Contact Breville Customer Service
Small amounts of black particles in water tank·These are small pieces of carbon from the filter. These carbon particles are food grade and are not harmful. They will not impair the performance of your filter or unit.·Flush your unit and water filter cartridge. Refer to ‘Flushing the Breville AQUASTATIONTM’ (page 12) and ‘Preparing the Activ360 Filter’ (page 12)NOTE: Some carbon fibre residual may still be present after flushing the unit and filter.
START/STOP Button does not respond·The unit is not connected to the power·Plug in to a usable power outlet and turn power on
Leakage from water tank·The water tank is filled beyond the maximum water level·Tank is not firmly pushed into position·Ensure water is only up to the MAX water level marking. If leakage continues, please contact Breville Customer Service·Replace the water tank, pressing down to ensure that it is properly positioned and attached to the unit.
Odd taste of the water·The filtered water has not been used for a long time·The filter has reached end of life·Discard the remaining water in the water tank and refill with fresh tap water. Depending on the length of time, the filter may require re-flushing·Replace with new filter
“FILTER RESET” Indicator light flashing·Filter needs to be changed or filter reset has not been actioned·Change the filter if required, turn the FUNCTION dial to “FILTER RESET” and press the START/ STOP button once to reset.

If you cannot remedy problems by using the troubleshooting chart above, contact Breville Customer Service.

Breville Customer Service Centre

Australian Customers

New Zealand Customers

Phone: 1300 139 798

Phone: 0800 273 845

Web: www.breville.com

Web: www.breville.com

Breville®

Master Every Moment™

Breville, the Breville logo, AquaStation and Activ360 are trademarks of Breville Pty Ltd. All other brands may be trademarks of their respective owners. Breville's products are distributed in New Zealand under licence A.B.N. 98 000 092 928.

Approved by the appropriate electrical supply authorities.

Made in China to our specifications.

Due to continued product improvement, the product illustrated on this carton may vary slightly from the actual product.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BREVILLE

Model : the AquaStation Chilled LWA300

Category : Water dispenser