This plate operates on natural gas G20/G25 (20/25 mbar) by default. Here are the specifications of the injectors (nozzles) for each burner:
- Auxiliary: diameter 73/100 mm, reduced flow 380 W
- Semi-fast: diameter 92/100 mm, reduced flow 380 W
- Medium fast: diameter 115/100 mm, reduced flow 650 W
- Large fast: diameter 126/100 mm, reduced flow 750 W
- Fish cooker: diameter 100/100 mm, reduced flow 750 W
- Ultra-fast: diameter 130/100 mm, reduced flow 1200 W
- Double crown (internal): diameter 67/100 mm, reduced flow 380 W
- Double crown (external): diameter 130/100 mm, reduced flow 1200 W
If you are using butane or propane (G30/G31 at 28/37 mbar), you will need to replace these injectors with others specific to these gases. Replacement injectors are provided with the appliance in a separate bag.