Product Type Electric twin breast pump
Model Philips AVENT SCF316
Power Supply AC adapter (included) or 4 x 1.5V AA batteries (not included)
Operating Modes Stimulation mode (2 levels) and Expression mode (4 levels)
Timer Up to 99 minutes; auto shut-off at 100 minutes
Included Accessories 2x pump bodies, 2x bottles (125ml), 2x teats (0m+), 2x screw rings, 2x sealing discs, 2x caps, 3x silicone diaphragms, 2x massage cushions, assembly tool, travel covers, breast pad, silicone tube, power adapter
Material Plastic (PP), silicone
Cleaning Dishwasher safe (top rack) or hand wash; sterilize by boiling 5 min or steam sterilizer
Motor Unit Cleaning Wipe with soft cloth; do not submerge in water
Safety Features Auto shut-off after 30 min inactivity; pause function; anti-scald protection
Compatibility Compatible with Philips AVENT bottles and teats
Warranty 2 years (motor and power adapter only)
Dimensions (Motor Unit) Approx. 10 x 6 x 12 cm (estimated)
Weight Approx. 200 g (motor unit only, estimated)
Battery Life Varies with usage; rechargeable batteries recommended
Expression Kit Natural suckling kit with massage cushion and silicone diaphragm

Frequently Asked Questions - AVENT SCF316 PHILIPS

How do I clean and sterilize the breast pump for the first time?
Disassemble all parts that contact milk (bottles, teats, pump bodies, diaphragms, massage cushions, valves). Wash in warm soapy water or top rack dishwasher. Then sterilize by boiling for 5 minutes or using a steam sterilizer. Do not sterilize the motor, silicone tube, cap, or power adapter.
Can I use the pump with batteries?
Yes, open the rear cover and insert 4 x 1.5V AA alkaline or rechargeable batteries. Note: the pump will use mains power if the adapter is plugged in, and batteries cannot be charged in the unit.
Why is there no suction?
Check assembly: ensure the massage cushion is locked to the funnel end, the valve is correctly positioned, and the silicone tube is firmly connected to the cap and motor. Also verify the cap and diaphragm create a perfect seal. If the problem persists, inspect for damage.
How do I pause pumping?
Press the pause/play button during pumping. The display will flash. Press again to resume with the same mode and level. Only the pause and power buttons work during pause.
Can I express from one breast only?
Yes. Disconnect one silicone tube from the cap and insert it into the connecting hole on the motor, or simply remove the pump from the other breast. The operation is the same as dual expression.
How do I store expressed breast milk?
Pour milk into sterilized Philips AVENT bottles, seal with a sealing disc or teat. Refrigerate for up to 48 hours (not in the door) or freeze for up to 3 months. Label with date and time. Never refreeze thawed milk.
What should I do if pumping is painful?
Stop immediately and consult a healthcare professional. You may be using too high a suction level; try lowering it with the level down button. Ensure the pump is positioned correctly and the massage cushion creates a seal without pinching.
How do I replace the silicone diaphragm?
If the diaphragm is damaged or broken, disassemble the pump body and remove the old diaphragm. Insert a new one (spare included) and press the rim to ensure a perfect seal. Replacement diaphragms are available from Philips AVENT.
Can I share the breast pump with another mother?
No. The parts that come into contact with milk are personal care items and should not be shared due to hygiene reasons. Only the motor unit may be shared if all milk-contact parts are replaced.
How do I keep the pump sterile for travel?
After sterilizing and assembling all parts (valve, massage cushion, diaphragm, cap) on the pump body, attach the pump cover and screw on the travel cover. This maintains sterility during transport.

User questions about AVENT SCF316 PHILIPS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Breast Pump in PDF format for free! Find your manual AVENT SCF316 - PHILIPS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AVENT SCF316 by PHILIPS.

USER MANUAL AVENT SCF316 PHILIPS

natural_image Product photo of a medical device with Philips AVENT-branded pump, showing internal components and no visible text or symbols.

Table of Contents

1Important 4 Electromagnetic Fields (EMF) 6
2Introduction 6 Overview 7 Control panel 8
3Cleaning and Sterilising 9
4Assembling 9
5Using your pump 12 Before using the pump 12 To begin pumping 13 To pause pumping 16 Storing your breast milk 17 Feeding your baby with expressed breast milk 17 Keeping your breast pump sterile for travel 18
6Hints to help you succeed 18
7When to express milk 19 Right times of the day to express your milk 19
8Storage 19

1 Important

Read this user manual carefully before using your Philips Avent twin electronic breast pump, and save the user manual for future reference. You can also find this user manual at Philips website: www.phllips.com/support.

Warning

• Always unplug from the power socket immediately after use.
- Do not use the breast pump while bathing.
- Do not place or store the breast pump where it can fall or be pulled into a bath or sink.
- Do not place or drop the pump motor, silicone tube, and power adapter into water or other liquids.
- Do not reach for a product that has fallen into water. Unplug from the power socket immediately.
• Children should be supervised to ensure that they do not play with the appliance. Place the appliance out of reach from children and pets.
- Before each use, check the breast pump, including the power adapter for signs of damage. Never operate the breast pump if it has a damaged plug, not working

  • The power cord is irreplaceable. Discard it if is damaged,
    including the power adapter.
  • Only use accessories recommended by Philips Avent.
  • Only use the power adapter supplied with the product.
    • Make sure the breast pump, including the power adapter, is not exposed to extreme heat or placed in direct sunlight.
  • Do not use the breast pump outdoors.
    • There are no user serviceable parts inside the pump. Do not attempt to open, service, or repair the breast pump yourself.
    • The parts of the pump which come directly into contact with milk are personal care items, and should not be shared between mothers.
  • Do not attempt to remove the pump body from the breast while under vacuum. Switch the breast pump off, and break the seal between your breast and the pump funnel with your finger, then remove the pump from your breast. You can also pull off the silicone tube from the motor or the cap to release the vacuum.
  • Never use while pregnant as pumping can induce labor.
  • Never use when sleepy or drowsy.

been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved.

• This appliance shall not be used by children.
- If expressing becomes painful, stop and consult your breast feeding advisor or healthcare professional.
- Do not use the breast pump in the presence of flammable anaesthetic mixtures with air, with oxygen, or with nitrous oxide.
- Although the breast pump is compliant with applicable EMC directives, it may still be susceptible to excessive emissions and/or may interfere with more sensitive equipment.
- Make sure not put any products on the pump motor, like pillow, blanket etc. Please make sure pump motor work in well ventilation and heat dissipation condition.

Caution

  • The product should not be left unattended when plugged into a power socket.
  • Never drop or insert any foreign object into any opening or the silicone tube.
  • Do not shorten the silicone tube.
    • Before you connect the breast

  • Wash, rinse, and sterilise the appropriate pump parts before each use.

  • Do not use antibacterial, abrasive cleaners, or detergents when cleaning breast pump parts.
  • Never put the breast pump motor in water or steriliser, as you can cause permanent damage to the pump.
  • If the vacuum generated is uncomfortable or cause pain, switch off the breast pump, break the seal between the breast and the pump funnel with your finger, and then remove the pump from your breast. You can also pull off the silicone tube from the motor or the cap to release the vacuum.
  • Do not continue pumping for more than five minutes at a time if no result is achieved.
  • Never use any accessories or parts from other manufacturers or that Phillips Avent does not specifically recommend. If you use such accessories or parts, your guarantee becomes invalid
  • Do not use the breast pump if the silicone diaphragm appears to be damaged or broken. Replace the silicone diaphragm. See chapter "Guarantee and service" for information on how to obtain replacement parts.

Maturing feeding tests on

prolonged bite will damage the teat. For hygiene reasons, replace teats after three months of use. Use only Philips Avent teats and bottles together.

Batteries

This appliance can use both 15V AA non-chargeable batteries and rechargeable batteries. For instructions on how to replace the batteries see chapter 'Assembling'.

  • Rechargeable batteries are to be removed from the appliance before being charged.
  • Different types of batteries or new and used batteries are not to be mixed.
  • Batteries are to be inserted with the correct polarity.
  • Exhausted batteries are to be removed from the appliance and safely disposed of.
    • If the appliance is to be stored unused for a long period, the batteries should be removed.
    • The supply terminals are not to be short-circuited.
    • Non-rechargeable batteries are not to be recharged.

Electromagnetic Fields (EMF)

This Philips appliance complies with all applicable standards and

2 Introduction

Congratulations on your purchase and welcome to Philips Avent! To fully benefit from the support that Philips Avent offers, register your product at www.philips.com/ welcome.

The philips Avent breast pump provides comfort, convenience for effective expression. It has an "Natural suckling" expression kit, an innovative funnel to mimic natural suckling and compress your nipple and areola, to make whole expression more comfortable and effective. Rhythmic Wave mimics the fast/shallow & slow/deep way a baby suckles for faster let down and continuous milk flow with closer to natural sucking pacing.

Doctors recommend that breast milk is the best nutrition for babies during the first year, combined with solid food after the first six months. Your milk is specially adapted to your baby's needs and contains antibodies which help protect your baby against infection and allergies. Your electric breast pump will help you breast-feed longer. You can express and store your milk so that - whether you are out for a few hours, taking a well deserved rest, or back at work - your baby can still enjoy the benefits of your breast milk, even if you cannot be there to

Overview
Labeled diagram of a medical or laboratory device with numbered parts for identification and assembly reference.

1Silicone tube 10 Screw ring (x2)
2Cap (x2) 11 Teat (x2) (0m+)
3Silicone diaphragm (x3) (one for back up)12Sealing disc (x2)
4Pump body (x2) 13 Breast pad
5Massage cushion (x2) 14 Bottle (x2) (125ml)
6Assembly tool 15 Travel cover (x2)

Control panel
A B C D E F G PHIOPS AVENT M L K J I H

A Timer counting indicator H Level up button
B Stimulation indicator I Pause/play button
C Level 2 indicator J Level 4 indicator
D Level 1 indicator K Level 3 indicator
E Mode selection button (selecting the stimulation and expression mode)L Expression Indicator
F Level down button M Battery indicator
G Power button

PHILIPS AVENT SCF316 - Introduction - 3

Note

The battery indicator flashes only when in low battery. We recommend you to choose the battery as well as possible.

3 Cleaning and Sterilising

Before you use your breast pump for the first time and for every time, you must disassemble, wash, and sterilise all the breast pump parts that come into contact with your breast milk. (see ③ ④ ⑤ ⑥ ⑦ ⑧ ⑪ ⑮ in Overview chapter) Before you use the bottle and its parts for the first time and for every time, you must also disassemble, wash and sterilise. (see ⑨ ⑩ ⑪ ⑫ in Overview chapter)

! Caution

Never wash or sterilise the pump motor, the silicone tube, the cap, and the power adapter. These components do not come into contact with your breast milk. You can wipe those parts clean with a soft cloth.

You can also use the dishwasher (top rack only) or hand wash in warm, soapy water, and then rinse thoroughly. We recommend you to sterilise all the parts contacting with breast milk in our Phillips Avent steam steriliser, or by boiling for 5 minutes. Avoid to contact with the vessel directly to protect the parts from deformation.

Caution

•Take care when cleaning the valve and the silicone diaphragm. If it gets damaged, your breast pump will not function properly.

• To clean the valve, rub it gently between your fingers in warm soapy water. Do not insert objects as this may cause damage.

4 Assembling

To assemble the pump, follow the steps below.

Note

• Make sure that you clean and sterilise the pump as instructed in this user manual.

• Make sure that you assemble the pump correctly as instructed in this user manual.

• To avoid leakage, remove the residue around the rim before assembling. Put the bottle onto the pump body, and do not over-tighten.

Wash your hand thoroughly before you take sterilised components.

1 Insert the valve into the pump body from underneath.

PHILIPS AVENT SCF316 - Note - 1

2 Put the bottle onto the pump body and turn it anticlockwise to fix it. Do not over-tighten when assembling the bottle to the pump body.

PHILIPS AVENT SCF316 - Note - 2

3 Insert the massage cushion into the pump funnel and press the rim to ensure a perfect seal.

PHILIPS AVENT SCF316 - Note - 3

4 You can press the end of the massage cushion with assembly tool to help it lock to the line indicated by the arrow on the end-position of the funnel.

PHILIPS AVENT SCF316 - Note - 4

PHILIPS AVENT SCF316 - Note - 5

Caution

To ensure the effect of pumping, make sure that the end of the massage cushion is properly locked to the line indicated by the arrow on the end-position of the funnel.

PHILIPS AVENT SCF316 - Note - 6

PHILIPS AVENT SCF316 - Note - 7

PHILIPS AVENT SCF316 - Note - 8

5 Put the silicone diaphragm onto the pump body and press the rim to make sure a perfect seal.
Diagram showing two-step hair cleaning process: first step with brush, second step with tool

PHILIPS AVENT SCF316 - Note - 10

Tip

You may find it easier to assemble while it is wet.

6 Firmly push the cap onto the silicone diaphragm, so that it sites securely on top of the silicone diaphragm.

PHILIPS AVENT SCF316 - Tip - 1

7 Repeat above steps 1-6 for another pump body.

8 Connect the silicone tube to the cap and the motor firmly.

PHILIPS AVENT SCF316 - Tip - 2

PHILIPS AVENT SCF316 - Tip - 3

9 Connect the power adapter to the pump motor, and then insert the power plug to the power socket.

PHILIPS AVENT SCF316 - Tip - 4

PHILIPS AVENT SCF316 - Tip - 5

Note

Only use the adapter provided with this product. Do not use other adapter.

PHILIPS AVENT SCF316 - Tip - 6

Tip

For battery operation, open the rear cover of the motor unit in the direction indicated by the marks. Insert four new 15V AA alkaline batteries into the battery housing(We do not recommend to use carbon-zinc batteries). Reattach the rear cover to the motor unit. We recommend you to use rechargeable batteries for long time use.

PHILIPS AVENT SCF316 - Tip - 7

PHILIPS AVENT SCF316 - Tip - 8

Note

• If you have inserted batteries in the battery housing of the pump motor and plug in the adapter, the breast pump will run from the main power supply. The batteries cannot be charged in the unit.

5 Using your pump

Before using the pump

Wash your hands thoroughly, and make sure your breasts are clean. Gently squeeze a little milk from each nipple to make sure that milk ducts are not blocked. Make sure you follow the steps in "Cleaning and sterilising" and "Assembling" chapters to clean, sterilise, and assemble the breast pump.

To begin pumping

1 Press the assembled pump bodies against your breasts. Make sure that your nipples are centered, so that the massage cushion creates an airtight seal. Make sure that no air escapes; otherwise there is no suction.

PHILIPS AVENT SCF316 - To begin pumping - 1

2 Press the power button ( ) to switch on your pump.

PHILIPS AVENT SCF316 - To begin pumping - 2

→ The display panel lights up for 1 second. The breast pump automatically starts up in stimulation level 1 mode in the first time usage, and the stimulation indicator lights up. The appliance has the memory function to remember the levels for

→ You begin to feel the suction on your breast and the massage of the massage cushion on your nipple.

Note

The timer starts when the appliance is power on. The timer indicator displays 01 after the appliance has been power on for 1 minute. The unit is minute. The timer will show total breast pumping time, pause time does not count in. If the timer displays over 99 minutes (when it comes to 100 minutes), the machine will shut down automatically.

3 You can choose your desired stimulation level to stimulate milk by pressing the level up (and level down buttons). You can press the level up button to deepen the suction. Press the level down button to lower the suction. There are altogether stimulation levels.

PHILIPS AVENT SCF316 - Note - 1

4 Once your milk starts flowing, you can press the mode selection button (①to switch to the expression mode.

PHILIPS AVENT SCF316 - Note - 2

5 After switching to the expression mode, you can choose your desired expression level by pressing the level up (and level down buttons. You can press the level up button to deeper the suction. Press the level down button to lower the suction. There are altogether 4 expression levels.

Image showing two sets of icons with symbols and percentages, possibly representing UI elements or status indicators.

→ The expression indicator lights up instead of the stimulation indicator.

Note

- Do not worry if your milk does not flow immediately. Relax and continue pumping.

Do not continue pumping for more than 5 minutes at a time if you do not succeed in expressing any milk. Try to express at another time during the day.

• if the process becomes very uncomfortable or painful, stop using the pump and consult your breast feeding advisor.

Stimulation and expression levels match to the number of the flowers lighting up. That is, 1 flower lighting up means level 1, and 2 flowers lighting up means level 2.

When needed, you can also use stimulation mode to do expression.

6 During expression, you can switch between the stimulation mode and expression mode by pressing the mode selection button (①) for better expression.

PHILIPS AVENT SCF316 - Note - 1

PHILIPS AVENT SCF316 - Note - 2

Note

You do not need to use all stimulation/expression levels, only use the levels that are comfortable for you.

Place the pump motor on a stable and flat surface, to avoid any accidental drops when in use. If not, this may pull the pump body off from the breast and cause injury.

7 The twin electric breast pump enables you to express milk from both breasts at the same time. However, you can also use the appliance to express from one breast. To express from one breast, you need to disconnect one silicone tube from the cap, and insert it into the connecting hole, or you can take the pump from one breast. Other operations are just in the same way.

PHILIPS AVENT SCF316 - Note - 1

natural_image Medical illustration showing anatomical structures with no visible text or symbols

PHILIPS AVENT SCF316 - Note - 2

Note

• If you regularly express more than 125ml per session on each breast, you can use a 260ml/9fl oz Philips Avent bottle to prevent overfilling and spillage.

• If there is no operation on this appliance (such as pause, change stimulation level and expression level) for 30 minutes (including in pause), the appliance will shut down automatically

8 When you have finished expressing, press the power button (①) to switch off the breast pump and carefully remove the pump body from your breast.

PHILIPS AVENT SCF316 - Note - 1

Tip

After switching off the breast pump, break the seal between the breast and the pump funnel with your finger, and then remove the pump from your breast.

9 Disconnect the power plug to the power socket, and then disconnect the power adapter from the pump motor.

PHILIPS AVENT SCF316 - Tip - 1

PHILIPS AVENT SCF316 - Tip - 2

Tip

In order to protect the appliance, please always shut down the appliance by pressing the power button instead of plugging off.

10 Unscrew the bottles from the pump bodies ready for feeding/storage. Clean the other used parts of the breast pump according to the instructions in chapter 'Cleaning and sterilising'.

PHILIPS AVENT SCF316 - Tip - 1

Caution

Never tilt the breast pump when the milk has reached the maximum line on the bottle. Replace with a new bottle before re-pumping to avoid spillage.

After expression, please take off the bottle from pump body immediately, then store the bottle with sealing disc.

To pause pumping

This breast pump has a pause function, and you can press the pause button (4) to pause pumping if at any time the suction becomes uncomfortable, there is a need to change the bottle, reposition the pump on the breast, or a short rest.

1 When the breast pump is in a particular stimulation or expression mode, press pause button (which will pause the pumping.

→ The timer indicator, level indicator, and stimulation/expression indicator will flash to remind you of the pausing status.

PHILIPS AVENT SCF316 - To pause pumping - 1

PHILIPS AVENT SCF316 - To pause pumping - 2

Note

When the breast pump is in pause, level down/level up button and stimulation/expression switch mode button will lose their functions. Only pausing button and power button still work.

2 Press the pause button () again to continue the pumping with the stimulation or expression mode selected before pausing

Storing your breast milk

Caution

Never refreeze breast milk. Do not mix fresh breast milk to already frozen milk. Always discard any left over milk at the end of a feed.

Note

Only store breast milk collected with a sterile pump.

1 After you have expressed your milk, unscrew the pump bodies from the Philips Avent bottles.

2 Store expressed milk in cleaned and sterilised Philips Avent bottles fitted with sealing discs. Put them in the fridge or freezer immediately

  • You can store expressed breast milk in the refrigerator for up to 48 hours (not in the door) or in the freezer for up to 3 months.
  • Label the bottles with date and time.
    • Use up the older milk first.

PHILIPS AVENT SCF316 - Note - 1

Philips Avent Natural Bottle provides:

Natural latch on. The wide breast shaped teat makes it easy for your baby to combine breast and bottle feeding. Unique comfort petals. Petals inside the teat increase softness and flexibility without teat collapse. Advanced anti-colic valve. Innovative twin valve design reduces colic and discomfort by venting air into the bottle and not baby's tummy.

Feeding your baby with expressed breast milk

If you use Philips Avent bottle to store breast milk, make sure to remove the sealing disc and assemble the Philips Avent teat for feeding.

PHILIPS AVENT SCF316 - Feeding your baby with expressed breast milk - 1

Place the frozen breast milk in the refrigerator to defrost overnight. In case of an emergency, you

About heating up the breast milk: Heat the bottle with in a bowl of hot water, or using Philips Avent bottle and baby food warmer to safely heat up the milk.

! Caution

Remember! Always check milk or food temperature before feeding. Never heat breast milk in a microwave as this may destroy valuable nutrients and antibodies. In addition, the uneven heating may cause hot spots in the liquid which could cause burns to the throat. Never immerse a frozen bottle in boiling water to avoid crack or split.

Keeping your breast pump sterile for travel

After sterilising all parts, please refer to steps in "Assembling" to assemble the valve, massage cushion, diaphragm and diaphragm cap on the pump body, then put on the pump cover and screw on the travel cover, which can keep your breast pump sterile for travel.

PHILIPS AVENT SCF316 - Keeping your breast pump sterile for travel - 1

6 Hints to help you succeed

The twin electronic breast pump is easy to use. Take some practice, and you will soon get used to expressing milk.

Choose a time when you are not rushed nor interrupted easily. Having your baby or a photograph of your baby nearby can help encourage your milk to flow. Before expressing milk, place a warm towel onto your breast, and lightly massage for a few minutes. This encourages milk flow, and ease the pain of your breast. Warmth and relaxation can encourage milk flow. Try expressing after a warm bath or shower. Try expressing from one breast while your baby is feeding from the other, or continue expressing just after a feed. Repositioning the pump on the breast from time to time can help stimulate your milk flow

Tip

•Practice with your pump to find the best pumping techniques for you. If the process becomes painful, stop and consult your

1 Open the package and take out the breast pad.

PHILIPS AVENT SCF316 - Tip - 1

flowchart
graph TD
    A["Raw Produce"] --> B["Processed Food"]
    B --> C["Processed Food"]

2 Remove the sticker and put breast pad in the bra as picture showed, stick it on bra to avoid movement.

PHILIPS AVENT SCF316 - Tip - 2

natural_image Illustration of two hands performing a medical or therapeutic procedure, showing a hand holding a tool and another pointing to a device (no text or symbols present)

the pain, and to help your baby latch on more easily.

If you have sore or cracked nipples and you may wish to express your milk until they are healed.

If you are separated from your baby and wish to continue to breast-feed when you are reunited. You should express your milk regularly to stimulate your milk supply.

Right times of the day to express your milk

Early in the morning when you breasts are full, just before or after your baby's first feed.

After a feed, if your baby has not emptied both breasts.

Between feeds or in a break if you have returned to work.

7 When to express milk

If possible, wait until your milk supply and breast-feeding schedule are well established, unless told otherwise by your doctor or breast-feeding advisor.

The exceptions are: • If you are expressing milk for your baby to be given in hospital.

8 Storage

Keep the breast pump out of direct sunlight as prolonged exposure may cause discoloration.

Store the breast pump and its accessories in a safe and dry place.

9 Compatibility

The Philips Avent electric breast pump is compatible with Philips Avent bottles in our range. When you use other Philips Avent bottles, use the same type of teal that was supplied with that bottle. For details on how to assemble the teal and general cleaning instructions, refer to the user manual on our website, www.philips.com/support.

10 Ordering accessories

To purchase accessories for this appliance, please visit our online shop at www.shop.phillips.com/service. If the online shop is not available in your country, go to your Philips dealer or a Philips service centre. If you have any difficulties obtaining accessories for your appliance, please contact the Philips Consumer Care Centre in your country. You find its contact details in the worldwide guarantee leaflet.

11 Recycling

Do not throw away the product with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment.

Follow your country's rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.

12 Guarantee and service

Philips guarantees its products under correct usage for a period of two year after the date of purchase. If any defect due to faulty materials and workmanship occurs within this two year guarantee period, Philips will repair or replace the product at its expense. For repair or replacement, make sure to provide convincing proof, for instance by means of a receipt, that the day on which service is claimed is within the guarantee period. The guarantee only covers the breast pump motor and power adapter. It does not cover non-electrical parts, accessories and consumable parts. The guarantee does not cover shipping and handling fees, and on-site services fees either. If you need service or information, or if you have a problem, please contact the Philips Avent Consumer Care center. Website: http://www.phillips.com/support

13 Troubleshooting

This chapter summarises the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, contact the Consumer Care Centre in your country or visit us online at www.philips.com/support.

Problem Solution

Lack of suction. Check that all components are assembled correctly and that the valve is in positioned correctly.Make sure that the massage cushion is locked to the end-position of the funnel.Make sure that the cap, the diaphragm, and the massage cushion are filled securely to the pump body and a perfect seal is created.The air pressure in your region is too low, this may affect the suction.Make sure the silicone tube is firmly connected to the cap and the motor, without twisting.
No milk being expressed.Make sure the pump is assembled correctly, and the suction is created.Relax and try again, as expression may improve with practice.Refer to the "Hints to help you succeed" section.
Pain in the breast area when expressing.You may be pumping too hard. You do not need to use all the suction that the pump can generate but the comfortable levels. Press the level down button to lower down the suction intensity.Consult your health professional/ breast feeding advisor.
Milk is leaking out from the massage cushion or remaining on the cushion.Remove and rech the massage cushion. Make sure that it is installed correctly and firmly.Do not lean backward in excess when pumping.

Problem Solution

Cracking/Discoloring· Avoid contact antibacterial or abrasive detergents/cleaners. Combinations of detergents, cleaning products, sterilisation solution, softened water, and temperature fluctuations may cause the plastic to crack. If any crack is found, stop using the pump immediately. Contact Philips Avent Consumer Care center for spare components.· Food coloring can discolor components, but this will not affect your usage.· Keep all the components away from the source of heat or direct sunlight as it can discolor components.
Components are broken or lost.· Contact Philips Avent Consumer Care center for spare components. See back cover for contact details.
Pump does not response.· Make sure the pump is correctly assembled and press the power button to switch on.· Make sure the cables between the pump and the power socket are correctly connected.
Pump motor display flashes. 3 seconds, then shuts down automatically.· When using the power adapter to supply power, make sure you are using the one Philips provided. Then make sure it is connected properly, then switch the pump on again.· If you use batteries to supply power, press the power button to switch off. Replace with new batteries and switch the pump on again.· After checking the 2 scenarios above, if the problem persists, contact the Consumer Care center for help

The silicone tube is too loose when it is plugged into machine or cap.
- Change the new back up silicone tube connector

14 Important additional information

There are some common breast feeding-related symptoms described in the table below. If you experience any of these symptoms, contact a healthcare professional or breast feeding specialist.

Symptom
Pain sensation • Perceived pain in breast or nipple.
Sore nipples • Persistent pain in the nipples at the beginning of the pumping period, or that lasts throughout the entire pumping period, or hurts between sessions, very similar to the pain felt during breast feeding.
Engorgement • Swelling of the breast. The breast may feel hard, lumpy and tender.May include erythema (redness) of the breast area and fever.
Bruise, thrombusA reddish-purple discoloration that does not blanch when pressed. When a bruise fades, it becomes green and brown.
Blistering • Looks like small bubbles on the surface of the skin.
Injured tissue on nipple (nipple trauma)Fissures or cracked nipples.Skin tissue peeling off the nipple. Normally occurs in combination with cracked nipples and/or blisters.Nipple tear.
Bleeding • Cracked or teared nipples can lead to bleeding of the affected area.
Clogged mammary ductsA red, tender lump on the breast. May include erythema (redness) of the breast area and fever. Can lead to Maslitis (breast inflammation) if left untreated.

目录

www.philips.com/support

警告

1硅橡胶管组件10螺旋盖(x2)
2硅橡胶隔膜盖(x2)11奶嘴(x2)(0个月以上,一孔)
3硅橡胶隔膜(x3)(另一配件备用)12密封垫(x2)
4吸乳器主体(x2)13防溢乳垫
5按摩软垫(x2)14奶瓶(x2)(125毫升)

控制面板
A B C D E F G PHIOPS AVENT M L K J I H

PHILIPS AVENT SCF316 - 警告 - 2

提示

natural_image Line drawing of a medical or laboratory procedure setup with two spray bottles and a central device (no text or symbols)

PHILIPS AVENT SCF316 - 提示 - 1

注意

natural_image Illustration of two hands performing a medical procedure on a patient's abdomen, showing a finger placement (no text or symbols present)

7 吸乳的合适时间

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PHILIPS

Model : AVENT SCF316

Category : Breast Pump