Thor

HRH3004U - Range hood Thor - Free user manual and instructions

Find the device manual for free HRH3004U Thor in PDF.

📄 22 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Thor HRH3004U - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Range Hood
Brand Thor
Model HRH3004U
Dimensions (Approx.) 30" Width
Power Requirements 110-120V / 60Hz
Duct Size 7" Round (Vertical)
Fan Speeds 4 Speeds: Quiet (F1), Low (F2), Medium (F3), High (F4)
Control Type Touch Sensor with Remote Control
Lighting 2 x LED Bulbs (12V / 1.5W)
Filter Type Stainless Steel Baffle Filters (2 pcs)
Grease Tray 2 Stainless Steel Grease Boxes
Time Delay Function Yes, up to 15 minutes
Automatic Sensor Control Yes
Installation Type Under Cabinet / Wall Mount
Venting Method Ducted (Vertical)
Material Stainless Steel
Warranty 2-Year Limited (Parts and Labor)
Maintenance Clean grease filters monthly with warm water/detergent or dishwasher; wipe stainless steel with mild soap
Weight (Approx.) 30 lbs

Frequently Asked Questions - HRH3004U Thor

What is the power requirement for the Thor HRH3004U range hood?
The range hood requires a 110-120V / 60Hz electrical supply. It must be plugged directly into a 110-volt wall outlet.
How do I clean the grease filters?
Remove the filters by pulling the metal latch down, tilting, and removing. Clean them monthly with warm water and mild detergent, or in a dishwasher using non-phosphate detergent. Let dry before reinstalling.
Can I use the range hood with a non-ducted recirculation setup?
The hood is designed for vertical ducted venting only (7" round duct). For non-ducted use, a recirculation kit would be needed, but this model does not include one. Always use metal ductwork.
How do I operate the fan speeds?
Press the A1 button to turn on. Then use A5 (Low speed) and A6 (High speed) to cycle through speeds: F1 (quiet), F2 (low), F3 (medium), F4 (high).
What does the time delay function do?
Press the A4 button to activate time delay. It keeps the fan running for up to 15 minutes after turning off the stove, then automatically shuts off. You can set the delay time using A5/A6 buttons.
How do I reset the remote control?
The remote sensor (A0) receives IR signals. If the remote is not working, replace the battery (CR2032) and ensure no obstructions between the remote and the hood's sensor.
What type of light bulbs does the hood use?
It uses 2 LED bulbs rated 12V / 1.5W. Do not touch hot bulbs; allow the hood to cool before replacing.
How do I install the range hood?
Installation must follow local codes. Use the included template to mark the center line and bracket positions. Secure the mounting bracket to wall studs, then hang the hood. Connect to a 7" metal duct leading outside. Hire a qualified electrician for wiring.
What does the warranty cover?
Thorkitchen Corporation provides a 2-year limited warranty covering parts and labor for defects in material or workmanship. It does not cover misuse, improper installation, or commercial use.
What should I do if the hood is not working?
Check if the circuit breaker is on and the hood is plugged in. Ensure the remote or touch controls are not locked. If problems persist, contact Thor customer service at 1-877-288-8099.

User questions about HRH3004U Thor

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual HRH3004U - Thor and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HRH3004U by Thor.

USER MANUAL HRH3004U Thor

HRH

Range Hood Installation Guide and User Manual

Thor HRH3004U - HRH - 1

natural_image Technical line drawing of a mechanical component with a cylindrical top and flange (no text or symbols)

Safety Notice

Approved for residential type untis for residential use only read these instructions and be safe.

Please read these instructions completely before starting.

The installation of the appliance must respect all codes.

Important: Save these instructions so that you can provide the electrical inspector in your area.

Safety Warning: Turn off the circuit in the electrical panel and lock front panel to connect the cord Power requirement: 110V-120V/60HZ

CAUTION: USE THIS PRODUCT FOR GENERAL FAN ONLY. DO NOT USE THIS PRODUCT TO EX HAZARDOUS OR EXPLOSIVE MATERIALS.

WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PEOPLE, OBSER FOLLOWING:

  1. Use this unit only for the purposes intended by the manufacturer. If you have any questions about this product, contact the manufacturer.
  2. Before the machine's maintenance or cleaning, turn off the electrical panel and lock the panel blocking feature to prevent from accidentally activating the power. If it is not possible to lock the access panel, attach a highly visible label to the electrical panel.
  3. Δ qualified person should perform the installation and wiring of the electricity in accordance with

space between the walls, ceilings, attics, crawl spaces or garages.

Waring: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT, Install this hood in accordance with all the requirements mentioned.

WARNING: TO REDUCE THE RISK OF FIRE, GREASE THE RANGE.

  1. Never leave the stove unattended when it is at a high temperature. Boil overs cause smoke and ignite. Heat the oil slowly at a low or medium temperature.
  2. Always operate the hood when you use the stove to high heat or when you Flame.
  3. Clean ventilating fans frequently. Do not let fat accumulate on the filters or propellers.
  4. Use proper pan size. Always use a pot size appropriate to the stove element.
  5. Do not touch on-working or off-soon bulb, to avoid any thorny.

Warning

TO AVOID INJURING SOMEONE IN A GREASE FIRE, FOLLOW THE FOLLOWING:

  1. SMOTHER FLAMES with a lid to the dimensions of the cooking hobs, a cookie sheet or other metal tray, then turn off the gas or power supply of the stove. BE CAREFUL NOT TO BURN YOURSELF. If the flames do not AND CALL THE FIRE DEPARTMENT.
  2. NEVER PICK IP A FLAMMING PAN. You could be hurt.
  3. DO NOT USE WATER, including Dish towels or wet towels-a violent steam explosion of dew may
  4. Use an extinguisher only if:

Electrical requirements and installation requirements

Power Requirements

IMPORTANT

Observe all governing codes and ordinances. The customer is responsible for: Contacting an electrician-installer. Check that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI / NFPA 70 (latest edition *) or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 (the latest edition **) of the CSA, and all codes and ordinances in your area. If codes permit and use a wire to separate the ground, it is path of the wire by an electrician. Do not put the device to land on a gas line. Consult a qualified person if you are not sure that the hood is properly grounded electrically. Do not install a fuse in the neutral circuit or circuit ground.

Location of the electrical installation

- The cable must enter the rear wall at least 20 to 1/4 "above the height of the installation base, and between 7-5/8" and 4-7/8 "from the left side of the middle line.

IMPORTANT

Keep these instructions in order to return them to the electrical inspector. The hood must be plugged directly into a 110 volt wall outlet.

Thor HRH3004U - IMPORTANT - 1

natural_image Diagram of a cylindrical device mounted on a base with a circular component, showing fluid flow direction (no text or symbols)

Examples and positioning possibilities ducts

Follow the letter of the guidelines presented in this manual.

The manufacturer declines any liability with respect to any loss, damage or fire caused by non-observance of the instructions

contained in this manual.

Ventilation methods

The hood is equipped with a vertical transition to remove fumes outside.

Recommended diameter conduit model and wall chimney hood and hood island: vertical round pipe 7" tolerance + or - 1.

Models Chimney hood Wall: HRH3003U, HRH3004U

Thor HRH3004U - Examples and positioning possibilities ducts - 1

natural_image Diagram of a cylindrical object being heated by a coiled tube, mounted on a base with no visible text or symbols.

Thor HRH3004U - Examples and positioning possibilities ducts - 2

Thor HRH3004U - Examples and positioning possibilities ducts - 3

Thor HRH3004U - Examples and positioning possibilities ducts - 4

vertical roof venting Roof cap under cabinet range hood pipe diameter7" horizontal wall venting Side wall cap L9"*W4-1/2"

Do not cut a joist or stud unless it is absolutely necessary to do so. If you need to cut a joist or stud, you must build a support Framework, hardware supplied can secure the hood to most walls and ceilings. However, you should technician to check the strength of materials depending on the type of wall or ceiling. Before cutting, make sure there is enough clearance in the ceiling or wall for the outlet pass. You can determine for yourself how high you install the hood above the stove. Over the hood near the stove, it is more effective to capture cooking odour, grease and

Clearance Training
Min27" Max30" 36" Ceiling Height

Installation

If possible, unplug the stove and move it in order to have better access to the rear wall. Otherwise, place a thick blanket on

the counter and the cooking surface to protect it from damage and dirt. Select a flat surface for a

Then put the debris of the cover and hardware on to the protective cap.

Determine and mark the center line on the wall where you installed the canopy hood.

Determine a comfortable height for the user and mark it on the wall behind the stove top.

Place the template on the center line and the bottom of the hood with adhesive tape.

Place the squares of the flue

The flue must be installed against the back wall and the ceiling.

This bracket will keep the chimney up to the top.

Attach the brackets to the wall:

- Align the center lines drawn on the bracket with the center lines on the wall.

- Identify the two screw holes on the wall.

- Drill pilot holes 5/16 "in the locations shown.

- Place the fastening clips to the wall.

- Tightenwood screws, by hand, in the attachments to allow hooks to expand. Remove the screws.

- Drill guide hole, © 5/16inch.

- Make clamp fix to the wall, screw down the bolts on the wall.

- Attach the bracket to the wall using the screws and / or fasteners.

Necessary Tools
Thor HRH3004U - Installation - 1

12.9" (328) 10-7/8" (276) 1/2" (12) 7) 1/4" (70)

10-7/8"(276)For30"36" 8-13/16"(224)For30"36" #1/4"(66) 4-3/8"(112) #3/8"(810) 1/8"(3) 14-11/16"(373.8) 2-1/8"(54) 15-5/16"(390.8) 29-1/2"(749) 35-1/2"(901)

Thor HRH3004U - Installation - 4

natural_image Technical line drawing of a multi-tiered industrial chimney or duct structure (no text or symbols)

Installation dimension figure of HRH3004U as below:

vertical roof venting Roof cap under cabinet range hood pipe diameter7" horizontal wall venting Side wall cap L9"*W4-1/2" 12-7/8" (327) 10-7/8" (276) 11/16"(17) 1/2"(12) 3"(76) -1/16"(126) 3.7"(94) -1/2"(114) 1.1"(282)

10-7/8" (276)For30'36" 8-13/16" (224)For30'36" 4-3/8" (112) 1/8" (3) 2-3/8" (60) 15" 350.8) 12-9/16" (318.8) ø3/8" (ø10) 29-1/2" (750) 35-1/2" (902) ø6-5/8" (ø180) ø7-3/16" (ø180) 3-13/16" (97) 21-5/8" (550) 10-1/4" (260)

12.94° 0000 0000 13.12° Max 17.9° 19.68° 2.36°

Thor HRH3004U - Installation - 8

natural_image Technical line drawing of a tall cylindrical structure with internal components and dimension annotations (no text or symbols)

Thor HRH3004U - Installation - 9

natural_image Technical line drawing of a mechanical assembly with a circular component and a rectangular base (no text or symbols)

Figure4 Figure5

Thor HRH3004U - Installation - 10

natural_image Simple line drawing of a cylinder on a surface with two labeled planes (no text or symbols)

Thor HRH3004U - Installation - 11

natural_image Technical line drawing of a mechanical component with a cylindrical shaft inserted into a stepped base (no text or symbols)

Thor HRH3004U - Installation - 12

Figure 9 ① ②

1-3/16*(30) 12*(305) 10*(256) 5-3/8*(136) 86-7/8*(175) 1-9/16*(40) 2-2/8*(30) 3-9/16*(200) 2*(250) 22*(560) 47-3/4*(1212) 35-3/4*(308) 35-3/4*(356) 35-3/4*(356)

HRH3001U HRH3002U

3*(75) 3*(75) 12*(304)for30" 18*(456)for36" 30*(760)for48" 3*(75) 3*(75)

9/16"(14) 7-3/32"(180) 5/8"(16) 2-7/32"(56)

Description orders for model HRH3001U HRH3003U HRH3004U

A0 A1 A2 F 1 A3 A4 A5 A6

Automatic activation control function of the sensor:

There are 5pcs sensor buttons, 1pc remote control signal lamp (remote controller included), 2pcs stainless steel grease boxes,

2pcs stainless steel baffle filters and 2pcs led bulbs(12V/1.5W).

A0 button: Remote control signal lamp

A1 button: Power( on/off)

A2 button: LED bulb

A3 button: Display screen

A4 button: Time Delay. A5 button: Low speed

A6 button: High speed

A4 button equip with Max 15 minutes after power off, A1 button( on/off) control to directly started c

Open The Fan

Keep your hood working during the cooking, and keep vantilating.

Press A1 button, then A3 display screen open.

Button 5 and 6 activates high speed (F4) average speed(F3) low speed(F2) quiet speed(F1)

button to increase delay-time, set the figure timers as the time you want, max delay-time is 15 min. If time-setting changes from A6 button to A5 button, during the process, speed changes, but does not

Off immediately

Press A1 button two times, fan turn off immediately.

Bulb control

Press A2 button once, turn on the lights, and again to turn off.

Press A2 button or A4 button, then will not able to turn on LED light.

Warning: In case of any scald, do not touch LED light, unless hood is closed or cooled.

A0 button: same as above.

Remote sensor: A0 is the remote control. Remote sensor to receive infrared (IR) remote control signal.

HRH3002U operating instruction as following:

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

MAINTENANCE

WARNING

Before servicing or cleaning unit, switch power off at service panel and lock in access to prevent it accidentally. If the power panel can not be locked, put a prominent warning device, such as a brig

Grease filters

The grease filters should be cleaned once a month or as needed. To remove grease filter, pull the metal latch down. This will disengage the filter hood. Tilt the filter down, then remove. To clean the filters, use a solution of warm water and detergent. Let them dry, then reinstall. The metal filters are dishwasher-safe. Clean filters made entirely of metal in the dishwasher using a non-phosphate detergent. Using a detergent containing phosphates and local water conditions may cause discoloration of the filters, without affecting their performance. This discoloration is not covered under warranty.

Thor HRH3004U - Grease filters - 1

natural_image Isometric view of a rectangular grid structure with parallel lines and small protrusions (no text or symbols)

Hood Cleaning

Cleaning stainless steel: how to keep his "lustrous appearance" and help prevent corrosion.

What to do:

- Wash surfaces regularly with a cloth or a clean cloth soaked in warm water and mild soap or dish detergent.

- Always clean in the direction of squall lines (direction of the grain).

Always rinses well with clear water (2 or 3 times) after cleaning and dry completely

WARRANTY

THE HOOD VENETO TWO YEAR LIMITED WARRANTY

This product has been manufactured by Thorkitchen Corporation. 1335 Fortune Bay Ct, Hoffman Estates IL 60192.

Thorkitchen Corporation disclaims all express warranties except for the following:

This warranty applies to products purchased and located in the United States. Products purchased or area are excluded.

The warranty does not apply to damage resulting from abuse, accident, natural disaster, loss of electrical power to the product for any reason, alteration, outdoor use, improper installation, and improper operation, repair or service of the product by anyone other than an authorized Thorkitchen Corporation, service agency or representative.

Warranties and Duration

Full warranty for Parts and Labor: 2 year

Implied warranties terminate upon expiration of the limited warranty. Some states do not allow limitations on how long implied warranty lasts, so the above limitation may not apply to your implied warranty.

Thorkitchen Corporation will pay for:

All repair labor and cost of replacement parts found to be defective due to material and workmanship provided by a Thorkitchen Corporation Authorized Service Agency during normal working hours. For a Service Agency nearest you, please call 1-877-2888-099.

Thorkitchen Corporation will not pay for:

This limited warranty does not cover:

  1. Service to instruct you on how to use your range hood to correct house wiring, replace or repair house fuses. Service to correct the installation of your range hood.
  2. Repairs when your range hood is used for other than normal single-family household use or when it is used in a manner

appliances used for commercial applications. Should the appliance be sold by the original purchaser during period, the warranty shall extend to the new owner until the expiration date of the original purchaser's warranty period.

Warranty and Product Registration

Thorkitchen Corporation is not responsible for incidental or consequential damages. Under no circumstances, Thorkitchen's liability exceeds the cost that you paid for the product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you. This specific legal rights, and you may also have other rights that vary from state to state. Whenever you call our customer service at 877-288-8099 (THORKITCHEN RANGE HOOD) for technical information and parts sales in the United service for your appliance, please have your complete model number and serial number ready. The n can be found on the product data plate. Please enter the information requested in the spaces provid

Model No. Serial No.

Date of Purchase____ Purchaser____

Dealer Suburb

Town____ Country____

Note: You must provide proof of purchased or installation date for in-warranty service.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Thor

Model : HRH3004U

Category : Range hood