Eberle UPP 16 - Electrical relay

UPP 16 - Electrical relay Eberle - Free user manual and instructions

Find the device manual for free UPP 16 Eberle in PDF.

📄 4 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Eberle UPP 16 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electromagnetic relay
Dimensions 35 × 36 × 19 mm
Supply Voltage 230 V AC, 50/60 Hz
Max. Load Current 16 A (AC-1), 120 A / 20 ms peak
Contact Configuration 1× NO (normally open)
Category of Use AC-7a
Activation Time Max. 20 ms
Deactivation Time Max. 200 ms
Mechanical Switching Cycles Min. 5 × 10^6
LED Indication Green, on relay activation
Terminals Screw terminals, 2.5 mm², tightening torque 0.5 Nm
Operating Temperature -25 to 40°C
Ingress Protection IP20
Pollution Degree 2
Mounting Flush-mounted wall box, ∅ 63 mm
Safety Standards EN 61095
Protection Class Class II (measures required)
Usage Switching electrical loads in dry, enclosed rooms

Frequently Asked Questions - UPP 16 Eberle

Who can install the UPP 16 relay?
The device may only be installed by an electrically skilled person following the circuit diagram and safety regulations.
What is the maximum load current for the UPP 16?
The maximum load current is 16 A (AC-1) with a peak current of 120 A for up to 20 ms.
What cable cross-section should I use?
Use a cable cross-section of 2.5 mm² for switching currents above 10 A.
Can the UPP 16 be used with a room temperature controller?
Yes, it can be combined with room temperature controllers to switch heating loads up to 16 A.
What does the green LED indicate?
The green LED lights up when the relay is activated.
What are the dimensions of the UPP 16?
The dimensions are 35 × 36 × 19 mm.
How do I wire the UPP 16?
Disconnect the mains power, install in a flush-mounted box, and wire according to the diagram: L (phase), N (neutral), load connection, and L' (control relay).
What is the protection class of the device?
The device is designed for protection class II, but measures must be taken during installation to achieve this.
What is the operating temperature range?
The UPP 16 operates in temperatures from -25°C to 40°C.
Can I dispose of the UPP 16 with household waste?
No, do not dispose of with household waste. Recycle at appropriate electronic waste facilities.

User questions about UPP 16 Eberle

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Electrical relay in PDF format for free! Find your manual UPP 16 - Eberle and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UPP 16 by Eberle.

USER MANUAL UPP 16 Eberle

Important!

The device may only be installed by an electrically skilled person as shown on the circuit diagram on the device and in these instructions. The existing safety regulations must be followed.

The relevant installation measures must be taken to achieve the requirements of protection class II. This independently mountable electromechanical device is used to switch electrical loads in dry and enclosed rooms, with normal environment. This device conforms to EN 61095.

1. Areas of Use

Electromagnetic relay in housing for mounting in a flush-mounted wall box ∅ 63mm.

Can also be used in combination with room temperature controllers to achieve switching currents of up to 16 A for electric heating systems.

2. Electrical connection / mounting

  1. Disconnect mains power supply.
  2. Install in flush-mounted box.
  3. Wiring of UPP 16 according to wiring diagram (see marking on product or these instructions). Use cable cross-section of 2.5 mm^2 for switching currents >10 A.

This product should not be disposed of with household waste. Please recycle the products where facilities for electronic waste exist. Check with your local authorities for recycling advice.

3. Wiring diagram

Abbreviation in wiring diagram

L = outer conductor (phase)

N = neutral conductor

= load connection (in combination w/ temperature controller: heating)

L' = control relay

L N L N N L' N

U: 230 V AC 50/50 Hz OUT: 16 A [AC-1] 250 V AC 120 A / 20 ms N N N L' L L 111

4. Technical data

Article number 0490 90 000 004

Supply voltage 230 V AC, 50/60 Hz

Contact 1× NO

Max. load current

16 A [AC-1]

120 A / 20 ms

Use cable cross-section of

2.5 mm ^4 for switching

currents >10 A

Category of use AC-7a

Activation time max. 20 ms

Deactivation time max. 200 ms

Mech. switching cycles min. 5 × 10^6

LED indication green, on relay activation

Terminals

screw terminals 2.5 mm ^4 ,

tightening torque 0.5 Nm

Operating temperature -25÷40°C

Dimensions 35×36×19 mm

Ingress protection IP 20

Pollution degree 2