Product Type Multiprotocol Ethernet Print Server
Dimensions 92.8 mm x 58 mm x 25.3 mm
Weight Approx. 65 g
Power Supply External AC adapter, 7.5 VDC / 500 mA
Printer Connection IEEE 1284 bidirectional parallel port (36-pin)
Network Connection 10Base-T Ethernet (RJ-45)
Network Protocols TCP/IP, NetBEUI, AppleTalk/EtherTalk, NetWare
Management SNMP, Telnet, Web configuration, PS Admin software
Diagnostic LEDs Pw/Tx, Lk/Rx, LPT (power, link, printer activity)
Operating Temperature 0 to 50 °C
Storage Temperature -25 to 55 °C
Humidity 5% to 95% non-condensing
Emissions FCC Class A, CISPR 22 Class A, VCCI Class 1
Safety UL, CSA, TUV/GS (EN60950)
Software Included PS Admin (Windows-based setup and administration)
Default IP Address 192.168.0.1
Default Subnet Mask 255.255.255.0
Maintenance Keep clean and dry; no user-serviceable parts inside
Spare Parts Power adapter only; contact dealer for other parts
General Information Rev. 01 (June 2001), Made in Taiwan

Frequently Asked Questions - DP-101P+ D-LINK

What is the D-Link DP-101P+?
The D-Link DP-101P+ is a Multiprotocol Ethernet Print Server that connects a printer directly to a 10Base-T network, allowing multiple users to share the printer.
Which printers are compatible with the DP-101P+?
The DP-101P+ supports any printer with a standard IEEE 1284 bidirectional parallel port. It is compatible with most parallel printers.
What network protocols does the DP-101P+ support?
It supports TCP/IP, NetBEUI, and AppleTalk protocols, making it compatible with UNIX, Windows, NetWare, and MacOS networks.
How do I configure the DP-101P+?
Configuration can be done using the included PS Admin software for Windows, via Telnet, or through a web browser using the default IP address 192.168.0.1.
What do the LED indicators mean?
Pw/Tx: steady or flashing green indicates power and network transmission. Lk/Rx: steady or flashing green indicates network link and reception. LPT: steady green when printing data is being transferred.
Can I use the DP-101P+ with a DSL or cable modem?
No, the DP-101P+ is designed for Ethernet local area networks and requires a network connection via an RJ-45 port. It cannot directly connect to a modem.
What is the default IP address of the DP-101P+?
The default IP address is 192.168.0.1 with subnet mask 255.255.255.0. Ensure your PC is on the same subnet to access it.
How do I reset the DP-101P+ to factory defaults?
There is no physical reset button. To reset, you must access the device via Telnet or PS Admin and restore defaults, or reflash the firmware as described in the manual.
Why is the LPT LED flashing a pattern?
During self-test, the LPT LED flashes error patterns. For example, steady long flashes mean firmware reload required, while a continuous on indicates DRAM error. Refer to the manual’s error table.
Is the DP-101P+ still supported?
The DP-101P+ is an older model (2001). D-Link may not provide firmware updates, but the device should still work with current network operating systems if properly configured.

User questions about DP-101P+ D-LINK

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Print Server in PDF format for free! Find your manual DP-101P+ - D-LINK and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DP-101P+ by D-LINK.

USER MANUAL DP-101P+ D-LINK

Rev. 01 (June, 2001)

Made In Taiwan

D-LINK DP-101P+ - 1

RECYCLABLE

TABLE OF CONTENTS

ABOUT THIS GUIDE .... 3

INTRODUCTION 4

SERVICE FEATURES....4

EXTERNAL FEATURES 6

Front End....6

Rear End....7

UNPACKING AND INSTALLATION....9

UNPACKING AND INSPECTING 9

INSTALLING THE DP-101P+....10

POWER-UP AND SELF-TEST 11

LED Test Series....11

Component Test Series....11

Operational Test 12

PRODUCT SPECIFICATIONS....13

PORT PINOUTS....15

ABOUT THIS GUIDE

This manual describes the D-Link DP-101P+ Multiprotocol Ethernet Print Server, including full descriptions of its features, detailed installation procedures, and troubleshooting information.

Your DP-101P+ package includes important software components, and additional user manuals. The software components, and procedures for installation and setup of the software, are covered in the PS Admin User's Guide.

1

INTRODUCTION

The DP-101P+ Print Server is a compact pocket-sized print server which connects your Ethernet network directly to your printer, wherever it is. It manages the flow of print files from your workstations or file servers to its connected printers, delivering print jobs to high-performance printers much faster than a file server or a PC acting as a print server can.

Service Features

DP-101P+ print servers improve network printing services in three ways:

- The DP-101P+ picks up the workload of managing print file traffic to its connected printers. This provides workload relief to your file servers, and allows the file servers' full capacity to be used for file access or other direct services to network users. On peer-to-peer networks, workstations can print directly to the DP-101P+ without increasing the load of another workstation or server.

- The DP-101P+'s IEEE 1284 compliant high-speed bi-directional parallel printer port can transmit to high-speed laser printers much faster than a PC's parallel printer port. A high-speed laser printer can be driven at its full capacity.

Because the DP-101P+ is very portable (pocket-sized) and inexpensive compared to a PC-based print server, and because the DP-101P+ connects to your file servers through the network, the printer can be stationed at the location of maximum convenience to users.

The DP-101P+ offers extraordinary flexibility, operating with all major network operating systems and protocols:

♦ TCP/IP

UNIX lpr/lpd (HP-UX, SunOS, Solaris, SCO, UnixWare, IBM AIX)

Windows NT/2000

NetWare 5.x NDPS LPR remote printing

NetBEUI

Windows NT/2000, Windows 95/98/Me, Windows for Workgroups, Microsoft LAN Manager, IBM LAN Server

AppleTalk

MacOS EtherTalk

Your D-Link DP-101P+ package includes PS Admin, a Windows-based setup and administration program, which makes configuration and management of your D-Link print servers quick and easy in a Windows environment. The DP-101P+ also has a Telnet interface for management communications. If Windows is not available on the station you choose for print server administration, then all configuration and management commands may be issued to the DP-101P+, and all console messages and management report information will be returned, via Telnet.

External Features

This section describes the external features of the DP-101P+ print server.

Front End

The network port, power input socket, and LED indicators are all located at the front.

Led Indicators Network Port DC Power Input DP-101P+ Front End

Network Port

The network port (RJ-45 receptacle) provides for connection to the network through 10Base-T Ethernet cabling.

DC Power Input

The DC power input socket uses a 7.5V power supply.

The power supply included in your DP-101P+ package is correct for the DP-101P+. Substitution of other equipment may void warranty.

LED Indicators

The front of the DP-101P+ includes three LED indicators. See "Power-up and Self-Test," Chapter 2, for LED indications upon starting up the DP-101P+. During operations following a normal startup, the LED indicators provide the following status signals:

♦ Pw/Tx

Steady or flashing green confirms power on.

This indicator blinks (briefly dark) when the DP-101P+ is transmitting to the network.

♦ Lk/Rx

Steady or flashing green confirms that the DP-101P+ has a good connection to the Ethernet network.

This indicator blinks (briefly dark) when the DP-101P+ is receiving from the network.

♦ LPT

This indicator shows steady green while the DP-101P+ is transferring print data through its printer port.

Rear End

The DP-101P+ printer port is located at the rear.

D-LINK DP-101P+ - Rear End - 1

natural_image Technical line drawing of a connector with internal grid structure (no text or symbols)

DP-101P+ Rear End

Printer Port

The printer port, is configurable by commands in the PS Admin program, or by commands issued to the DP-101P+ via Telnet. See the PS Admin User's Guide for configuration procedures.

The print server also supports web configuration permitting users to configure settings through the web browser. DP-101P+ default IP address as follows:

♦ Default IP address - 192.168.0.1
♦ Subnet Mask - 255.255.255.0

Note:-

The PC's IP address must correspond with the print server's IP address in the same segment for the two devices to communicate.

UNPACKING AND INSTALLATION

This chapter explains how to install your DP-101P+ print server and connect it to the network. It also describes the automatic power-on self test.

Unpacking and Inspecting

Carefully remove all items from the package. In addition to this Hardware Guide, be certain that you have:

♦ One DP-101P+ print server
♦ One AC Power adapter suitable for your electric power service
♦ One Installation CD-ROM
♦ One Multi-language Quick Installation Guide

If any item is missing, or if you find any damage or mismatch, promptly contact your dealer for assistance.

Installing the DP-101P+

Follow these steps for a trouble-free start of print-server operations with your DP-101P+. Please take particular notice of the warning in step 4: the network connection should be made before supplying power to the DP-101P+.

  1. Confirm proper operation of the printer to be connected to the DP-101P+.
  2. When you have confirmed proper operation of the printer, switch its power off.
  3. Confirm that your network is operating normally.
  4. Connect the DP-101P+ to the network (through the RJ-45 receptacle on the print server's rear end).

WARNING: Configuration problems may result if the DP-101P+ is powered up without first establishing its network connection. Follow this procedure to avoid complications at the configuration stage.

  1. While the printer is power off, connect the DP-101P+ print server directly to the printer parallel port.
  2. Switch printer power on.
  3. Plug the AC Power adapter's output plug into the DC power input socket on the rear end of the DP-101P+.
  4. Plug the AC Power adapter into an electric service outlet. This will supply power to the DP-101P+. (The DP-101P+ has no power switch.) The DP-101P+'s self-test routines will proceed automatically.

Power-up and Self-Test

Whenever the DP-101P+ is powered up, two kinds of testing procedures follow automatically. The first procedure is just a programmed series of LED flashes, to confirm proper operation of the three LED indicators. The second procedure comprises programmed tests of each of the DP-101P+'s major components. If any fault is found during the component test series, testing is halted and a continuous pattern of LED flashes signals the nature of the fault.

LED Test Series

Immediately upon power-up, all three of the LED indicators will show steady green for several seconds. Then the LPT indicator will flash three times while Pw/Tx and Lk/Rx remain steady. Irregularity of any of the LEDs during this LED test series indicates that there is a problem with the LEDs themselves. Contact your dealer for correction of any LED problems before proceeding.

Component Test Series

The actual component tests immediately follow the LED tests. A normal (no fault) result is signaled by three flashes of the LPT indicator and the start of normal print server operation.

If any error condition is found during the component test series, then the test will halt with the LPT LED continuously signaling the particular error according to the following table.

LPT Flash Pattern Error Type
steady long flashesFirmware Reload Required
continuous on DRAM Error
One long, two short flashes Timer INT Error
One long, three short flashes Flash Protected
One long, four short flashes Flash ID Error
One long, five short flashesFlash Erase / Program Error
One long, six short flashesLAN Controller Error
One long, seven short flashesLAN Memory Error
One long, eight short flashes Parallel Controller Error
One long, nine short flashesLPT Error
steady short flashes EEPROM Error
One long, eleven short flashesLAN I/O Base error

In the event of a Firmware Reload Required error at startup, proceed according to instructions given in the PS Admin User's Guide ("PS Admin Administration" section, under the heading "Upgrading the Print Server's Internal Firmware").

In the event that any of the other listed error conditions is encountered on startup, contact your dealer for correction of the fault.

Operational Test

The PS Admin software includes a Print Test function for confirmation of connections and functions. That operational test can be performed after you have completed installation of the PS Admin software, and the PS Admin procedures for configuring the DP-101P+. See instructions given in the PS Admin User's Guide ("Getting Started Setting up Your Print Server" section, under the heading "Testing your Print Server").

PRODUCT SPECIFICATIONS

Printer Connection

Printer Port: IEEE 1284 standard bidirectional parallel interface with 36-pin connector.

Bidirectional Communication: Hewlett-Packard PJL (Printer Job Language) standard for bidirectional communication.

Network Connection

Network Standards: IEEE 802.3 10Base-T Ethernet.

Network Data Transfer Rate: 10Mbps (megabits per second).

Network Connector: RJ-45 connector for 10Base-T twisted pair connection.

Network Protocols

Ethernet Frame Types: 802.2, 802.3, Ethernet II, SNAP (auto-switching)

Transport Protocols: TCP/IP, NetBEUI, AppleTalk/EtherTalk

TCP/IP Protocols Supported: BOOTP, SNMP, Telnet, TFTP, FTP, lpd, RARP, DHCP

Management and Diagnostics

Standard: SNMP

MIBs: MIB-II (RFC 1213)

Diagnostic LED Indicators: Pw/Tx, Lk/Rx, LPT

Environmental and Physical

Power Supply: External power supply providing 7.5VDC/500mA

Dimensions: 92.8mm · 58mm · 25.3mm

Weight: approx. 65g

Operating Temperature: 0 to 50°C

Storage Temperature: -25 to 55°C

Humidity: 5% to 95% non-condensing

Emissions: FCC Class A, CISPR 22 Class A, VCCI Class 1, AS/NZS 3548:1995 Class A

Safety: UL (UL 1950), CSA (CSA950), TUV/GS (EN60950)

PORT PINOUTS

The following table lists the pinouts of the DP-101P+'s 36-pin parallel port connector (identical to the parallel port connector used on most printers.)

Signal names beginning with n are active-low signals.

Pin #SignalSource
1nStrobeH
2 Data 1♠ Bi-Di
3Data 2Bi-Di♠
4Data 3Bi-Di♠
5Data 4Bi-Di♠
6Data 5Bi-Di♠
7Data 6Bi-Di♠
8Data 7Bi-Di♠
9 Data 8Bi-Di♠
10nAckP
11BusyP
12PErrorP
13SelectP
14nAutoFdH
15Not Defined
16Logic Gnd
17Chassis Gnd
18Peripheral Logic HighP
19 Signal Ground (nStrobe)
20 Signal Ground (Data 1)
21 Signal Ground (Data 2)
22 Signal Ground (Data 3)
23 Signal Ground (Data 4)
24 Signal Ground (Data 5)
25 Signal Ground (Data 6)
26 Signal Ground (Data 7)
27 Signal Ground (Data 8)
28Signal Ground (PError, Select, nAck)
29 Signal Ground (Busy, nFault)
30 Signal Ground (nAutoFd, nSelectIn, nInit)
31nInitH
32nFaultP
33Not Defined
34Not Defined
35Not Defined
36nSelectInH

AUSTRALIA

Unit 16, 390 Eastern Valley Way, Roseville, NSW 2069, Australia

TÉL: 61-2-9417-7100 FAX: 61-2-9417-1077

TOLL FREE: 1800-177-100 (Australia), 0800-900900 (New Zealand)

URL: www.dlink.com.au E-MAIL: support@dlink.com.au, info@dlink.com.au

CANADA

2180 Winston Park Drive, Oakville, Ontario L6H 5W1 Canada

TEL: 1-905-829-5033 FAX: 1-905-829-5095 BBS: 1-965-279-8732 FREE CALL: 1-800-354-6522

URL: www.dlink.ca E-MAIL: techsup@dlink.ca

Isidora Goyenechea #2934 of.702, Las Condes, Santiago, Chile

TEL: 56-2-232-3185 FAX: 56-2-2320923 URL: www.dlink.cl

CHINA

2F., Sigma Building, 49 Zhichun Road, Haidian District, 100080 Beijing, China

TEL: 86-10-88097777 FAX: 86-10-88096789

URL: www.dlink.com.c

DENMARK

Naverland 2, DK-2600 Glostrup, Copenhagen, Denmark

TEL:45-43-969040 FAX:45-43-424347 URL:www.dlink.dk

E-MAIL: info@dlink.dk

EGYPT

7 Assem Ebn Sabet Street, Heliopolis Cairo, Egypt

TEL: 202-2456176 FAX: 202-2456192 URL: www.dlink-me.com

E-MAIL: support@dlink-me.com

FRANCE

Plot No.5, Kurla-Bandra Complex Road

Off Cst Road, Santacruz (E), Bombay - 400 098 India

TEL: 91-22-652-6696 FAX: 91-22-652-8914 URL: www.dlink-india.com

E-MAIL: service@dlink.

india.com

ITALY

Via Nino Bonnet No. 6/

b. 20154 Milano. Italy

TEL: 39-02-2900-0676 FAX: 39-02-2900-1723 URL: www.dlink.it

E-MAIL: info@dlink.it

JAPAN

D-LINK JAPAN

10F, 8-8-15 Nishi-Gotanda, Shinagawa-ku, Tokyo 141 Japan

TEL: 81-3-5434-9678 FAX: 81-3-5434-9868 URL: www.d-link.co.jp

RUSSIA

Michurinski Prospekt 49, 117607 Moscow, Russia

TEL: 7-095-737-3389, 7-095-737-3492 FAX: 7-095-737-3390

SINGAPORE

1 International Business Park, #03-12 The Synergy, Singapore 609917

TEL: 65-774-6233 FAX: 65-774-6322

URL: www.dlink-intl.com E-MAIL: info@dlink.com.sg

S. AFRICA

Unit 2, Parkside 86 Oak Avenue

Highveld Technopark Centurion, Gauteng, Republic of South Africa

TEL: 27(0)126652165 FAX: 27(0)126652186

SWEDEN

URL: www.dlink.se

P.O. Box 15036, S-167 15 Bromma Sweden

TEL: 46-(0)8564-61900 FAX: 46-(0)8564-61901 E-MAIL: info@dlink.se

TAIWAN

U.K.

2F, No. 119 Pao-Chung Road, Hsin-Tien, Taipei, Taiwan, R.O.C.

TEL: 886-2-2910-2626 FAX: 886-2-2910-1515 URL: www.dlinktw.com.tw

4

th Floor, Merit House, Edgware Road, Colindale, London, NW9 5AB, U.K.

TEL: 44-20-8731-5555 FAX: 44-20-8731-5511

URL: www.dlink.co.uk E-MAIL: info@dlink.co.uk

U.S.A.

53 Discovery Drive, Irvine, CA 92618 USA

TEL: 1-949-788-0805 FAX: 1-949-753-7033 INFO LINE: 1-800-326-1688

BBS: 1-949-455-1779. 1-949-455-9616

URL: www.dlink.com E-MAIL: tech@dlink.com, support@dlink.com

LIMITED WARRANTY

D-Link provides this limited warranty for its product only to the person or entity who originally purchased the product from D-Link or its authorized reseller or distributor.

Limited Hardware Warranty: D-Link warrants that the hardware portion of the D-Link products described below (“Hardware”) will be free from material defects in workmanship and materials from the date of original retail purchase of the Hardware, for the period set forth below applicable to the product type (“Warranty Period”) if the Hardware is used and serviced in accordance with applicable documentation; provided that a completed Registration Card is returned to an Authorized D-Link Service Office within ninety (90) days after the date of original retail purchase of the Hardware. If a completed Registration Card is not received by an authorized D-Link Service Office within such ninety (90) period, then the Warranty Period shall be ninety (90) days from the date of purchase.

Product Type Warranty Period
Product (excluding power supplies and fans) One (1) Year
Power Supplies and FansOne (1) Year
Spare parts and spare kitsNinety (90) days

D-Link's sole obligation shall be to repair or replace the defective Hardware at no charge to the original owner. Such repair or replacement will be rendered by D-Link at an Authorized D-Link Service Office. The replacement Hardware need not be new or of an identical make, model or part; D-Link may in its discretion may replace the defective Hardware (or any part thereof) with any reconditioned product that D-Link reasonably determines is substantially equivalent (or superior) in all material respects to the defective Hardware. The Warranty Period shall extend for an additional ninety (90) days after any repaired or replaced Hardware is delivered. If a material defect is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to repair or replace the defective Hardware, the price paid by the original purchaser for the defective Hardware will be refunded by D-Link upon return to D-Link of the defective Hardware. All Hardware (or part thereof) that is replaced by D-Link, or for which the purchase price is refunded, shall become the property of D-Link upon replacement or refund.

Limited Software Warranty: D-Link warrants that the software portion of the product (“Software”) will substantially conform to D-Link’s then current functional specifications for the Software, as set forth in the applicable documentation, from the date of original delivery of the Software for a period of ninety (90) days (“Warranty Period”), if the Software is properly installed on approved hardware and operated as contemplated in its documentation. D-Link further warrants that, during the Warranty Period, the magnetic media on which D-Link delivers the Software will be free of physical defects. D-Link’s sole

obligation shall be to replace the non-conforming Software (or defective media) with software that substantially conforms to D-Link's functional specifications for the Software. Except as otherwise agreed by D-Link in writing, the replacement Software is provided only to the original licensee, and is subject to the terms and conditions of the license granted by D-Link for the Software. The Warranty Period shall extend for an additional ninety (90) days after any replacement Software is delivered. If a material non-conformance is incapable of correction, or if D-Link determines in its sole discretion that it is not practical to replace the non-conforming Software, the price paid by the original licensee for the non-conforming Software will be refunded by D-Link; provided that the non-conforming Software (and all copies thereof) is first returned to D-Link. The license granted respecting any Software for which a refund is given automatically terminates.

What You Must Do For Warranty Service:

Registration Card. The Registration Card provided at the back of this manual must be completed and returned to an Authorized D-Link Service Office for each D-Link product within ninety (90) days after the product is purchased and/or licensed. The addresses/telephone/fax list of the nearest Authorized D-Link Service Office is provided in the back of this manual. FAILURE TO PROPERLY COMPLETE AND TIMELY RETURN THE REGISTRATION CARD MAY AFFECT THE WARRANTY FOR THIS PRODUCT.

Submitting A Claim. Any claim under this limited warranty must be submitted in writing before the end of the Warranty Period to an Authorized D-Link Service Office. The claim must include a written description of the Hardware defect or Software nonconformance in sufficient detail to allow D-Link to confirm the same. The original product owner must obtain a Return Material Authorization (RMA) number from the Authorized D-Link Service Office and, if requested, provide written proof of purchase of the product (such as a copy of the dated purchase invoice for the product) before the warranty service is provided. After an RMA number is issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will not be damaged in transit, and the RMA number must be prominently marked on the outside of the package. The packaged product shall be insured and shipped to D-Link, 53 Discovery Drive, Irvine CA 92618, with all shipping costs prepaid. D-Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements, or for which an RMA number is not visible from the outside of the package. The product owner agrees to pay D-Link's reasonable handling and return shipping charges for any product that is not packaged and shipped in accordance with the foregoing requirements, or that is determined by D-Link not to be defective or non-conforming.

What Is Not Covered:

This limited warranty provided by D-Link does not cover:

Products that have been subjected to abuse, accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed;

Initial installation, installation and removal of the product for repair, and shipping costs;

Operational adjustments covered in the operating manual for the product, and normal maintenance;

Damage that occurs in shipment, due to act of God, failures due to power surge, and cosmetic damage; and

Any hardware, software, firmware or other products or services provided by anyone other than D-Link.

Disclaimer of Other Warranties: EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN, THE PRODUCT IS PROVIDED "AS-IS" WITHOUT ANY WARRANTY OF ANY KIND INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A PRODUCT IS SOLD, THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO NINETY (90) DAYS. EXCEPT AS EXPRESSLY COVERED UNDER THE LIMITED WARRANTY PROVIDED HEREIN, THE ENTIRE RISK AS TO THE QUALITY, SELECTION AND PERFORMANCE OF THE PRODUCT IS WITH THE PURCHASER OF THE PRODUCT.

Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF ANY CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF GOODWILL, WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, LOSS OF INFORMATION OR DATA CONTAINED IN, STORED ON, OR INTEGRATED WITH ANY PRODUCT RETURNED TO D-LINK FOR WARRANTY SERVICE) RESULTING FROM THE USE OF THE PRODUCT, RELATING TO WARRANTY SERVICE, OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY, EVEN IF D-LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR, REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON-CONFORMING PRODUCT.

GOVERNING LAW: This Limited Warranty shall be governed by the laws of the state of California.

Some states do not allow exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the foregoing limitations and exclusions may not apply. This limited warranty provides specific legal rights and the product owner may also have other rights which vary from state to state.

Copyright 1999 D-Link Corporation. Contents subject to change without prior notice. D-Link is a registered trademark of D-Link Corporation/D-Link Systems, Inc. All other trademarks belong to their respective proprietors.

No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems Inc., as stipulated by the United States Copyright Act of 1976.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user's guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.

注意

Your name: Mr./Ms

Organization:

Dept.

Your title at organization:

Telephone:

Fax:

Organization's full address:

Country:

Date of purchase (Month/Day/Year):

Product ModelProduct Serial No.* Product installed in type of computer (e.g., Compaq 486)* Product installed in computer serial No.

(* Applies to adapters only)

Product was purchased from:

Reseller's name:

Telephone:

Fax:

Reseller's full address:

Answers to the following questions help us to support your product:

  1. Where and how will the product primarily be used?

Home Office Travel Company Business Home Business Personal Use

  1. How many employees work at installation site?

□1 employee □2-9 □10-49 □50-99 □100-499 □500-999 □1000 or more

  1. What network protocol(s) does your organization use?

☐XNS/IPX ☐TCP/IP ☐DECnet ☐Others

  1. What network operating system(s) does your organization use?

□D-Link LANsmart □Novell NetWare □NetWare Lite □SCO Unix/Xenix □PC NFS □3Com 3+Open

□Banyan Vines □DECnet Pathwork □Windows NT □Windows NTAS □Windows '95

□Others

  1. What network management program does your organization use?

□D-View □HP OpenView/Windows □HP OpenView/Unix □SunNet Manager □Novell NMS

□NetView 6000 □Others

  1. What network medium/media does your organization use?

☐Fiber-optics ☐Thick coax Ethernet ☐Thin coax Ethernet ☐10BASE-T UTP/STP

□100BASE-TX □100BASE-T4 □100VGAnyLAN □Others

  1. What applications are used on your network?

□Desktop publishing □Spreadsheet □Word processing □CAD/CAM

□Database management □Accounting □Others

  1. What category best describes your company?

□Aerospace □Engineering □Education □Finance □Hospital □Legal □Insurance/Real Estate □Manufacturing

□Retail/Chainstore/Wholesale □Government □Transportation/Utilities/Communication □VAR

□System house/company □Other

  1. Would you recommend your D-Link product to a friend?

□Yes □No □Don't know yet

  1. Your comments regarding this product?

PLEASE PLACE STAMP HERE TO D-Link®

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : D-LINK

Model : DP-101P+

Category : Print Server