3270G - Measurement Daytronic - Free user manual and instructions
Find the device manual for free 3270G Daytronic in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Digital Panel Meter / Process Indicator |
| Dimensions (W x H x D) | 96 mm x 48 mm x 100 mm (1/8 DIN) |
| Panel Cutout | 92 mm x 45 mm |
| Weight | Approximately 0.2 kg |
| Power Supply | 85 – 265 V AC/DC, 50/60 Hz |
| Display Type | 5-digit LED, 7-segment, red/green |
| Display Range | -19999 to 99999 |
| Input Types | DC voltage, DC current, potentiometer, strain gauge (bridge) |
| Accuracy | ±0.1% of reading + 1 digit |
| Sample Rate | 10 readings per second (default, adjustable) |
| Main Functions | Peak hold, valley hold, tare, scaling, offset, alarm outputs |
| Alarm Outputs | Two relay outputs, programmable high/low setpoints |
| Analog Output | Optional: 0-10 VDC or 4-20 mA |
| Communication | RS-485 Modbus (optional) |
| Front Panel Sealing | IP65 (NEMA 4X) when panel mounted |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 70°C |
| Relative Humidity | 90% non-condensing |
| Cleaning | Wipe front panel with a soft, damp cloth; do not use solvents |
| Safety Standards | CE, UL, RoHS compliant |
| Spare Parts | Replacement input connector, terminal blocks, relays (obtain from Daytronic) |
| Repairability | Module replaceable by qualified technician; firmware update via communication port |
Frequently Asked Questions - 3270G Daytronic
How do I power the Daytronic 3270G?
Connect the power supply to terminals 1 and 2 (AC) or 1 and 3 (DC) as labeled on the rear panel. The meter accepts 85–265 V AC/DC.
What input types are supported?
The 3270G supports DC voltage (0-10V), DC current (4-20 mA), potentiometer (3-wire), and strain gauge (bridge) inputs. Configure via the front panel or software.
How do I scale the display to my sensor?
Enter the programming mode by pressing and holding the MENU key for 3 seconds. Navigate to 'SCAL' (scale) and set the high and low input values along with their corresponding display values.
Can I set alarms on this meter?
Yes, the 3270G has two relay outputs. In the programming menu, go to 'AL1' and 'AL2' to set the setpoint, hysteresis, and direction (high/low).
How do I perform a tare or zero adjustment?
Press and release the TARE key quickly to zero the display. For offset adjustment, enter programming and set the 'OFFS' parameter to the desired offset value.
What is the maximum display range?
The 5-digit LED display can show values from -19999 to 99999. Decimal point position can be set in the programming menu (dP).
How do I connect a 4-20 mA transmitter?
Connect the transmitter + to terminal 7 (current input) and - to terminal 8 (common). Ensure the meter is configured for current input (INP = 4-20).
Can I use the analog output?
If your model includes the analog output option, it provides 0-10V or 4-20 mA proportional to the displayed value. Configure the output type and scale in the 'AOUT' menu.
How do I reset the meter to factory defaults?
While in programming mode, select the 'FACT' option and confirm. Wait for the meter to reboot. All settings will be restored to factory defaults.
What should I do if the display shows 'Err'?
An 'Err' message indicates an input overrange or sensor fault. Check sensor wiring, input type, and scaling. If the error persists, consult the manual or contact Daytronic support.
User questions about 3270G Daytronic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measurement in PDF format for free! Find your manual 3270G - Daytronic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 3270G by Daytronic.