Festo

SME-8-ZS-KL-LED-24 - Door/window sensor Festo - Free user manual and instructions

Find the device manual for free SME-8-ZS-KL-LED-24 Festo in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Festo SME-8-ZS-KL-LED-24 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Door/Window Sensor (Magnetic Contact Sensor)
Brand Festo
Model SME-8-ZS-KL-LED-24
Dimensions (approx.) 30 mm x 20 mm x 10 mm
Weight Approx. 10 g
Supply Voltage 24 V DC
LED Indicator Yes, for status indication (e.g., open/close)
Switching Output NPN or PNP (depending on variant)
Connection Type Cable with connector (e.g., M8 or M12)
Protection Class IP67 (typical for industrial sensors)
Operating Temperature -25°C to +70°C
Main Function Detects open/close status of doors or windows
Installation Surface mount with screws or adhesive
Maintenance Keep clean; check cable integrity periodically
Safety Observe voltage range; disconnect power before installation
Spare Parts Contact Festo for replacement cables or magnets
Repairability Non-repairable; replace unit if faulty
General Information Use with compatible Festo controllers or PLCs

Frequently Asked Questions - SME-8-ZS-KL-LED-24 Festo

How do I install the Festo SME-8-ZS-KL-LED-24 door/window sensor?
Mount the sensor on the door frame and the magnet on the door. Ensure the sensing face aligns within the specified gap (typically up to 10 mm). Use screws or adhesive tape. Connect the cable to the controller.
What does the LED indicator on the sensor mean?
The LED typically lights up when the sensor detects the magnet (closed position) and turns off when the door is open. Some variants may have a different logic; refer to the manual.
What is the supply voltage range for this sensor?
The sensor operates at 24 V DC. Provide a regulated power supply within ±10% to ensure proper function.
Can I use this sensor with a 5V PLC?
No, the SME-8-ZS-KL-LED-24 requires 24 V DC. Use a level shifter or interface module if connecting to a 5V system.
How do I wire the sensor to a Festo controller?
Typically, there are three wires: brown (24V), blue (0V), and black (signal). Connect according to the controller's input specification. Ensure the output type (NPN/PNP) matches.
What is the maximum cable length?
For reliable operation, keep the cable length under 30 meters. Longer runs may require shielded cable or signal boosters.
How can I test if the sensor is working?
Apply 24V power and bring a magnet close to the sensor. The LED should indicate a state change. Measure the voltage on the signal wire: it should switch between 0V and 24V (or vice versa).
What is the IP rating of this sensor?
The sensor has an IP67 protection rating, meaning it is dust-tight and can withstand temporary immersion in water.
Can I replace the magnet separately?
Yes, the magnet is a separate component. If lost, you can order a replacement from Festo (e.g., SME-8-ZS-KL magnet).
How do I troubleshoot an intermittent signal?
Check the alignment between sensor and magnet, ensure a consistent gap. Verify cable connections and inspect for damage. Also check for electromagnetic interference from nearby equipment.

User questions about SME-8-ZS-KL-LED-24 Festo

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Door/window sensor in PDF format for free! Find your manual SME-8-ZS-KL-LED-24 - Festo and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SME-8-ZS-KL-LED-24 by Festo.

USER MANUAL SME-8-ZS-KL-LED-24 Festo

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Festo

Model : SME-8-ZS-KL-LED-24

Category : Door/window sensor