| Product Type | Door/Window Sensor (Magnetic Contact Sensor) |
| Brand | Festo |
| Model | SME-8-ZS-KL-LED-24 |
| Dimensions (approx.) | 30 mm x 20 mm x 10 mm |
| Weight | Approx. 10 g |
| Supply Voltage | 24 V DC |
| LED Indicator | Yes, for status indication (e.g., open/close) |
| Switching Output | NPN or PNP (depending on variant) |
| Connection Type | Cable with connector (e.g., M8 or M12) |
| Protection Class | IP67 (typical for industrial sensors) |
| Operating Temperature | -25°C to +70°C |
| Main Function | Detects open/close status of doors or windows |
| Installation | Surface mount with screws or adhesive |
| Maintenance | Keep clean; check cable integrity periodically |
| Safety | Observe voltage range; disconnect power before installation |
| Spare Parts | Contact Festo for replacement cables or magnets |
| Repairability | Non-repairable; replace unit if faulty |
| General Information | Use with compatible Festo controllers or PLCs |
Frequently Asked Questions - SME-8-ZS-KL-LED-24 Festo
How do I install the Festo SME-8-ZS-KL-LED-24 door/window sensor?
Mount the sensor on the door frame and the magnet on the door. Ensure the sensing face aligns within the specified gap (typically up to 10 mm). Use screws or adhesive tape. Connect the cable to the controller.
What does the LED indicator on the sensor mean?
The LED typically lights up when the sensor detects the magnet (closed position) and turns off when the door is open. Some variants may have a different logic; refer to the manual.
What is the supply voltage range for this sensor?
The sensor operates at 24 V DC. Provide a regulated power supply within ±10% to ensure proper function.
Can I use this sensor with a 5V PLC?
No, the SME-8-ZS-KL-LED-24 requires 24 V DC. Use a level shifter or interface module if connecting to a 5V system.
How do I wire the sensor to a Festo controller?
Typically, there are three wires: brown (24V), blue (0V), and black (signal). Connect according to the controller's input specification. Ensure the output type (NPN/PNP) matches.
What is the maximum cable length?
For reliable operation, keep the cable length under 30 meters. Longer runs may require shielded cable or signal boosters.
How can I test if the sensor is working?
Apply 24V power and bring a magnet close to the sensor. The LED should indicate a state change. Measure the voltage on the signal wire: it should switch between 0V and 24V (or vice versa).
What is the IP rating of this sensor?
The sensor has an IP67 protection rating, meaning it is dust-tight and can withstand temporary immersion in water.
Can I replace the magnet separately?
Yes, the magnet is a separate component. If lost, you can order a replacement from Festo (e.g., SME-8-ZS-KL magnet).
How do I troubleshoot an intermittent signal?
Check the alignment between sensor and magnet, ensure a consistent gap. Verify cable connections and inspect for damage. Also check for electromagnetic interference from nearby equipment.
User questions about SME-8-ZS-KL-LED-24 Festo