Notice ebm-papst 8212 JH4 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Domestic Fan (Built-in device for air conveyance)
Brand ebm-papst
Model 8212 JH4
Airflow Direction Air outlet over struts
Rotational Direction (viewed at rotor) Counterclockwise
Nominal Voltage 12.0 V DC
Current Consumption 3.200 A
Power Consumption 39.0 W
Speed 14,000 rpm
Max Free-Air Flow 220.0 m³/h
Weight 0.210 kg
Protection Class III (Safety Extra-Low Voltage)
Permitted Ambient Temperature (Operation) -20 °C to 70 °C
Permitted Ambient Temperature (Transport/Storage) -40 °C to 80 °C
Pollution Degree 1 (per DIN EN 60664-1)
Screw Size ISO 4762 - M4
Max Torque (wire outlet corner) 50 Ncm
Max Torque (remaining corners) 110 Ncm
Connection Wires Red (+UB), Blue (-GND)
Cleaning Use moist cloth; no acids, caustic solutions, or solvents
Disposal Observe local regulations

Frequently Asked Questions - 8212 JH4 ebm-papst

What type of device is the ebm-papst 8212 JH4?
The 8212 JH4 is a domestic fan designed as a built-in device for conveying air according to its technical data.
What is the supply voltage and current consumption of this fan?
The nominal voltage is 12.0 V DC and the current consumption is 3.200 A.
Can I control the speed by varying the voltage?
Yes, speed control via the supply voltage is permitted only within the stipulated voltage range. PWM control of the supply voltage is not permitted.
What safety precautions should I take when installing this fan?
Ensure the product is securely fixed with guards in place. Only skilled electricians should install it. Disconnect all poles before working and secure against reconnection.
What should I do if the motor does not rotate?
Check for mechanical blocking, mains voltage faults, or connection errors. If the motor is too hot, let it cool. If the winding is interrupted, replace the product (do not repair).
How do I clean the fan?
Clean carefully with a moist cloth without applying pressure to the rotor. Do not use acids, caustic solutions, or solvents.
What is the ambient temperature range for operation?
The permitted ambient temperature for operation is -20 °C to 70 °C. For transport and storage, it is -40 °C to 80 °C.
Can this fan be used in explosive atmospheres?
No, operating the product in an explosive atmosphere is strictly prohibited as it is not designed for such use.
What should I do if the fan becomes unbalanced?
Unbalance may be due to dirt. Clean the impeller. If still unbalanced after cleaning, exchange the product.
How should I dispose of the fan at the end of its life?
Dispose of the product according to local regulations applicable in your country.

User questions about 8212 JH4 ebm-papst

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Ventilateur domestique in PDF format for free! Find your manual 8212 JH4 - ebm-papst and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 8212 JH4 by ebm-papst.

USER MANUAL 8212 JH4 ebm-papst

natural_image Close-up of a black industrial CPU fan with visible blades and mounting holes (no text or symbols)

Product type, manufacturing date (calendar week/year of construction) and if required, conformity mark can be found on the nameplate on the product.

Please provide us with the contents of the nameplate when making enquiries about the product.

Article number: 9692910196

Original operating manual

INDEX

1 SAFETY REGULATIONS AND INFORMATION 1
2 INTENDED USE 3
3 TECHNICAL DATA 3
4 CONNECTION AND COMMISSIONING 3
5 FAULTS, POSSIBLE CAUSES AND REMEDIES 4

1 SAFETY REGULATIONS AND INFORMATION

Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons or malfunctioning.

This operating manual is an integral part of the product.

In the event of resale or change of ownership the operating manual must accompany the product. This operating manual may be copied and provided as information on potential risks and their avoidance.

Hazard classification of warning notices

The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions:

ebm-papst 8212 JH4 - Hazard classification of warning notices - 1

DANGER

This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed. Observe this warning.

WARNING

The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed. Work with extreme care.

CAUTION

The dangerous situation can occur and can result in minor injuries or damage to property if the warning is not observed.

NOTE

A potentially dangerous situation can occur and results in damage to property if not avoided.

Qualification of personnel

Only skilled electricians are permitted to install the product, to carry out the test run and to work at the electrical unit.

Only instructed and authorized skilled personnel are permitted to transport, unpack, operate and service the product.

Basic safety regulations

Safety risks related to the product must be reassessed after installing in the final device.

The operating manual was developed in accordance with European market requirements and may need adapting to the market requirements of the country in question.

When working at the product, observe the following:

Do not make any changes to the product.

ebm-papst 8212 JH4 - Basic safety regulations - 1

WARNING

Impermissible high load

Stop the product immediately after impermissible loading (e.g. impact, heat, overvoltage).

Electrical voltage and current

ebm-papst 8212 JH4 - Electrical voltage and current - 1
DANGER
Electrical voltage

Regularly check the electrical equipment of the product.

Eliminate immediately loose connections and defective cables.

Safety and protective functions

ebm-papst 8212 JH4 - Safety and protective functions - 1
DANGER
Missing safety device and faulty protective equipment.

Without protective equipment severe injuries can occur, e.g. by taking hold of the rotating equipment.

Operate the product with protection guards only.

Electromagnetic radiation

Electromagnetic compatibility (EMC) may affect the system integration of the product due to interaction.

Ensure the electromagnetic compatibility of the entire system.

Moving parts

ebm-papst 8212 JH4 - Moving parts - 1
DANGER
Self-starting product

If voltage is applied, the motor automatically restarts after a mains failure or when blocking has been eliminated.

Do not stand in the danger zone of the product.

Switch off the mains voltage when working on the product and secure against switching on again.

ebm-papst 8212 JH4 - Moving parts - 2
DANGER
Rotating impeller

Contact with the impeller may result in injuries.

Before starting the product, ensure that it is securely fixed and that the guards are in place.

ebm-papst 8212 JH4 - Moving parts - 3
DANGER
Blocking of escape routes

The product can create dangerously high pressure.

When operating the product ensure that there is adequate supply and exhaust air.

ebm-papst 8212 JH4 - Moving parts - 4
WARNING
Parts transported by the airflow

The product can transport small parts in the airflow and catapult them out.

Ensure that there are no loose small-parts in the intake and exhaust area.

Do not stand in the danger zone of the product.

Long hair, loose-fitting garments and jewellery can be caught and pulled into the product. Risk of injury.

Do not wear loose-fitting garments or jewellery when working on moving parts.

Protect long hair by wearing a hair net.

ebm-papst 8212 JH4 - Moving parts - 5
CAUTION
High risk of fire spreading

Can cause fire to spread.

Never direct the airflow (intake/exhaust side) at a potential source of fire.

Hot surface

ebm-papst 8212 JH4 - Hot surface - 1
CAUTION
High temperature at motor housing. Risk of burns

Provide adequate protection against accidental contact.

Emission

ebm-papst 8212 JH4 - Emission - 1
DANGER
Acoustic alarms can be overheard.

Alarm signals can be overheard

Take technical protective measures, e.g. optical warnings.

ebm-papst 8212 JH4 - Emission - 2
WARNING
A noise pressure level higher than 70dB(A) is possible depending on the installation and operating conditions.

Risk of deafness due to noise.

Take technical protective measures. Provide operating personnel with protective equipment, e.g. ear protection.

Transport

Only transport the product in its original packaging. Secure during transport.

The vibration values, temperature and climate ranges should not be exceeded during transport.

Storage

Store the product in a dry and clean environment that is well protected. Ensure that the storage temperature is adhered to, see Chapter 3, Technical Data. If the product is not operated for a longer period of time, we recommend running it for approx. 15 minutes annually to move the motor bearings.

Cleaning

ebm-papst 8212 JH4 - Cleaning - 1
NOTE
Product damaged during cleaning

Clean the product carefully with a moist cloth without applying pressure to the rotor. Do not use cleaning agents that contain acids, caustic solutions or solvents.

Disposal

When disposing of the product, observe all requirements and regulations that are relevant in your country.

2 INTENDED USE

The product is designed exclusively as a built-in device for conveying air according to the technical data.

Every use that is not in accordance with the intended purpose, is regarded as misuse of the product.

On-site installations must comply with the mechanical, thermal and service life requirements, see Chapter 3, Technical Data.

Intended use includes:

  • Operating the product with all protective equipment
  • Do not put the product into operation before it has been installed in the customer's application
  • Observation of the operating manual

Use for other than the intended purpose

Using the product for the purposes mentioned below is prohibited and can be dangerous:

  • Conveyance of air that contains abrasive particles.
  • Conveyance of air that has a highly corrosive effect.
  • Conveyance of air that has a high dust load, e.g. vacuuming sawdust.
  • Conveyance of inflammable gases/particles.
  • Contact with materials that can damage the product, e.g. acids, caustic solutions, solvents.
  • Exposure to radiation that can damage product components, e.g. strong UV rays or thermal radiation.

- Operating during external vibration.

- Operating the product close to inflammable materials or components.

- Operating the product in an explosive atmosphere

- Use of the product as a safety component or for performing safety-relevant functions.

- Operating in medical devices with life-sustaining or life-saving function.

- Operating in non-stationary systems, e.g. railway vehicles, aircraft and spacecraft.

- Operating with fully or partially dismantled or manipulated protective equipment.

- Operating the product under conditions other than those mentioned in the technical data.

- Furthermore, all fields of application not mentioned under intended use.

An in situ assessment must be conducted of the heating behavior (appropriate and inappropriate operation), the protection against contact, electrical shocks, impact of foreign objects or water and the usage at altitudes higher than 2000 meters.

Contact ebm-papst if you have specific queries regarding the product.

3 TECHNICAL DATA

Drawing, see annex

Technical description

Airflow direction Air outlet over struts
Rotational direction looking at rotorcounterclockwise
Nominal voltage 12,0 V
Current consumption 3.200 mA
Power consumption 39,0 W
Speed 14.000 1/min
Max. free-air flow 220,0 m3/h
Weight 0,210 kg
Protection class III
Max. torque when mounted across both mounting flangeswire outlet corner: 50 Ncm remaining corners: 110 Ncm
Screw sizeISO 4762 - M4 degreased, without an additional brace and

without washer

The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided.

Pollution degree 1 (according DIN EN 60664-1)

There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.

Ambient conditions

Permitted ambient temperature
Transport and storage Operation
-40 °C ... 80 °C -20 °C ... 70 °C

Vibration and shock load

At stationary operation:

sinus vibration1,0 g; 5 - 500 Hz; 3 x 1 sweep (Resonance search run)
Noise0,5 m2/s3, 10 - 50 Hz; +12 dB/oct f. 5 - 10 Hz; -12 dB/oct f. 50 - 100 Hz; 3 x 30 min
Repetitive shockHalf sine; 5 g, 11 ms; 6 x 100 shocks

Transport and storage:

Noise2,0 m2/s3, 5 - 20 Hz; -3 dB/oct f. 20 - 500 Hz; 3 x 30 min
ThrustsHalf sine; 18 g, 6 ms; 6 x 100 shocks

Do not operate your product in the resonance range.

4 CONNECTION AND COMMISSIONING

Connect mechanical parts

ebm-papst 8212 JH4 - Connect mechanical parts - 1

CAUTION

Risk of cutting/squashing when removing the product from the packaging and during mounting.

Grasp the housing and lift the product carefully out of the packaging. Avoid impact.

Wear safety boots and cut-resistant gloves.

ebm-papst 8212 JH4 - CAUTION - 1

NOTE

Risk of damage to electronic components.

Use ESD protective equipment when mounting.

Connect electrical parts

Connect to the mains after installation.

ebm-papst 8212 JH4 - Connect electrical parts - 1

DANGER

Compliance with the electrical installation regulations

Observe the connection regulations that are valid in your country. (e.g. fusing, GFCI)

ebm-papst 8212 JH4 - DANGER - 1

CAUTION

Electrical voltage

The product is a built-in component and has no switch for disconnecting power.

Only connect the product to current circuits that can be switched off by a switch (all poles disconnected). When working on the product, secure the system/machine in which the product is installed against switching on again.

NOTE

Electromagnetic compatibility (EMC) may affect the system integration of the product due to interaction.

Ensure the electromagnetic compatibility of the entire system.

Voltage control

ebm-papst 8212 JH4 - Voltage control - 1

Speed control via the supply voltage is only permitted within the stipulated supply voltage range. Speed control via PWM of the supply voltage is not permitted.

Requirements:

  • Before connecting the product, ensure that the supply voltage corresponds with the product voltage.
  • Check whether the data on the nameplate corresponds with the interface data.

ebm-papst 8212 JH4 - Requirements: - 1

Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions. Ensure that the electrical interface data is adequately protected (mechanical).

Refer to the nameplate for pin connection.

ebm-papst 8212 JH4 - Requirements: - 2

natural_image Three curved lines with labeled endpoints 1 and 2, no text or symbols present
Colour Operation
Wire 1 red + UB
Wire 2 blue - GND

Check connections

NOTE

DC-fans <=60V are products of Protection Class III and must be operated with safety extra-low voltage.

Connect product

Check the product for visible damage and the operability of protective equipment before switching on.

If damage is visible, do not start the product.

5 FAULTS, POSSIBLE CAUSES AND REMEDIES

Replace your product by a new one, do not repair it.

ebm-papst 8212 JH4 - FAULTS, POSSIBLE CAUSES AND REMEDIES - 1

DANGER

Electrical voltage at motor

Wait five minutes after the voltage (all poles) has been switched off before opening the product.

Fault/ErrorPossible cause Possible remedial action
Motor is not rotatingMechanical blockingSwitch off, de-energize and eliminate mechanical blocking.
Mains voltage faultCheck mains voltage, re-connect voltage supply.
Connection faulty Rectify connection, see pin connection.
Motor is too hot Allow motor to cool / identify cause of fault.
Motor winding interruptedExchange product.
Ambient temperature too highReduce ambient temperature if possible.
Impeller out of trueUnbalance of rotating partsClean product if still unbalanced after cleaning, exchange product.

ebm-papst 8212 JH4 - DANGER - 1

In case of further faults, contact ebmpapst.

Technical safety inspection

What requires checking? How to check?Frequency
Protection against accidental contact/ protective clothingVisual inspectionmin. 1/2 yearly
Check product for damage Visual inspectionmin. 1/2 yearly
Fixation of productVisual inspectionmin. 1/2 yearly
Fixation of wiresVisual inspectionmin. 1/2 yearly
Insulation of wiresVisual inspectionmin. 1/2 yearly
Check impeller for wear/sediments/ corrosionVisual inspectionmin. 1/2 yearly

ebm-papst 8212 JH4 - DANGER - 2

1) dimension for worktop mounting

no axial clearance of ball bearings conditional on a pre-load spring

Wertel® / Anteil:Volume / Volume (mm3)
M7-Purey/PureRend. -Dr./ Orang-ko.2018-Erteer-Kurland / 2018-Erteer-KurlandCD-Bezberg/ CD-Environenntdavlar / Base (c):
EMB20191 D7441EInhalal / Titile:
X-Referenwerte | 20-Referenwerte
Tolerung / Tolerung:Dat ouName
Atpesentra/Servien / Des. Tolerung:Barrt./ Bratt
Gew./ B####Drg.-Dr./ Dring le:
Frag./ B####
ebm paperBiomerung / Type of BiometInhalment (Matt Page)Index / IndexFirmi / Dim:Imerle/Brinla
abm paper, M7, Bezberg, B#### & 50 GB
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ebm-papst

Model : 8212 JH4

Category : Ventilateur domestique