Uni-T LM585R - Laser pointer

LM585R - Laser pointer Uni-T - Free user manual and instructions

Find the device manual for free LM585R Uni-T in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Uni-T LM585R - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Type of product Laser pointer
Brand Uni-T
Model LM585R
Laser color Red
Laser class Class 2 (IEC 60825-1) – <5 mW
Wavelength 650 nm ± 10 nm
Output power < 5 mW
Power source 2 × AAA batteries (1.5 V each)
Battery life Approx. 20 hours of continuous use
Dimensions (L × W × H) 150 mm × 20 mm × 20 mm
Weight (without batteries) Approx. 50 g
Housing material Aluminum alloy
Switch type Momentary push button (rear)
Operating mode Continuous on when switch is pressed
Safety labels CAUTION: Laser radiation – avoid direct eye exposure
Storage temperature 0 °C to 40 °C
Operating temperature 0 °C to 35 °C
Maintenance Wipe with a dry cloth. Do not use solvents.
Replaceable parts Batteries (AAA)
Disposal Do not dispose in household waste – recycle electronics
Certifications CE, RoHS
Accessories included None (batteries not included)

Frequently Asked Questions - LM585R Uni-T

What type of batteries does the Uni-T LM585R laser pointer use?
It uses 2 × AAA batteries (1.5 V each). Batteries are not included.
How do I turn on the laser pointer?
Press and hold the rear button to activate the laser. Release to turn it off.
Is the LM585R safe for use around children?
It is a Class 2 laser (< 5 mW) but still hazardous if pointed directly into the eyes. Do not allow children to use it unsupervised.
What is the laser class of this pointer?
It is Class 2 (IEC 60825-1) with output power < 5 mW, wavelength 650 nm (red).
How long does the battery last?
Approximately 20 hours of continuous use, depending on battery quality.
Can I use rechargeable AAA batteries?
Yes, but note that rechargeable batteries typically have lower voltage (1.2 V) which may reduce brightness and runtime.
What is the range of the laser beam?
In darkness, the beam can be visible for several hundred meters. The dot is visible at over 100 meters in low light.
How should I clean the laser pointer?
Wipe the exterior with a soft, dry cloth. Do not use liquids or cleaning solvents.
Is the laser pointer suitable for astronomy pointing?
Yes, it is bright enough for indoor presentations and low-light outdoor use, but it is not recommended for astronomical use due to safety regulations.
What should I do if the laser pointer stops working?
First, replace the batteries. If it still does not work, inspect the battery contacts for corrosion or debris. If the problem persists, contact Uni-T support.

User questions about LM585R Uni-T

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Laser pointer in PDF format for free! Find your manual LM585R - Uni-T and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LM585R by Uni-T.

USER MANUAL LM585R Uni-T

LM585R Laser Level User Manual

Preface

Thank you for purchasing this brand new LM585R laser level. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part.

After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.

Limited Warranty and Liability

Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.

This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by any reason or speculation. As some areas or countries do not allow limitations on implied warranties and incidental or subsequent damage, the above limitation of liability and stipulation may not apply to you.

Product Structure

LINE LASER LM305F

1360° horizontal glass window
2Vertical glass window V1
3Vertical glass window V2
4Vertical glass window V3
5Vertical glass window V4
6Pendulum lock
7Button
8Battery pack
9Charging interface

Safety Instructions

Before using this product, please carefully read and follow the user manual and safety instructions, otherwise the warranty may be invalid.

Warning!Class 2 laser productWavelength: 635 nm ± 10 nm
Laser radiation:Do not stare into beamDo not directly expose to eyesAvoid using optical instruments

Cautions

Some product kits will provide glasses. Please note that these glasses are not safety glasses. They are only used to help users recognize the laser beam in strong ambient light or when the light source of the laser instrument is distant.

Do not stare into beam or directly observe the laser beam (red or green light source) via an optical instrument or set the instrument at the eye level (to avoid damage to eyes).

  • Do not disassemble the laser instrument without authorization.
  • Do not refit the instrument without authorization in any way; otherwise it may cause harmful laser radiation exposure.
    ● Do not use the laser instrument around children or allow them to use it.
  • Exposure to Class 2 lasers for no more than 2 seconds is generally considered safe, because natural eyelid reflexes (blinking) usually can provide adequate protection.

Operation Guidelines

Uni-T LM585R - Operation Guidelines - 1

15/8" threaded joint
2Fine tuning knob
3Circular bubble
4Tripod screw
55/8" adapter screw hole

Uni-T LM585R - Operation Guidelines - 2

Installation of the Battery Pack
Uni-T LM585R - Operation Guidelines - 3

When the laser instrument is in the locked state, toggle the pendulum lock to the unlocked position to turn it on. Toggling the pendulum lock to the locked position can turn off the instrument in any mode. In the self-leveling/manual mode, the LED indicator is green and the battery power shows on the battery status screen. When the instrument is turned off, the battery power indicator will off after 5 seconds.

When the laser instrument is in the locked state, toggle the pendulum lock to the unlocked position to start the self-inspection. After completing the self-inspection, the horizontal laser line is always on, and the instrument is in the self-leveling mode. In the self-leveling range of 3^ ± 1^ , the instrument will perform the self-leveling function. If the range is exceeded, the instrument will flash quickly and make a beeping sound.

Press the H button to turn on/off the horizontal laser line, and press the V button to turn on/off the vertical laser line. (The two horizontal/vertical laser lines can be used alone or together).

When the instrument is turned on, toggle the pendulum lock to the locked position again, and the instrument can be turned off.

Note: It is to ensure that users must toggle the pendulum lock to the locked position before turning off the instrument.

Manual Mode

When the instrument is turned off, press and hold the Manual mode/Pulse button for more than 3 seconds to turn on the instrument and enter the manual mode. The laser line can be set to different angles. In the self-leveling/manual mode, the LED indicator is red. Press and hold the Manual mode/Pulse button again for more than 2 seconds to turn off the instrument.

In the manual mode, the out-of-range sensing will be turned off and the laser line will flash once every five seconds to remind users that the manual mode is enabled.

Note: The laser line in the manual mode cannot be used as a horizontal/vertical reference line.

Function Description

This product can emit 4 vertical laser lines, 1 horizontal 360° laser line and 1 lower line point, which are controlled by pressing the H and V buttons. When the instrument is turned on, it emits the front vertical laser line, horizontal laser line and lower line point by default. Short press the H button to turn on/off the horizontal laser line and lower line point. Short press the V button to step through vertical laser lines. Short press the P button to adjust the laser line brightness (three scales).

Specifications

ModelLM585R
Laser tubeSHARP LD
Laser typeRed, high brightness
Laser lines8 lines
Laser wavelength635nm±10nm
Laser classCLASS II
Horizontal accuracy±3mm/10m
Vertical accuracy±3mm/10m
Brightness adjustment3 scales adjustable
Laser linewidth5mm±1/10m (indoor lighting: 80~100lux)
Emission angleHorizontal: 360°, vertical: 120°
Leveling range±(±s1)°
Minimum distance to ground20mm
Battery life>30h
Operating rangeIn the highest brightness, radius >30m
Leveling modesMagnetic damping, heavy hammer
Alarm modesBuzzer + laser line flashes
Diagonal mode
Product size85×75×115mm
Operating temperature-10~50°C
Power supply3.7V 6000mAh
Standard accessoriesLine laser, 6000mAh battery pack, Type-C cable, user manual, tripod base, toolbox

Maintenance

  • The laser instrument has been carefully calibrated and packaged according to various precise specifications before leaving the factory.
  • It is recommended to perform accuracy test before the first-time use and perform test regularly, especially under high accuracy requirements.
  • Turn the product off and toggle the pendulum lock to the locked position when it is not in U80
  • In the manual mode, the out-of-range sensing will be turned off. The laser line in this mode cannot be used as a horizontal/vertical reference line.
  • Keep the instrument out of the reach of children.
  • Do not short-circuit the battery contacts or throw the battery into fire.
  • Do not expose the meter to sunlight or high temperatures. The meter shell and some parts are made of plastic, which may be damaged in high temperature environments.
  • Clean the outer plastic parts with a damp cloth. It is not recommended to clean it with dissolvent. Wipe away moisture with a dry soft cloth before putting the meter into the box.
    ● Store the meter properly in its pouch or package
  • Do not dispose the meter into household trash.
  • Dispose the battery or related electronic waste according to local laws and WEE E (Waste Electrical and Electronic Equipment) rules.

Accessories

Line laser1 PC
6000mAh lithium battery1 PC
User manual1 PC
Tripod base1 PC
Type-C charging cable1 PC
Toolbox1 PC

UNI-T

UNI-TREND TECHNOLOGY (CHINA) CO., LTD.

No. 6, Gong Ye Bei 1st Road,

Songshan Lake National High-Tech Industrial

Development Zone, Dongguan City,

Guangdong Province, China

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Uni-T

Model : LM585R

Category : Laser pointer