ERGA04EAV37 - Air-conditioner DAIKIN - Free user manual and instructions
Find the device manual for free ERGA04EAV37 DAIKIN in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Air Conditioner Outdoor Unit |
| Brand | Daikin |
| Model | ERGA04EAV37 |
| Refrigerant | R32 |
| Compressor Type | Inverter (Variable Speed) |
| Cooling Capacity (Nominal) | 3.5 kW (≈ 12000 BTU/h) |
| Heating Capacity (Nominal) | 4.0 kW (≈ 13600 BTU/h) |
| Power Supply | 230 V ~ 50 Hz, Single Phase |
| Dimensions (H × W × D) | 845 × 595 × 330 mm |
| Net Weight | 40 kg |
| Sound Pressure Level (Cooling) | ≤ 46 dB(A) |
| Operating Temperature Range (Cooling) | -10°C to 46°C |
| Operating Temperature Range (Heating) | -15°C to 24°C |
| Energy Efficiency Class (Cooling) | A++ |
| Energy Efficiency Class (Heating) | A+ |
| Seasonal Energy Efficiency Ratio (SEER) | ≥ 6.1 |
| Seasonal Coefficient of Performance (SCOP) | ≥ 4.0 |
| Refrigerant Charge | 1.2 kg |
| Max Piping Length | 30 m |
| Max Height Difference | 20 m |
| Cleaning Filter | Indoor unit: washable every 2 weeks |
| Safety Features | Overload protection, auto restart, refrigerant leak detection |
Frequently Asked Questions - ERGA04EAV37 DAIKIN
How often should I clean the air conditioner filters?
You should clean the filters every 2 weeks under normal usage. Remove the indoor unit front panel, take out the filters, wash with mild detergent, rinse, and dry before reinstalling.
What should I do if the air conditioner displays an error code?
Refer to the error code list in the manual. Common codes like U4 indicate communication fault; A6 indicates fan motor error. Turn off the unit and call a qualified technician.
Can I install the outdoor unit in a closed balcony?
No, the outdoor unit requires adequate ventilation. Minimum clearances: 10 cm left/right, 50 cm front, 30 cm rear, and 100 cm above for proper airflow.
What type of refrigerant does the ERGA04EAV37 use?
It uses R32 refrigerant, which is more environmentally friendly than R410A. It is a mildly flammable refrigerant; installation must be done by certified professionals.
How do I reset the air conditioner after a power outage?
Turn off the unit and unplug it for 5 minutes. Plug it back in, wait 2 minutes, then turn it on using the remote. The unit will resume operation automatically.
What is the maximum length for the refrigerant piping?
The maximum piping length is 30 meters, and the maximum height difference between indoor and outdoor units is 20 meters. Longer pipes require additional refrigerant charge.
Why is my air conditioner not heating properly?
Check if the outdoor temperature is below -15°C, as heating capacity decreases. Also ensure the filter is clean, the thermostat is set higher than room temperature, and the unit is in heat mode.
How do I pair a universal remote with this model?
Use the remote code search function. For Daikin units, try code 122 or 153. Point the remote at the unit and press the power button repeatedly until the unit responds.
Does this air conditioner have a self-cleaning function?
Yes, the unit has a auto-clean mode that dries the indoor heat exchanger after operation to prevent mold growth. Activate it via the remote (refer to manual).
What regular maintenance does the outdoor unit require?
Keep the area around the outdoor unit clear of debris and vegetation. Annually, check coil cleanliness and fan operation. A professional inspection is recommended every 2 years.