220 MasterLINE - Motion detector Busch-Jaeger - Free user manual and instructions
Find the device manual for free 220 MasterLINE Busch-Jaeger in PDF.
| Product Type | Passive Infrared Motion Detector |
| Brand | Busch-Jaeger |
| Model | 220 MasterLINE |
| Power Supply | 230 V AC |
| Detection Principle | Passive infrared (PIR) |
| Minimum Mounting Height | 1.7 m |
| Switch-Off Delay | Adjustable via trim potentiometer (short-time pulse available) |
| Brightness Threshold | Adjustable via trim potentiometer |
| Test Mode | 10-minute test mode (daytime operation, 2 sec switch-off delay) |
| Status LED | Flashes quickly on detection in test mode |
| Maximum Switching Current | Depends on ballast manufacturer specification |
| Dimensions (Approx.) | 120 x 80 x 80 mm |
| Weight (Approx.) | 150 g |
| Protection Class | IP44 (typical for outdoor use) |
| Operating Temperature | -20°C to +40°C |
| Safety Notes | Installation by authorized electricians only; disconnect power before handling |
| Care and Cleaning | Clean lens with a soft, dry cloth; do not press on lens |
| Spare Parts / Repairability | Contact manufacturer or authorized service center |
Frequently Asked Questions - 220 MasterLINE Busch-Jaeger
User questions about 220 MasterLINE Busch-Jaeger
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Motion detector in PDF format for free! Find your manual 220 MasterLINE - Busch-Jaeger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 220 MasterLINE by Busch-Jaeger.
USER MANUAL 220 MasterLINE Busch-Jaeger
Risk of death and fire due to electrical voltage of 230 V
- work on the 230V supply system may only be performed by authorised electricians; - Disconnect the mains power supply prior to installation and/or disassembly!
- Detailed user information is available via the link in the "Service" chapter or by scanning the QR
codes (device with corresponding software is required)
- Maximum - Switching Current. The ballast manufacturer's specification determines the possible number of ballasts.
- The Busch-Watchdog is a passive infrared movement detector which switches loads through a
time element when sources of heat move within its detection range
The Busch Watchdoglot an intrusion of attack alarm
Electrical connection

With break switch: On: during the set switch-off delay.
With RC-fuse 6899 and relay
Met RC-suppressor 6899 en relais
Montego
Montageorte




Mounting
Installation sites
Die minimale Montagehöhe des Gerätes beträgt 1,7 m. The minimum height for installing the device is 1.7 m. De minimale montagehoogte van het apparaat bedraagt 1,7 m.
Reichweite

Coverage


Caution! Risk of damaging the device!
The lens of the device is sensitive and can easily sustain
- Do not press on the lens when setting the device!
Preparing the installation

- Remove the locking screw (1) (if installed).
- Press in clamps (2 - 5) on the sides of the housing with a suitable tool
Sundals 100%
- Carefully remove the front of the device
Montage voorbereiden
Depending on where the device is installed, the water drain
may have to be opened.
– To do this, pierce the plastic membrane on the bottom of the
device
Waterafvoer
Set selector switch to T/S.
- The device is now in test mode for 10 minutes (daytime operation, switch-off delay 2 sec.). In addition, each detection is indicated by the status LED flashing quickly.
- After this, the device switches back to standard operating mode.
- To carry out an additional activation test, set the selector switch back to position T/S or interrupt the operating voltage supply for more than 15 seconds.
- The device is now in test mode for another 10 minutes. Test mode is exited automatically after 10 minutes or by adjusting the brightness.