Product TypeWired Outdoor Siren / Alarm
BrandABUS
ModelAZSG10011 (compatible with AZSG10000, AZSG10005, AZSG10010)
Dimensions (W x H x D)210 x 277 x 75 mm
Weight1.035 kg
Power Supply10V–15V DC, cable type Z (EN 50131-4)
Backup BatteryNi-MH 7.2V, 330 mAh
Sound Pressure100 dB(A) @ 1 m (adjustable to 85 dB(A) @ 3 m)
Flashing FrequencyDouble flash @ approx. 1 Hz
Maximum Alarm Duration15 minutes (selectable: 3 min, 15 min, or intermittent)
Protection Class (IP)IP43
Operating Temperature-25°C to +60°C
Humidity (max)95%
Housing MaterialPolycarbonate (shock-resistant)
Security LevelGrade 3 (EN 50131-1:2006+A1:2009)
Environmental ClassIV (EN 50131-1)
Main Features100 dB siren, LED flashing light, tamper detection (front/rear), battery monitoring, comfort LEDs, integrated spirit level, hinged lid, selectable off-switch timer, circuit monitoring (EN Grade 3)
Installation HeightAt least 3 m, out of easy reach
MaintenanceCheck tamper contact, inspect for water/insects, clean with dry cloth; test periodically
SafetyCaution: loud alarm may startle; disconnect power before opening; observe local laws; battery handling
Spare Parts and RepairabilityBackup battery replaceable; jumpers configurable for siren duration, polarity, volume; no other user-serviceable parts; contact dealer for warranty
StandardsEN 50131-1, EN 50131-4; EU Directives: R&TTE, EMC, RoHS, WEEE, Low Voltage
Warranty2 years from purchase date (material/manufacturing defects)

Frequently Asked Questions - AZSG10011 ABUS

How do I install the ABUS Wired Outdoor Siren?
Select a wall location at least 3 m high, accessible for wiring. Open the cover, mount using the integrated spirit level, feed cable through the inlet, connect wires to the terminal block, plug in the backup battery, close the housing, and secure the lid. See the manual for detailed steps.
How can I change the siren duration?
Open the inner housing by removing two screws. Use jumper LK7 for 15 minutes, LK8 for 3 minutes (default), or LK6 for intermittent (3 cycles of 50s on/40s off). Close the housing after setting.
What do the comfort LEDs indicate?
In normal operation, both comfort LEDs (No. 13 and 14) are off. If the supply voltage LED (No. 13) flashes once per second, the supply voltage is missing. If the tamper LED (No. 14) flashes, the housing cover is open.
What is the backup battery for?
The built-in Ni-MH 7.2V 330 mAh battery provides backup power if the main supply is interrupted. It is constantly monitored and automatically charged. During initial startup, the battery may show an error until sufficiently charged.
How do I test the siren?
In installer mode (first 5 minutes after power-up), the siren emits a short test sound when configured. For a self-test, apply a positive signal to the TEST terminal from the alarm panel. You can also manually open the tamper switch to trigger the alarm.
What security grade does this siren meet?
This siren meets Grade 3 according to EN 50131-1:2006+A1:2009, suitable for high-risk residential and commercial applications.
How do I set the polarity of the trigger signals?
Use jumpers LK2 (tamper), LK3 (siren trigger), and LK4 (strobe trigger) to select -ve (default, 0V) or +ve (12V) polarity. The overall mode is set via LK1 for SAB (default, powered from alarm panel) or SCB (powered from internal battery).
Can I adjust the siren volume?
Yes. Use jumper LK9 to choose between STD (100 dB(A) @ 1 m, default) and SPN (85 dB(A) @ 3 m).
What maintenance does the siren require?
Periodically check the tamper contact, inspect for water ingress or insects, clean the housing with a dry cloth. Test the system after maintenance. Always be prepared for a loud alarm when opening the cover.
What does the red battery level indicator (No. 4) mean?
If the red battery level indicator is off, the battery may be faulty, damaged, or deeply discharged. Allow time for charging; if still off, check and replace the battery.

User questions about AZSG10011 ABUS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Alarm in PDF format for free! Find your manual AZSG10011 - ABUS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AZSG10011 by ABUS.

USER MANUAL AZSG10011 ABUS

natural_image Line drawing of a closed electronic device labeled 'ABUS' (no additional text or symbols)

EN

Installation instructions and user guide

Introduction .... 3

Safety information ....4

Scope of delivery 5

Technical data 5

Features 7

Installation....12

Functions and settings: 15

Maintenance ....17

Diagnosis....18

Warranty....18

Disposal 19

Declaration of conformity 19

Notes 19

Introduction

Information on user manual

Dear Customer,

Thank you for purchasing this product. This device is built with state-of-the-art technology.

These instructions contain important installation and operation information (as at 07/2016). Follow the directions and instructions in this user guide to ensure safe operation. Store this guide in a safe place for future reference. This guide constitutes part of the device. If you pass the device on to third parties, please remember to include this guide.

Intended use

Only use the device for the purpose for which it was built and designed. Any other use is considered unintended.

This product complies with current domestic and European regulations. Conformity has been proven, and all related certifications are available from the manufacturer on request.

To maintain this condition and to ensure safe operation, you as the user must pay attention to this user manual. Please contact our specialist dealers for any questions you may have. Further general information and information on product support can be found at www.abus.com on the general page or for dealers and installers, in the Partner portal.

ABUS AZSG10011 - Intended use - 1

ABUS AZSG10011 - Intended use - 2

Please observe the notes and instructions in this user guide! If you do not follow these instructions, any guarantee claim is invalidated. No liability can be accepted for resulting damage.

No part of the product may be changed or modified in any way.

Please observe the local legal requirements. In some European countries, the use of alarms outdoors is prohibited or the maximum alarm duration is limited. Please consult your local authorities on this.

When connecting the rechargeable battery in the sounder, the acoustic alarm may emit a loud sound. This may startle you. Make sure that you don't lose your balance or drop the sounder.

Limitation of liability

Everything possible has been done to ensure that the content of these instructions is correct. However, neither the author nor ABUS Security-Center GmbH & Co. KG can be held liable for loss or damage caused by incorrect or improper installation and operation or failure to observe the safety instructions and warnings. No liability can be accepted for resulting damage. No part of the product may be changed or modified in any way. If you do not follow these instructions, your warranty claim becomes invalid.

Subject to technical modifications.

© ABUS Security-Center GmbH & Co. KG, 07/2016

Safety information

Explanation of symbols

The following symbols are used in this manual and on the device:

SymbolSignal wordMeaning
ABUS AZSG10011 - Explanation of symbols - 1CautionIndicates a risk of injury or health hazards.
ABUS AZSG10011 - Explanation of symbols - 2CautionIndicates a risk of injury or health hazards caused by electrical voltage.
ABUS AZSG10011 - Explanation of symbols - 3ImportantIndicates possible damage to the device/accessories.
ABUS AZSG10011 - Explanation of symbols - 4NoteIndicates important information.
ABUS AZSG10011 - Explanation of symbols - 5The EU Directive WEEE 2012/19/EC governs the proper recovery, treatment and recycling of used electronic devices. This symbol means that, in the interest of environmental protection, the device must be disposed of separately from household or industrial waste at the end of its lifespan in accordance with applicable local legal guidelines. Used devices can be disposed of at official recycling centres in your country. Obey local regulations when disposing of material. Further details on returns (also for non-EU countries) can be obtained from your local authority. Separate collection and recycling conserve natural resources and ensure that all the provisions for protecting health and the environment are observed when recycling the product.

Packaging

Caution

Keep packaging material and small parts away from children. There is a risk of suffocation.

Remove all packaging material before using the device.

Accumulator warning information

Caution

An accumulator battery provides this device with backup power. To guarantee a long lifespan and avoid fire and injury, please note the following:

ABUS AZSG10011 - Caution - 1

Do not dispose of the battery in household waste. Do not expose the battery to any direct heat source or sunlight and do not store in very high temperatures.

The battery must not be burned.

The battery must not come into contact with water.

The battery must not be dismantled, pierced or otherwise damaged.

The battery contacts must not be short-circuited.

The battery must be kept out of the reach of small children.

Scope of delivery

ABUS Wired Outdoor SirenABUS sticker
Quick-start guideInstallation material

Technical data

Product nameABUS Wired Outdoor Siren
Product descriptionSounder
Item numberAZSG10000 (red), AZSG10005 (orange), AZSG10010 (blue)
ManufacturerABUS Security-Center GmbH & Co. KG
Environmental classIV (EN 50131-1:2006 + A1:2009 Section 7)
Protection class, IP protection classIP43
Operating temperature-25 °C to +60 °C
Humidity, maximummax. 95%
Housing materialPolycarbonate
Dimensions (W x H x D)210 x 277 x 75 mm
Weight1.035 kg
Security levelGrade 3 (EN 50131-1 + A1:2009 Section 6)
Flashing frequencyDouble flash @ approx. 1Hz
Sound pressure100 dB(A) @ 1 m
Maximum duration of the acoustic alarm15 minutes
Power supply typeCable type Z (EN 50131-4)
Power consumption/energy consumptionStandby current including comfort LEDs40 mA
Siren sounding alarm360 mA
Normal voltage10V – 15V DC
Backup batteryNi-MH 7.2 V 330 mAh
Standards for intrusion and panic button devicesEN 50131-1:2006+A1:2009EN 50131-4:2009
EU DirectivesR&TTE: 1999/5/ECEMC: 2004/108/ECRoHS: 2011/65/ECWEEE: 2012/19/ECEuP: 2005/32/ECLow Voltage: 2006/95/ECGeneral Safety: 2001/95/EC
GeneralThis product must be installed by a qualified service engineer.

Features

General

This outdoor sounder is an outdoor combination alarm device with siren and flashing light for use with alarm panels. It serves as an optical and acoustic alarm. The sounder and alarm panel communicate via cableways, so fixed wiring is required between the two units. The ABUS Wired Outdoor Sounder is intended for wall installation.

Main features

  • Simple installation
    • 100 dB(A) sound pressure
  • Comfort LEDs
    • High-performance LED flashing light
  • Integrated spirit level

• Hinged lid for easy installation
- Shock-resistant construction from polycarbonate
• Monitors battery voltage
- Tamper detection for front and rear sides
- Selectable off-switch timer

ABUS AZSG10011 - Main features - 1

When installing, ensure that the sounder is fixed out of easy reach (at least 3 m installation height). In addition, the sounder should be visible and audible from afar. Incorrect or unclean installation work may lead to erroneous interpretation of signals. The consequences of which may include false alarms. The costs incurred by potential dispatches of rescue services, such as the fire service or police, must be borne by the operator of the system.

Device description – Sounder

1Cover and lid fixing screw
2Slot for backup battery
3Mounting holes for wall installation
4Spirit level
5Tamper switch
6Mounting hole for tamper mechanism
7Acoustic alarm
8Inner housing
9Cable inlet

Technical diagram of a device with numbered components, likely for assembly or maintenance instructions.

Figure 1: Overview of the sounder

Device description – inner housing

1LEDs for visual alarm (flashing light)
2Inner housing battery
3Battery plug
4Battery level indicator
5Battery holder
6Opening for wires
7Terminal cover
8Fixing bracket for terminal cover
9Drop protection for terminal cover
10LK1 jumper
11Terminal block
12Inner housing screws
13LED display for supply voltage (comfort LED)
14LED display for tamper switch (comfort LED)

ABUS Security-Center GmbH & Co. KG. Linker Kreuthweg 5 - 8644k Affing (Germany) www.abus.com 12 13 14 1 ABUS Security Tech Germany AZSG10000 | AZSG10005 | AZSG10010 ABUS Draht-Außensirene | ABUS Wired Outdoor Sounder Sirenendauer Siren Timing Leitungsüberwachung Trigger Wire Monitor [ LK9 ] [ LK8 ] [ LK7 ] [ LK6 ] 3 Min 15 Min Intermittent = Standard Default [LK5] OFF ON [LK4]+ve -ve STROBE [LK3]+ve -ve TRIG/SIREN [LK2]+ve -ve TAMPER RTN Polarität/Polarity SCB [ LK1 ] SAB STB TRIG HOLD OFF RTN FAULT FAULT TEST AKku/Battery EN50131-4:2009, Type Z Security Grade 3 Environmental Class IV Read Instructions before changing selections. CE DANGER HIGH VOLTAGE INSIDE COVER EXTREME CAUTION SHOULD BE EXERCISED WHEN POWER IS ON. WAIT 3 MINUTES AFTER STROBE HAS STOPPED BEFORE OPENING COVER Datum/Date 11 10 9 6 5 4 7 8

Figure 2: Overview of the inner housing

Installation

Installing the sounder

Step 1: Select installation location for the sounder

Select an installation location which:

  • is inaccessible to intruders and vandals.
  • is clearly visible, so that it acts as a strong deterrent.
  • can be reached with cabling.

Step 2: Open the sounder's cover

  • Open the cover for the lid-fixing screws on the right side (see Fig. 1).
  • Remove the fixing screws and open the cover.

Step 3: Mount the sounder on the wall

ABUS AZSG10011 - Step 3: Mount the sounder on the wall - 1

A pin serves as an anti-removal wall contact to activate the tamper switch on the inside of the sounder. To fit uneven walls, the length of this pin can be adjusted. To do this, turn the screw, which is in the pin, either in or out.

  • Place the siren on the wall and align it vertically using the integrated spirit level. Mark the three fixing points.
  • Drill the holes in the wall to fit the diameter of the anchor screws. Insert the anchor screws supplied, in the holes.
  • Feed the cable provided in the inner housing through the cable inlet on the reverse side.
  • Insert the screws supplied through the sounder's fixing holes. Turn the screws in the screw anchor. Do not tighten the screws yet.
  • Again, vertically align the sounder using the spirit level. Now tighten the screws.

Step 4: Pre-configuration via jumper

• If you would like to change

  • the siren duration from the default value [3 min.], and/or
  • the circuit monitoring from the default values, and/or
  • you would like to set the volume differently to the default value, then:

  • Slide the inner housing to the left, to release it from the catch.

  • Now open the inner housing by undoing the screws at the top and bottom and set the values using the jumpers [LK2] to [LK9] as required.
  • Close the inner housing again using both screws.
  • Snap the housing back into the mount by sliding it to the right.
  • If you wish to set the mode for the power supply, open the terminal block and set the jumper [LK1] accordingly.

Polarity:

+veActivated by positive signal, 12 V fitting.
-veActivated by negative signal, 0 V fitting.

Description of jumpers:

[LK1]Select from SAB or SCB mode
[LK2]Tamper notification with +ve or -ve polarity
[LK3]Siren activation with +ve or -ve polarity
[LK4]Flashing light activation with +ve or -ve polarity
[LK5]Monitoring the signal for activating the siren and flashing light.Please note the following instructions for this function.
[LK6]Cyclical siren duration
[LK7]Siren duration of 15 minutes
[LK8]Siren duration of three minutes
[LK9]Select siren volume fromSTD = 100 dB(A) @ 1 m orSPN = 85 dB(A) @ 3 m

Step 5: Connecting the cable

  • Strip the cable to sufficient length and remove insulation from the individual wires in order to connect these.
  • Remove the cover over the screw terminal on the inner housing by pressing together the lateral terminals upwards and lifting up the cover.
  • Then connect the individual wires to the respective screw terminal and feed the wires individually outwards through the openings provided in the inner housing.
  • See the label on the cover of the inner housing for how to assign the terminal connectors. Every connector is marked on the sticker.

Description of the terminals:

STBSignal from the alarm panel to activate the flashing light
TRIGSignal from the alarm panel to activate the siren
- HOLD OFFPermanent 0 V fitting from the alarm panel
+ HOLD OFFPermanent 12 V fitting from the alarm panel
RTNTamper notification to the alarm panel
FAULTClosed circuit, which opens in the case of fault (both fault terminals)
FAULTClosed circuit, which opens in the case of fault (both fault terminals)
TEST+ve signal from the alarm panel to activate routine self tests

Step 5: Connecting the battery

- Connect the plug of the already inserted battery (No 3 Fig. 2) to the battery holder (No 5 Fig. 2).

Step 6: Closing the sounder

  • Ensure that the inner housing is sitting firmly in the catch in the middle of the housing.
  • Close the inner housing with the terminal cover (No 7 Fig. 2).
  • Snap shut the sounder lid and screw this in tightly with the cover fixing screw.
  • Finally, affix the screw cover over the cover fixing screw.

Functions and settings:

Functions and settings:

General Operation

Installer Start-up

During the initial start-up, it is possible to plug in the battery without activating the sounder. This means that the sounder can be installed and connected in one process, so that you don't have to go back to it again later when the supply voltage is applied.

ABUS AZSG10011 - Installer Start-up - 1

Note

Please note: this function is only available during the initial start-up, or if the sounder has been completely isolated by disconnecting the power supply and removing the battery.

Installer Mode

As soon as the supply voltage is applied, the device will test itself before switching to installer mode. This installer mode lasts five minutes. During this time, the sounder will emit an acoustic signal for three or 15 seconds (depending on which setting was selected), when it is configured. The visual signalling may also be triggered. This function ensures an initial test of the sounder's connection without excessive noise nuisance. When this test phase has run, the sounder emits a short sound signal.

Battery level indicator

The sounder's battery is constantly monitored, to see if it is able to take over the electricity supply, if the power supply is interrupted. During start-up, the battery status display may show an error for a few minutes until the battery has been sufficiently charged.

Error output

This output indicates a battery error. When an error is detected, the output opens the contact (it is an NC output). When self-test is started, this error output is also opened and remains open pending if there is a fault. If there is no error, the contact closes again. The output also opens the circuit, if the device identifies that a conductor for activation is interrupted (only if circuit monitoring [LK5] is activated).

Test input

A positive signal from the alarm panel triggers the sounder to self test.

Settings

Note: the jumpers [LK2] – [LK9] can only be reached if the inner housing has been opened with two screws (Fig. 2 No 12). [LK1] (Fig. 2 No 10) can be reached by opening the terminal cover.

The terminals can all be reached by opening the terminal cover.

[LK1] SAB/SCB

SAB (default setting): If activated, the whole power supply is applied to operate the sounder from the alarm panel

SCB: If activated, the whole power supply to operate the sounder is fed through the internal battery

[LK2] TAMPER RTN

This jumper allows you to select between a negative -ve (default setting) or a positive +ve notification via the tamper contact.

[LK3] TRIG/SIREN

This jumper allows you to select the type of trigger for the acoustic alarm. -ve (default setting) or +ve.

[LK4] STROBE

This jumper allows you to select the type of trigger for the visual alarm (flashing light). -ve (default setting) or +ve.

[LK5] Circuit monitoring

ABUS AZSG10011 - [LK5] Circuit monitoring - 1

Note

This setting is mandatory for EN Grade 3 installations.

When it is activated, the device monitors the integrity of the connection cables for the acoustic alarm, and the visual alarm by evaluating resistor values. These resistors are applied on the opposing signal, and are needed to trigger the acoustic or visual alarm.

Example: If the sounder is controlled by a negative signal –ve (default setting), the monitoring resistor is connected between the positive supply voltage and the signal wire in the alarm panel. If the signal wire for the acoustic alarm is then interrupted or removed, the error output opens the circuit. If the visual alarm's control is interrupted or removed, the flashing light starts. The error output is not opened in this case.

ABUS AZSG10011 - Note - 1

Note

Attaching the resistors in the device yourself, does not comply with the requirements of EN Grade 3.

Maintenance

[LK6] Intermittent

If selected, the siren sounds for a maximum of three passes.

50 sec. ON, 40 sec. OFF, 50 sec. ON, 40 sec. OFF, 50 sec. ON and then stops. (Times approximate)

[LK7] 15 min.

If selected, the siren sounds for a maximum of 15 minutes.

[LK8] 3 min. (default setting)

If selected, the siren sounds for a maximum of 3 minutes.

[LK9] Sound Output

Allows the choice between 100 dB (A) @ 1 m (default setting) and 85 dB (A) @ 3 m.

Operation of the comfort LEDs

In normal operation, the comfort LEDs are not illuminated when the sounder is connected to the power supply, to visually display that the system is operational.

If the tamper contact is opened and/or the power supply is interrupted, this is indicated by the respective LED (No 13 + 14 Fig. 2) flashing.

Maintenance

Caution

Be prepared, that the alarm will be activated as soon as you open the sounder's cover. Make sure that any loud sounds emitted, do not startle you, causing you to fall off the ladder.

  • Test, during routine maintenance, that the sounder works properly.
  • Check the tamper contact, check for signs of seeping water or insects and clean the device as required.
  • Put the terminal cover back on, close the lid, tighten the cover fixing screws and close the screw's covers.
  • Test the system.

Diagnosis

SymptomCauseRemedial action
LED display for supply voltage (No 13 Fig. 2) flashes once every second.Supply voltage not available.Check supply voltage.
LED display for tamper switch (No 14 Fig. 2) flashes once every second.Housing cover is open.Close housing cover.
Red battery level indicator (No 4 Fig. 2) is not illuminated.Faulty, damaged or deeply discharged battery.Give the battery time to charge.Check the battery's status and replace if necessary.
Neither comfort LED (No 13 + No 14 Fig. 2) is illuminatedNormal operation status.No action necessary.

Warranty

ABUS AZSG10011 - Warranty - 1

ABUS products are designed and manufactured with the greatest care and tested according to the applicable regulations.

The warranty only covers defects caused by material or manufacturing errors at the time of sale. If there are demonstrable material or manufacturing errors, the module will be repaired or replaced at the guarantor's discretion.

In such cases, the warranty ends when the original warranty period of two years expires. All further claims are expressly rejected.

ABUS will not be held liable for defects and damage caused by external influences (e.g. transport, use of force, operating errors), inappropriate use, normal wear and tear or failure to observe the instructions in this manual.

In the event of a warranty claim, the original receipt with the date of purchase and a short written description of the problem must be supplied with the product.

If you discover a defect on your wired outdoor sounder which existed at the time of purchase, contact your dealer directly within the first two years following purchase.

Disposal

ABUS AZSG10011 - Disposal - 1

Dispose of the device in accordance with EU Directive 2012/19/EC – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the municipal authority responsible for disposal. You can get information on collection points for waste equipment from your local authority, from local waste disposal companies or your dealer, for example.

Declaration of conformity

ABUS Security-Center GmbH & Co. KG hereby declares that the device with item number AZSG100XX complies with the essential requirements and other relevant provisions of Directives 2011/65/EC, 2014/30/EC. The declaration of conformity can be obtained from the following address:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ABUS

Model : AZSG10011

Category : Alarm