ABB DY DCF77 - Minuterie numérique

DY DCF77 - Minuterie numérique ABB - Free user manual and instructions

Find the device manual for free DY DCF77 ABB in PDF.

📄 1 pages English EN Download 💬 AI Question
Notice ABB DY DCF77 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about DY DCF77 ABB

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Minuterie numérique in PDF format for free! Find your manual DY DCF77 - ABB and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DY DCF77 by ABB.

USER MANUAL DY DCF77 ABB

natural_image Technical line drawing of a mechanical component with dimension标注 (no text or symbols present)

ABB DY DCF77 - 1
CONNECTION DIAGRAMS

ABB DY DCF77 - 2

text_image 12 V== I/O extension port

ABB DY DCF77 - 3

DEVICE STATUS

- When you power on the led emits two RED flashes as follows:

OFFONOFFONOFF
...1 s1 s1 s...

After the power on sequence the DY DCF77 sends data and time to the I/O extension port (then to the connected devices) every 30 minutes.

• The flashing of the GREEN led indicates the status of the device:

ONOFFREPETITIONS
searching for valid signal500 ms500 mscontinuous
exact time acquired less than 30 minutes100 ms100 ms6 every 5 seconds
exact time acquired less than 48 hours100 ms100 ms3 every 5 seconds

- Sending data to the I/O extension port (and to the connected devices) is signaled by the RED flashing of the led for 3 seconds as follows:

ONOFFONOFF ....
100 ms100 ms100 ms100 ms......

Note: at any time you can force sending data to the I/O extension port by pressing the key (accessible by removing the cover, see figure 2).

1

User Manual DCF MODULE FOR EXTERNAL USE ⚠️Read all the instructions carefully

DY DCF77 is a module that allows you to capture the information of data and time. This information may be shared with ABB devices designed to interface with DY DCF77, so as to ensure a synchronization always perfect.

Code Model Description

2CSM250411R1000

DY DCF77 DCF module for external use

SAFETY WARNINGS

During product installation and operation it is necessary to observe the following instructions:

1) The product must be installed by a qualified person, in strict compliance with the connection diagrams.
2) Do not power the instrument if any part of it is damaged.
3) The product must be installed and activated in compliance with current electric system standards.
4) The electrical system in the building in which the product is to be installed should have an over-current switch and a protection device.
5) Do not use the product for purposes different from the one specified.
6) In case of malfunction do not perform repairs and contact immediately the technical support.
7) The product can be used in environments with category of overvoltage III and pollution degree 2.
8) Before accessing the connection terminals, verify that the leads are not live.
9) After installation, inaccessibility to the connection terminals without appropriate tools must be guaranteed.

TECHNICAL CHARACTERISTICS

• Power supply: 12V DC (-20% ÷ +20%)
• Absorption: 4 mA
• DCF frequency: 77.5 kHz
• Wall or pole installation
- Wiring

– Cable length: 100m

- Flexible cables section: 0.75 ÷ 1.5 ~mm^2

– Sheathed cables maximum diameter: 3 mm

• Protection degree: IP54
• Operating temperature: 0 ÷ +50^
• Storage temperature: -25÷ +70 °C
- Operating humidity: 20 ÷ 90% non condensing
• Key to force sending data to the connected devices
• Red / green / orange led for signaling device status (Figure 1)

5

INSTALLATION

• Installation can be wall or pole (by using the adapter in the package)
- Remove the cover by leveraging the teeth on the sides of the product
- Pass the cables through the cable entry on the bottom side and connect the power and bus cables respecting the wiring diagram
- Tighten the cable gland and replace the cover.

ABB DY DCF77 - INSTALLATION - 1
Led for signaling device status

Key to force sending data to the devices
ABB DY DCF77 - INSTALLATION - 2
Figure 1
Figure 2

REFERENCE STANDARDS

Compliance with Community Directives:

2014/53/EU (RED)

is declared with reference to the following harmonized standards:
• EN 60950-1
• ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 300 330

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ABB

Model : DY DCF77

Category : Minuterie numérique