Eta

Stacy 8778 90000 - Kitchen scale Eta - Free user manual and instructions

Find the device manual for free Stacy 8778 90000 Eta in PDF.

📄 32 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Eta Stacy 8778 90000 - page 12
View the manual : English EN Magyar HU Polski PL Slovenčina SK
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Kitchen Scale
Brand Eta
Model Stacy 8778 90000
Maximum Capacity 5 kg
Accuracy 1 g
Dimensions (W x D x H) 260 x 65 x 25 mm
Weight approx. 0.25 kg
Power Supply 1x 3V CR2032 battery (included)
Units of Measurement g, oz, lb:oz, ml (water), ml (milk)
Functions Tare, MODE selection, auto shut-off (60 sec), overload indication
Display LCD
Special Features Foldable tiltable arms, hanging hook
Care & Cleaning Wipe with soft damp cloth; do not immerse in water
Safety Do not immerse; keep away from children; use on hard flat surface
Spare Parts Battery replacement only
Environmental Dispose of battery and electronic parts properly
Protection Class III

Frequently Asked Questions - Stacy 8778 90000 Eta

How do I replace the battery in the Eta Stacy scale?
Remove the battery compartment cover on the back of the scale. Insert a new 3V CR2032 battery, observing the correct polarity. Replace the cover until it clicks. If an insulation band was present, remove it first.
What does the 'Lo' error message mean?
The 'Lo' message indicates that the battery is low and needs to be replaced.
What does 'EEEE' mean on the display?
'EEEE' indicates that the scale is overloaded. The maximum capacity is 5 kg. Remove the excess weight to avoid damage.
Why does the display show 'unST'?
'unST' means the scale is unstable. Place it on a hard, flat surface and allow it to recalibrate. Avoid using on soft or uneven surfaces.
How do I use the tare function?
Place an empty container on the scale and press the TARE button. The display will reset to '0'. Then add the ingredient to measure only its weight. You can repeat this for multiple ingredients; the tare function works as long as the total weight is above 100 g.
How do I change the unit of measurement?
Press the MODE button to cycle through units: g, oz, lb:oz, ml (water), ml (milk). The selected unit appears on the display. The scale remembers the last used mode.
Can I wash the scale under running water?
No, the scale is not waterproof. Clean it only with a soft damp cloth and dry immediately. Do not immerse in water or use chemical cleaners.
What is the maximum weight the scale can measure?
The maximum weight capacity is 5 kg (11 lb). Exceeding this will show an overload error.
How does the auto shut-off work?
The scale automatically turns off after approximately 60 seconds if the display shows '0' or if the weight reading remains unchanged for that period.
Can I hang the scale for storage?
Yes, the scale has a hanging hook (A6) on the back, allowing you to hang it for convenient storage.

User questions about Stacy 8778 90000 Eta

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Kitchen scale in PDF format for free! Find your manual Stacy 8778 90000 - Eta and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Stacy 8778 90000 by Eta.

USER MANUAL Stacy 8778 90000 Eta

natural_image Close-up of a metallic electronic device with a digital display and 'eta' logo (no readable text or symbols beyond branding)

Eta Stacy 8778 90000 - 1

natural_image Illustration of a dental tool on a tray and a bowl with teeth, showing bidirectional arrow (no text or symbols)

III. PŘÍPRAVA K POUŽITÍ

Eta Stacy 8778 90000 - PŘÍPRAVA K POUŽITÍ - 1

natural_image Illustration showing a dental tool on a scale and a bowl of toothed teeth, with no text or symbols present.

III. PRÍPRAVA NA POUŽITIE

Digital kitchen scale

eta 8778

Stacy

USER MANUAL

Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt and, if possible, the box with the internal packing.

I. SAFETY PRECAUTIONS

Eta Stacy 8778 90000 - SAFETY PRECAUTIONS - 1

- Consider the instructions for use as a part of the appliance and pass them on to any other user of the appliance.

- The product is intended for home use and similar (in shops, offices and similar workplaces, in hotels, motels and other residential environments, in facilities providing accommodation with breakfast). It is not intended for commercial use!

- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

- Do not immerse the appliance into water and wash under running water!

- When the appliance is in operation, prevent pets, plants or insects to get in contact with it.

- If the scale was stored in lower temperatures, let it adjust to the room temperature.

- Use the scale horizontally only on places without danger of turning over, keep the appliance sufficiently far from heat power sources (e.g. oven, stove, fireplace, heat radiators) and strong electro-magnetic field (e.g. microwave oven, radio, mobile phone).

- Do not expose the appliance to direct sunlight, low or high temperatures and high moisture.

- Unstable or soft pad under the appliance may influence accuracy of the appliance negatively.

- Protect the scale against dust, moisture, chemicals and abrupt temperature changes.

- Handle the scale with care not to damage it (do not overload and throw it).

- Do not disassemble the scale and do not take any parts out.

- Do not put any objects on the surface of the scale during storing, they could be damaged.

- If you do not intend to use the scale for a long time, remove battery from them.

- If the battery is leaking, remove it immediately; it can damage the scale.

- Dispose of a discharged battery in a suitable way (see par. VII. ENVIRONMENT).

- Never use the appliance for any other purpose than for that described in these instructions for use!

- Keep battery and scale out of reach of children and incapacitated people. A person, who would swallow the battery, must seek medical help immediately.

- All text in other languages and pictures shown on the packaging, or the product itself, are translated and explained at the end of this language mutation.

- The pictures in instruction manual are only illustrative.

- The manufacturer is neither liable for damage caused by improper use of the appliance (e.g. degradation of foods, damage to the appliance etc.) nor for damage caused by failure to observe the safety precautions by operation of the warranty.

II. DESCRIPTION OF THE APPLIANCE (Fig. 1)

A1 — unit of scale

A2 — display

A3 — plate (tiltable arms)

A4 — TARE button – switching the scale on/off and selecting the weight reset function

A5 — MODE button – change the units mode (g>oz>lb:oz>ml(water)>ml(milk))

A6 — hanging hook

1
A2 A1 A3 A6 A5 A4

Eta Stacy 8778 90000 - DESCRIPTION OF THE APPLIANCE (Fig. 1) - 2

natural_image Diagram showing a dental tool interacting with a bowl of tooth (no text or symbols present)

III. PREPARATION FOR USE

Unpack the scale from packaging. Before the very first use, wipe that part of the appliance that may come in contact with foods.

Installation of battery

Battery: 1x 3V CR2032 (included; if there is an insulation band on the battery, remove it to connect the battery).

To replace battery

Remove the battery compartment cover on the back side of the scale and connect a new 3V battery to the connectors. Please take note to the polarity. The other way round replace the battery cover until it engages, an audible click will be heard. When taking out the battery, it is better to press + contact at first since it allows the battery to get out more easily.

IV. OPERATION INSTRUCTIONS

The scale can measure weight and volume in the following units of measurement:

g weight in grams

oz weight in ounces

lb:oz weight in pounds and ounces

ml (WATER) water volume in millilitres

ml (MILK) milk volume in millilitres

Results of measuring and readings on the display

Data on display Unit Indication
1100 g 1100 grams
1:14.6 lb:oz 1 pound and 14.6 ounces
1500 ml (WATER)1500 milliliters of water
1500 ml (MILK) 1500 milliliters of milk

Change of units of weight and volume

Press the MODE button to choose between weighing and measuring volume of water and milk. The selected mode and units of measurement are shown on the display.

Note

- The scale is always switched on in the mode that was used last time.

- If you remove the battery from the scale and re-insert it again (e.g. when replacing it) and switch the scale on, it will switch on in the "g" mode (weight measurement in grams).

- You can put the container or bowl on the scale even before switching the scale on. If you do so, the scale will automatically switch on with the value 0.

- In case that you put the bowl or container on the scale after it has been switched on, press the TARE button A4 (weight reset). The display will show 0. You can then proceed with the required measuring.

- Auto shut-off occurs if display shows ,0' or shows the same weight reading for 60 sec.

- The results of measuring the volume of milk differ from measuring the volume of water due to their density. Milk has subtly higher density than water (approx. 1,026 x).

Operation

1) First of all, please consider the purpose for which you intend to use the scales. It can be used folded up, or with the tiltable arms slid out (see picture 1). When tilting out the arms, pay attention not to damage the arms (avoid opening the arms with too much strength). Open scales can hold containers with the diameter of up to 20 ~cm .

2) Put the scale on a suitable flat surface and switch it on using the TARE button A4.

3) Put the bowl (if you use one) on the scale before switching it on. Do not put things you want to weight on the plate before you turn the appliance on!

4) After the scale is switched on, first of all it is calibrated. When the display shows 0, the appliance is ready for weighing.

5) Using the MODE button A5, set the required mode / units of measurement.

6) Place the food (thing) onto either folded up, or unfolded arms A3. If you need to weigh liquid or any powdery food (e.g. flour), place it into a bowl or container prepared beforehand and deduct its weight using the TARE function. Then wait until the value on the display becomes stable.

7) The scale can then be switched off by holding the TARE button A4 for a longer time or wait ca. 60 seconds after which the scale switches off automatically.

„TARE“ function

To weigh different loads consecutively without removing loads from the scale. Put first Load on the scale, get weight reading. Press A4 TARE button to reset the LCD reading to „0“ before adding next load. The display will show “TARE” in the upper left corner. Add another item and the display will read the added weight. You can repeat this operation. If all products are taken away from the weighing plate, a negative value will appear on the display.

Note

If the total weight is ≤ 100 g, TARE will not appear on the display. Max. weight capacity remains unchanged.

Attention

Remove the excessive weight product from the scales to avoid damage to the appliance.

Error messages shown on the scale display

  1. Lo — replace the batteries
  2. EEEE — scale overload, the weight exceeds 5 kg
  3. unST — unstable indicator - When the scale switched on is it the unstable state, the LCD will indicate „UNST“. Put the scale on hard flat surface, leave it recalibrated, it will work normal

If symptoms such as flashing of the display or erroneous indications appear, remove the scales away from disturbing sources (e.g. microwave oven) or turn off the source for the term of weighing.

V. STORAGE

When you finish working with the scales, put it into a horizontal position or you can hang it on the hooks A6.

VI. MAINTENANCE

Clean the scale only after it has cooled down! Do not use coarse or aggressive detergents (e.g. sharp things, thinners or other solvents)! Wipe the scale surface with a soft wet rag. Pay attention no water penetrates the appliance. DO NOT immerse the scale in water or use chemical/ abrasive cleaning agents. All parts should be cleaned immediately after contact with fats, spices, vinegar and strongly flavored/colored foods. Avoid contact with acids citrus juices. Never dry plastic mouldings over a heat source (e.g. heater, electric/gas stove). Some food can colour the accessories in some way. However, this does not affect the function of the appliance and it is not a reason for a claim. This colouring usually disappears after some time.

Specialized service is required for overhaul maintenance or maintenance requiring disassembly of the internal components of the appliance! The right for warranty repair expires if the above mentioned instructions are not adhered to.

VII. ENVIRONMENT

Eta Stacy 8778 90000 - ENVIRONMENT - 1

If dimensions permit, all pieces have printed symbols of materials used for production of packing, components and accessories as well as recycling symbols. The symbols on the product or documentation means the electric or electronic parts used in the appliance may not be disposed off together with communal waste. Hand over the electric or electronic part to a waste collection yard for free disposal. Proper disposal of the product will help preserving valuable natural resources and preventing potential negative impacts on environment and human health that would otherwise result from improper waste disposal. For more details, please contact your local authorities or collection yard. Fines may be imposed for improper disposal of this type of waste pursuant to national directives. Remove flat batteries from the appliance and dispose them off in a suitable way using special collection centres. Do not incinerate the batteries!

VIII. TECHNICAL DATA

Maximum weighing capacity (kg) 5

Accuracy (g) 1

Weight (kg) about 0.25

Protection class of the appliance III.

Size of the product (mm) 260 x 65 x 25

The manufacturer reserves the right to change the technical specifications and accessories for the respective models.

HOUSEHOLD USE ONLY.

DO NOT IMMERSE IN WATER.

TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.

Eta Stacy 8778 90000 - TECHNICAL DATA - 1

NOTICE

Eta Stacy 8778 90000 - TECHNICAL DATA - 2

natural_image Illustration showing a dental tool on a scale and a bowl of toothed teeth, with bidirectional arrows indicating equivalence (no text or symbols)

Eta Stacy 8778 90000 - TECHNICAL DATA - 3

natural_image Illustration of a dental tool on a scale and its corresponding bowl, showing alignment between the two devices (no text or symbols present)

III. PRZYGOTOWANIE DO UŻYCIA

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Eta

Model : Stacy 8778 90000

Category : Kitchen scale