Pan-Punch 110 - Uncategorized Panduit - Free user manual and instructions
Find the device manual for free Pan-Punch 110 Panduit in PDF.
| Product Type | 110 Punchdown Termination System |
| Brand | Panduit |
| Model | Pan-Punch 110 |
| Wire Gauge Supported | 22-26 AWG solid or stranded |
| Max Wire Outer Diameter | 0.050 in (1.27 mm) |
| Cable Insulation Type | PVC or Plenum rated |
| Pair Capacity per Base | Up to 300 pairs (expandable) |
| Typical Mounting Height | 43-68 inches from floor |
| Recommended Mounting Surface | 3/4 in plywood or equivalent |
| Compatible Punchdown Tools | PDT110 (single wire), PDT110M (multi-pair) |
| Connecting Block Types | 3-pair, 4-pair, 5-pair |
| Color Code Standard | 25-pair with tip/ring colors (white/blue, etc.) |
| Category 5e Compliance | Yes (pairs must stay twisted within 0.5 in of termination) |
| Labeling System | Snap-in label holder with foldable label |
| Safety Precautions | Install in dry locations only; avoid lightning; disconnect network interface before touching terminals |
| Maintenance Notes | Maintain pair twists; avoid sharp cable bends; do not reuse slots for larger gauges |
| Spare Parts Available | Connecting blocks, label holders, base units |
| Environmental Rating | Not for wet locations |
Frequently Asked Questions - Pan-Punch 110 Panduit
User questions about Pan-Punch 110 Panduit
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Uncategorized in PDF format for free! Find your manual Pan-Punch 110 - Panduit and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Pan-Punch 110 by Panduit.
USER MANUAL Pan-Punch 110 Panduit
CABLE REQUIREMENT: Terminates most 22-26 AWG solid or stranded IWC wire with a 0.050" (1.27mm) max. o.d., either PVC or Plenum rated.
LOCATION
Mounting a system at the right height will make wiring changes and additions cost efficient. The optimum height, from the floor to the top of a 300 pair Pan-Punch base, is 68 inches. If the customer needs don't exceed the wiring capacity of one base of 100 pair, the optimum distance from the floor to the top of the system can be reduced to 43 inches. This height will allow for expansion of 300 pair on top and 300 pair underneath.
INSTALLATION
- Use appropriate mounting hardware to install base on desired surface as shown in Figure 1, 3/4" plywood is recommended. (Tip: Panduit lettering should be upright).
- Route cables through slots in the base as shown in Figures 1a (4-pair installation) or 1b (25-pair installation). The wire strip color markings from left to right are white, red, blue, yellow, and violet.
-
Insert each pair into position in wire strip slots while maintaining the proper color sequence. Cable jacket end should be within 1/2" from where cable pairs are inserted. Cable pairs must remain twisted up to the point of connection for Category 5e installation.
-
Inspect cable pair color placement prior to using a PDT110 single wire punchdown tool or PDT110M multi-pair punchdown tool to seat and cut the pairs to length.
-
Position the connecting block over the wired base.
-
Secure the connecting block in place using the PDT110M multi-pair punchdown tool. It is important to keep the tool perpendicular to the base to ensure a good termination. Use a combination of 3, 4, and 5-pair connecting blocks to completely fill the wire strip, such as:
-
Five 5-pair connecting blocks
- Five 4-pair connecting blocks and one 5-pair connecting block
- Seven 3-pair connecting blocks and one 4-pair connecting block
Figure 2a

Figure 1a (4-pair installation)

Figure 1b (25-pair installation)

Figure 2b

CABLE REQUIREMENT: Terminates most 22-26 AWG solid or stranded IWC wire with a 0.050" (1.27mm) max. o.d., either PVC or Plenum rated.
- Once the connecting blocks have been seated, cross-connect wires can be terminated to the top of the connecting blocks or Pan-Punch 110 patch cords can be installed. If cross-connecting, reference Fig. 3.
- Add cable identification to the label, fold label, and slide it into the label holder. The label and label holder snap into position on the base in-between rows of connecting blocks as shown in Figure 4.
| Pair | Tip Color Ring Color | |
| 1 | White/Blue Blue | |
| 2 | White/Orange Orange | |
| 3 | White/Green | Green |
| 4 | White/Brown | Brown |
| 5 | White/Slate | Slate |
| 6 | Red/Blue | Blue |
| 7 | Red/Orange | Orange |
| 8 | Red/Green Green | |
| 9 | Red/Brown | Brown |
| 10 | Red/Slate | Slate |
| 11 | Black/Blue | Blue |
| 12 | Black/Orange | Orange |
| 13 | Black/Green Green | |
| 14 | Black/Brown | Brown |
| 15 | Black/Slate | Slate |
| 16 | Yellow/Blue | Blue |
| 17 | Yellow/Orange | Orange |
| 18 | Yellow/Green | Green |
| 19 | Yellow/Brown | Brown |
| 20 | Yellow/Slate | Slate |
| 21 | Violet/Blue | Blue |
| 22 | Violet/Orange | Orange |
| 23 | Violet/Green | Green |
| 24 | Violet/Brown | Brown |
| 25 | Violet/Slate | Slate |
Figure 3

Figure 4

Notes:
- Pan-Punch product terminates most 22-26 AWG solid or stranded IWC wire with a 0.050" (1.27mm) max. o.d., either PVC or plenum rated.
- Never install wire into a slot previously used for a larger gauge.
- Be careful to strip back cable jacket only as required for termination.
- Use care to maintain pair twists to within 0.50" (13mm) of the termination strip.
- When stripping cable jacket, be careful not to cut the insulation on the individual wires.
- Avoid sharp bends when routing cable.
As with all Wiring Accessories, the following statements apply:
- Never install communications wiring during a lightning storm.
- Never install communications wiring in wet locations unless the product is specifically designed for use in wet locations.
- Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
- Use caution when installing or modifying communication wiring.