Physa Genoa - Chair

Genoa - Chair Physa - Free user manual and instructions

Find the device manual for free Genoa Physa in PDF.

📄 129 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Physa Genoa - page 19
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Aesthetic treatment bed / Electric hairdressing chair
Model Genoa (PHYSAGENOAWHITE)
Power supply voltage 230 V ~ / 50 Hz
Rated power 50 W
Protection class 1
Dimensions (L x W x H) 1800 x 850 x 685 – 890 mm
Weight 80 kg
Maximum user weight 150 kg
Power cable length 3 m
Remote control cable length 3 m
Backrest angle adjustment 84° (motorized)
Seat angle adjustment 14° (motorized)
Footrest adjustment Two gas springs, 0 – 70 mm (manual)
Height adjustment Motorized (variable height)
Intended use Aesthetic treatments and hairdressing
Care and cleaning Clean with a soft, damp cloth; do not use caustic products or metal objects; do not immerse in water
Safety Disconnect before cleaning; use on a flat, stable surface; respect the maximum load; do not stand on the product; keep away from children
Spare parts and repairability Repairs only by the manufacturer's after-sales service; use original parts
General information Read the complete instruction manual before use; indoor use only; maximum ambient temperature 40°C, maximum relative humidity 85%

Frequently Asked Questions - Genoa Physa

How to turn the Physa Genoa bed on and off?
Use the ON/OFF switch located on the device. Position I to turn on, position O to turn off. Always unplug the device after use.
How to use the remote control to adjust positions?
The steering wheel remote control allows you to adjust the backrest, seat, height, and footrest. Each button corresponds to a movement (up/down). Refer to the diagram in the manual to identify each function.
What is the maximum weight supported by the chair?
The maximum user weight is 150 kg. Do not exceed this limit to avoid damaging the product.
How to adjust the footrest manually?
The footrest is adjusted using two gas springs located underneath. Press the spring to increase the tilt angle (up to 70 mm) and lift it to return to the initial position.
How to clean the chair upholstery?
Use a soft, damp cloth. Never use caustic products, metal objects, or steam cleaners. Do not immerse the device in water.
What to do if the remote control stops responding?
Check that the device is turned on and that the remote control is properly connected (dedicated socket). If the problem persists, contact the manufacturer's after-sales service.
Is there a limited continuous operating time?
Yes, the motors can run continuously for a maximum of 2 minutes, after which a stop of 18 minutes is necessary to avoid overheating.
Can I use the chair outdoors?
No, the device is designed for indoor use only. Avoid very humid rooms and direct sunlight.
How to check that the screws are tight?
Regularly inspect all visible screws. If they are loose, tighten them. Regular lubrication of moving parts is also recommended.
Where can I find spare parts or get my bed repaired?
Repairs must be carried out exclusively by the manufacturer's after-sales service using original parts. Do not attempt to repair yourself.

User questions about Genoa Physa

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Chair in PDF format for free! Find your manual Genoa - Physa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Genoa by Physa.

USER MANUAL Genoa Physa

MODELLE PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM:

0 1 2 3 4 5 6 7

MODELL PHYSA PORDENONE POWDER PINK:

1 2 3 4 5 6 7

MODELL PHYSA RHO WHITE:

ATTENTION: The order in which the technical performance values are listed in the table above corresponds to the order in which the models are listed.

1. General description

These instructions are intended to assist you in safe and reliable use. The product is designed and manufactured strictly according to technical specifications using the latest technology and components and maintaining the highest quality standards.

READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE.

To ensure long and reliable operation of the device, care should be taken to operate and maintain the device correctly in accordance with the instructions. The technical data and specifications contained in these instructions are up-to-date. The manufacturer reserves the right to make changes for the purpose of quality improvement.

Explanation of symbols

Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 1The product meets the requirements of relevant safety standards.
Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 2Read the instructions before use.
Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 3Recyclable product.
Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 4CAUTION! or WARNING! or REMEMBER! describing a given situation (general warning sign).
Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 5CAUTION! Risk of electric shock!
Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 6For indoor use only.

Physa Genoa - READ THE INSTRUCTIONS CAREFULLY AND UNDERSTAND THEM BEFORE USE. - 7

CAUTION! The illustrations in this manual are for illustrative purposes only and may differ in some details from the actual product appearance.

The original version of the instructions is the German version. Other language versions are translations from German.

2. Safe use

Physa Genoa - Safe use - 1

CAUTION! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury or death.

The term "device" or "product" in the warnings and instructions refers to the beauty bed.

2.1. Electrical safety

a) The device plug must fit into the socket. Do not modify the plug in any way. Original plugs and matching sockets reduce the risk of electric shock.

b) Avoid touching earthed items such as tubes, radiators, heaters and refrigerators. There is an increased risk of electric shock if your body is earthed and touches the device exposed to direct rain, wet floor and humid environment. If water penetrates into the device, there is an increased risk of damage to the device and electric shock.

c) Do not touch the device with wet or damp hands.

d) Do not use the cable in a wrong way. Never use it to carry the device or to pull the plug out of the socket. Keep the cable away from heat sources, oil, sharp edges or moving parts. Damaged or tangled cables increase the risk of electric shock.

e) If you cannot avoid using the device in a wet environment, use a residual current device (RCD). Using an RCD reduces the risk of electric shock.

f) Do not use the device if the power cable is damaged or shows clear signs of wear. A damaged power cable should be replaced by a qualified electrician or the manufacturer's service.

g) To avoid electric shock, do not immerse the cable, plug or device itself in water or other liquid. Do not use the device on wet surfaces.

h) CAUTION – DANGER TO LIFE! When cleaning or using the device, never immerse it in water or other liquids.

i) Do not use the device in high humidity rooms or in a direct vicinity to a water tanks.

2.2. Safety in the work area

a) Keep the work area tidy and well lit. Disorder or poor lighting can lead to accidents. Be careful, watch what you are doing and use common sense when working with the device.
b) If in doubt as to whether the device is working properly, contact the manufacturer's service.
c) Repairs to the device may only be carried out by the manufacturer's service. Do not carry out repairs yourself!
d) In the event of fire or fire, use only powder or snow (CO2) extinguishers to extinguish fire in the device where there is voltage.
e) Check the condition of the safety stickers regularly. Replace them if they are illegible.
f) Keep these instructions for future reference. If the device is to be passed on to third parties, the instructions for use must be handed over together with the device.
g) Keep packaging parts and small assembly parts out of the reach of children.
h) Keep the device away from children and animals
i) When using this device together with other devices, the other instructions for use must also be followed.

Physa Genoa - Safety in the work area - 1

Remember! Keep children and other bystanders safe while operating the device.

2.3. Personal safety

a) Do not operate the device if you are tired, ill or under the influence of alcohol, drugs or medication which might impair your ability to operate the device.
b) The device is not intended to be used by persons (including children) with reduced mental, sensory or intellectual functions or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or have been given instructions by them on how to operate the device.
c) The device may only be operated by persons who are physically fit, capable of handling the device and who have been adequately trained, who have read these instructions and have received training in health and safety.
d) Be careful and use common sense when operating the device. A short moment of distraction during operation may lead to serious personal injury.
e) To prevent accidental start-up, make sure the switch is in the OFF position before connecting the device to the power source.
f) The device is not a toy. Children should be supervised to ensure that they do not play with the device.

2.4. Safe use of the device

a) Do not overload the device. Use tools that are suitable for the given application. A correctly selected device ensures better and safer performance of work.
b) Do not use the device if the ON/OFF switch does not function properly (does not switch on and off).
c) The device must be disconnected from the power supply before adjustment, cleaning and maintenance. This preventive measure reduces the risk of accidental activation.
d) Keep unused devices out of the reach of children and anyone not familiar with the device or these instructions. Devices are dangerous in the hands of inexperienced users.
e) Keep the device in good working order.
f) Keep the device out of the reach of children.
g) Repair and maintenance of the device should be carried out by qualified persons using only original spare parts. This will ensure a safe use of the device.
h) To ensure the designed operational integrity of the device, do not remove factory-installed covers or loosen any screws.
i) When transporting and moving the device from the place of storage to the place of use, follow the health and safety regulations for manual transport that apply in the country in which the device is used.
j) Avoid situations where the device stops under heavy load during operation. This can cause overheating of the drive elements and subsequent damage to the device.
k) Clean the device regularly to prevent the permanent accumulation of dirt.
I) The device is not a toy. Cleaning and maintenance must not be performed by children without adult supervision.
m) It is forbidden to tamper with the device in order to change its parameters or construction.
n) Keep the device away from sources of fire and heat, direct sunlight and moisture.
o) Exceeding the maximum permissible user weight may cause damage to the product.
p) Do not sit at the end of the chair. This may cause the product to fall over.
q) The weight must be distributed evenly on the chair to avoid it tipping over.
r) Do not stand on the chair.
s) Check from time to time that the screws have not come loose. Tighten if necessary.
t) Regularly lubricate the moving parts of the device which are used to adjust the position.

u) The device should be set up at least 80 cm from the nearest wall or other obstruction to ensure free movement around the device.
v) Do not use the device to store other objects on it.
w) Do not apply mechanical pressure to the device.
x) Do not obstruct the headrest, footrest or backrest during adjustment.
y) The devices have motors that should run for 2 minutes, after which the device needs an 18 minute break.

Physa Genoa - Safe use of the device - 1

CAUTION!

Although the device has been designed to be safe and has been equipped with adequate safeguards, and despite the use of additional safety measures, there is still a small risk of accident or injury when operating the device. Caution and common sense are advised when using the device.

3. Rules of use

The beauty bed is intended for use during cosmetic treatments. The product has an electrically adjustable position. The product is outside the scope of MDD 93/42/EEC for medical devices.

The user is responsible for any damage caused by improper use.

3.1. Description of the device

PHYSA ROME PISTACHIO / PHYSA ERCOLANO GREY / PHYSA SCAFATI POWDER PINK MODELS:

Anatomical diagram of a dental rehabilitation chair with numbered parts labeled 1 through 7.

PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM MODELS:

0 1 2 3 4 5 6 7

PHYSA PORDENONE POWDER PINK MODEL:

1 2 3 4 5 6 7

  1. Headrest
  2. Backrest
  3. Armrest
  4. Seat
  5. Remote control
  6. Base
  7. Footrest

3.2. Preparation for work

LOCATION OF THE DEVICE

The ambient temperature should not exceed 40° C and the relative humidity should not exceed 85%. Keep the device away from any hot surfaces. Always operate the device on a level, stable, clean, fireproof and dry surface and out of the reach of children and persons with reduced mental, sensory and intellectual abilities. Position the device in such a way that the power supply plug can be reached at any time. Make sure that the device's power supply corresponds to the data on the rating plate!

3.3. Working with the device

3.3.1. Starting the device:

a) Unpack the device, remove the foil. Check that the device is not damaged.
b) Insert the end of the remote control cable into the socket on the device [1].
c) Insert the end of the power cord into the socket on the device [2].
d) Plug the plug of the power cord into an electrical outlet.
e) Use the ON/OFF switch [3] to switch the device on (switch to "I" position).

3 2 1

3.3.2. Description of the remote control functions:

The positions of the device are adjusted using the remote control. Each button is responsible for a different control function.

PHYSA ROME PISTACHIO / PHYSA ERCOLANO GREY / PHYSA RHO WHITE MODELS:

1 2 3 4 5 6

  1. Lifting the backrest
  2. Lowering the backrest
  3. Lifting the seat
  4. Lowering the seat
  5. Lifting the device
  6. Lowering the device

PHYSA RHO WHITE MODEL:

  1. Lifting the footrest
  2. Lowering the footrest

PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA PORDENONE POWDER PINK / PHYSA BATTIPAGLIA WHITE / PHYSA CHIETI CREAM / PHYSA SCAFATI POWDER PINK MODELS:

1 2 3 4 5 6 7 8

  1. Lifting the backrest

  2. Lowering the backrest

  3. Lifting the footrest

  4. Lowering the footrest

  5. Lifting the device

  6. Lowering the device

  7. Lifting the seat

  8. Lowering the seat

PHYSA ROME PISTACHIO / PHYSA ERCOLANO GREY models have a gas spring which is responsible for adjusting the position of the footrest:

  1. Depress the gas spring which is located under the footrest to deepen the angle of the footrest.

Close-up of a white car interior with a cable and connector, highlighting a red square detail (no text or symbols visible)

  1. Lift the spring to return the footrest to its original position.

3.3.3. Ending work with the device:

a) When finished working, switch off the device using the ON/OFF switch.
b) Remove the mains plug from the power socket.

3.4. Cleaning and maintenance

a) Before cleaning and when the device is not in use, pull the power supply plug.
b) Use only non-corrosive agents for cleaning the surface.
c) Store the device in a dry and cool place protected from moisture and direct sunlight.
d) Do not spray the device with a stream of water and do not immerse it in water.
e) Regularly inspect the device for technical failure and damage. If necessary, replace worn parts.
f) Use a soft, damp cloth for cleaning.
g) Do not use sharp and/or metal objects for cleaning (e.g. a wire brush or metal scraper) as these may damage the surface of the device.
h) Do not clean the device with oily substances.

Dane techniczne

MODELE PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM:

0 1 2 3 4 5 6 7

MODEL PHYSA PORDENONE POWDER PINK:

1 2 3 4 5 6 7

MODELES PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM :

0 1 2 3 4 5 6 7

MODÈLE PHYSA PORDENONE POWDER PINK :

1 2 3 4 5 6 7

MODELLI PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM:

0 1 2 3 4 5 6 7

MODELLO PHYSA PORDENONE POWDER PINK:

1 2 3 4 5 6 7

MODELOS PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM:

0 1 2 3 4 5 6 7

MODELO PHYSA PORDENONE POWDER PINK:

1 2 3 4 5 6 7

  1. Reposacabezas
  2. Respaldo
  3. Reposabrazos
  4. Asiento
  5. Mando
  6. Base
  7. Reposapiés

PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM TÍPUSOK:

0 1 2 3 4 5 6 7

PHYSA PORDENONE POWDER PINK TÍPUS:

1 2 3 4 5 6 7

MODELLER PHYSA ACIREALE POWDER PINK / PHYSA ROVIGO BLACK / PHYSA VELLETRI WHITE / PHYSA GENOA WHITE / PHYSA BATTIPAGLIA WHITE / PHYSA RHO WHITE / PHYSA CHIETI CREAM:

0 1 2 3 4 5 6 7

MODEL PHYSA PORDENONE POWDER PINK:

1 2 3 4 5 6 7

For the disposal of the device please consider and act according to the national and local rules and regulations.

CONTACT

expondo Polska sp. z o.o. sp. k.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Physa

Model : Genoa

Category : Chair