USER MANUAL MFH217 IFM
Operating instructions Hydraulic cylinder sensor
MFH M9H
1 Preliminary note
You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com.
1.1 Symbols used
√ Requirement
Instructions
Reaction, result
[...] Designation of keys, buttons or indications
→ Cross-reference

Important note
Non-compliance may result in malfunction or interference.

Information
Supplementary note
2 Intended use
The unit detects ferromagnetic metals (FE metals) without contact and indicates their presence by a switching signal.
3 Mounting
3.1 Installation of devices without end stop (MFH)

1: Sensor
2: Welding bush
The device can be adjusted to the piston rod via the insertion depth.
ATTENTION
During set-up, do not screw in the device too deeply to avoid mechanical damage to the device, piston rod and cylinder.

For mounting with a fixed end stop, use devices from the M9H series.

1: Sensor
2: Piston rod
3: Piston with switching cam
▶ Make sure that the piston rod is in the end position to be detected.
▶ Screw the device up to the end stop.
▶ Unscrew the device half a turn ( 0.5 mm) to avoid mechanical damage.
▶ Tighten the fixing nut (tightening torque → data sheet).
3.2 Installation of devices with end stop (M9H)

1: Sensor
2: Welding bush
▶ Screw the device into the M thread.
▶ Tightening torque → data sheet.
3.3 Installation of devices for plunger detection

▶ Screw the device into the M thread.
▶ Tightening torque → data sheet.
1: Sensor
2: Screw-on block
3: Plunger
4 Electrical connection

The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment must be adhered to.
▶ Disconnect power.
▶ Connect the unit as specified in the data sheet / type label.
5 Maintenance, repair and disposal
The operation of the unit is maintenance-free.
Only the manufacturer is allowed to repair the unit.
▶ After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations.