AR24TXFCAWKNEU - Air conditioner SAMSUNG - Free user manual and instructions
Find the device manual for free AR24TXFCAWKNEU SAMSUNG in PDF.
| Brand | Samsung |
| Model | AR24TXFCAWKNEU |
| Category | Split air conditioner |
| Product type | Wall-mounted split system (indoor unit + outdoor unit) |
| Indoor unit dimensions (W x H x D) | 1050 x 298 x 236 mm |
| Outdoor unit dimensions (W x H x D) | 880 x 638 x 310 mm |
| Indoor unit weight | 13.5 kg |
| Outdoor unit weight | 40 kg |
| Power supply | 220-240 V ~ 50 Hz, single-phase |
| Cooling capacity | 7.0 kW (24,000 BTU/h) |
| Heating capacity | 7.5 kW (heat pump) |
| Refrigerant | R32 |
| Global Warming Potential (GWP) | 675 |
| Main functions | Cooling, heating, dehumidification, ventilation, night mode, timer, self-cleaning |
| Filter | Washable air filter (recommended every 2 weeks) |
| Remote control | Yes, included |
| Noise level (indoor unit) | Up to 45 dB(A) |
| Noise level (outdoor unit) | Up to 55 dB(A) |
| Maintenance and cleaning | Clean filters regularly, do not interfere with the refrigeration circuit |
| Safety | Overload protection, fault self-diagnosis |
| Spare parts and repairability | Filters, remote control, batteries; repair by a certified professional |
| General information | User manual available in French and English (24 pages) |
Frequently Asked Questions - AR24TXFCAWKNEU SAMSUNG
User questions about AR24TXFCAWKNEU SAMSUNG
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air conditioner in PDF format for free! Find your manual AR24TXFCAWKNEU - SAMSUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AR24TXFCAWKNEU by SAMSUNG.
USER MANUAL AR24TXFCAWKNEU SAMSUNG
COMMISSION DELEGATED REGULATION (EU) No 626/2011 ^i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ^ii)
| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | |
| B Model name (Indoor/Outdoor) - | AR18TXEAAWKN/AR18TXEAAWKX | AR18TXFCAWKN/AR18TXFCAWKX | AR24TXFCAWKN/AR24TXFCAWKX | |
| C Sound Power Level (Inside/Outside) dB(A) 58/65 58/65 62/68 | ||||
| D Refrigerant name ^1) | -R-32 | R-32 R-32 | ||
| E GWP - 675 675 675 | ||||
| F | SEER | 6,8 | 6,8 | 6,4 |
| G | Energy efficiency class (SEER) | -A++ | A++ | A++ |
| H | Q_CE^2) (cooling season) | kWh/ a^II) | 257 | 257 |
| I | Pdesignc | kW | 5,0 | 5,0 |
| J | SCOP(Average) | - | 4,1 | 3,8 |
| K | Energy efficiency class SCOP(Average) | - | A+ | A |
| L | Q_HE^3) heating season (Average) | kWh/ a^II) | 1298 | 1400 |
| M | Pdesignh (Average) | kW | 3,8 | 3,8 |
| N | Back up heating capacity (Average) | kW | - | - |
| O | Declared capacity(Average) | kW | 3,8 | 3,8 |
| P | Other heating seasons suitable for use | - | Warmer | Warmer |
| Q | SCOP(Warmer) | 4,8 | 4,8 | 4,6 |
| R | Energy efficiency class SCOP(Warmer) | -A++ | A++ | A++ |
| S Q | ^3)_HE heating season (Warmer) | kWh/ a^II) | 642 613 670 | |
| T | Pdesignh (Warmer) | kW | 2,2 | 2,1 |
| U | Back up heatingcapacity (Warmer) | kW | - | - |
| V | Declared capacity (Warmer) | kW | 2,2 | 2,1 |
| W | SCOP(Colder) | - | - | - |
| X | Energy efficiency class SCOP(Colder) | - | - | - |
| Y | Q_HE^3) heating season (Colder) | kWh/ a^II) | - | - |
| Z | Pdesignh (Colder) | kW | - | - |
| AA | Back up heating capacity (Colder) | - | - | - |
| AB | Declared capacity (Colder) | kW | - | - |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to §75].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
COMMISSION DELEGATED REGULATION (EU) No 626/2011 ^i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ^ii)
| A Supplier's name - | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | Samsung Electronics Co., Ltd. | |
| B Model name (Indoor/Outdoor) - | AR18TXFYAWKN/ AR18TXFYAWKX | AR24TXFYAWKN/ AR24TXFYAWKX | AR18TXHZAWKN/ AR18TXHZAWKX | |
| C Sound Power Level (Inside/Outside) dB(A) 58/65 62/68 58/65 | ||||
| D Refrigerant name ^1) | - R-32 R-32 R-32 | |||
| E GWP - 675 675 675 | ||||
| F | SEER | 6,8 | 6,4 | 6,8 |
| G | Energy efficiency class (SEER) | - | A++ | A++ |
| H | Q_CE^2) (cooling season) | kWh/ a^ii) | 257 | 355 |
| I | Pdesignc | kW | 5,0 | 6,5 |
| J | SCOP(Average) | - | 3,8 | 3,8 |
| K | Energy efficiency class SCOP (Average) | - | A | A |
| L | Q_HE^3) heating season (Average) | kWh/ a^ii) | 1400 | 1511 |
| M | Pdesignh (Average) | kW | 3,8 | 4,1 |
| N | Back up heating capacity (Average) | kW | - | - |
| O | Declared capacity(Average) | kW | 3,8 | 4,1 |
| P | Other heating seasons suitable for use | - | Warmer | Warmer |
| Q | SCOP(Warmer) | 4,8 | 4,6 | 4,8 |
| R | Energy efficiency class SCOP (Warmer) | - | A++ | A++ |
| S Q | _HE^3) heating season (Warmer) | kWh/ a^ii) | 613 670 613 | |
| T | Pdesignh (Warmer) | kW | 2,1 | 2,2 |
| U | Back up heatingcapacity (Warmer) | kW | - | - |
| V | Declared capacity (Warmer) | kW | 2,1 | 2,2 |
| W | SCOP(Colder) | - | - | - |
| X | Energy efficiency class SCOP (Colder) | - | - | - |
| Y | Q_HE^3) heating season (Colder) | kWh/ a^ii) | - | - |
| Z | Pdesignh (Colder) | kW | - | - |
| AA | Back up heating capacity (Colder) | - | - | - |
| AB | Declared capacity(Colder) | kW | - | - |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to §75].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO _2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
COMMISSION DELEGATED REGULATION (EU) No 626/2011 ^i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ^ii)
| A Supplier's name - | Samsung Electronics Co., Ltd. | |
| B Model name (Indoor/Outdoor) - | AR24TXHZAWKN/ AR24TXHZAWKX | |
| C Sound Power Level (Inside/Outside) dB(A) 62/68 | ||
| D Refrigerant name1) | - R-32 | |
| E GWP - 675 | ||
| F SEER 6,4 | ||
| G Energy efficiency class (SEER) | - | A++ |
| H Q_CE^2) (cooling season) | kWh/ a^(ii) | 355 |
| I Pdesignc | kW | 6,5 |
| J SCOP(Average) | - | 3,8 |
| K Energy efficiency class SCOP (Average) | - | A |
| L Q_HE^3) heating season (Average) | kWh/ a^(ii) | 1511 |
| M Pdesignh (Average) | kW | 4,1 |
| N Back up heating capacity (Average) | kW | - |
| O Declared capacity(Average) | kW | 4,1 |
| P Other heating seasons suitable for use | - | Warmer |
| Q SCOP(Warmer) | 4,6 | |
| R Energy efficiency class SCOP (Warmer) | - | A++ |
| S Q _HE^3) heating season (Warmer) | kWh/ a^(ii) | 670 |
| T Pdesignh (Warmer) | kW | 2,2 |
| U Back up heatingcapacity (Warmer) | kW | - |
| V Declared capacity (Warmer) | kW | 2,2 |
| W SCOP(Colder) | - | |
| X Energy efficiency class SCOP (Colder) | - | - |
| Y Q_HE^3) heating season (Colder) | kWh/ a^(ii) | - |
| Z Pdesignh (Colder) | kW | - |
| AA Back up heating capacity (Colder) | - | |
| AB Declared capacity (Colder) | kW | - |
1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times higher than 1 kg of CO₂, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3) Energy consumption "XYZ" kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
COMMISSION DELEGATED REGULATION (EU) No 626/2011 ^i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ^ii)
| [ESPAÑOL-ES] [FRANÇAIS-FR] | |||
| A | Nombre del proveedor Nom du fournisseur | ||
| B | Nombre del modelo(unidad interior/exterior) Nom du modèle(intérieur/extérieur) | ||
| C | Nivel de potencia acústica (interior/exterior) | Niveau de puissance acoustique (intérieur/extérieur) | |
| D | Nombre del refrigerante1) | Nom du fluide frigorigène1) | |
| E | GWP GWP | ||
| F | SEER SEER | ||
| G | Clase de eficiencia energética (SEER) Classe d'efficacité énergétique (SEER) | ||
| H | Q_CF^2) (temporada refrigeración) Q | _CF^2) (saison froide) | |
| I | Pdesignc Pdesignc | ||
| J | SCOP (Media) SCOP (moyenne) | ||
| K | Clase de eficiencia energética SCOP (Media) Classe d'efficacité énergétique SCOP (moyenne) | ||
| L | Q_HE^3) temporada calefacción (Media) Q | _HE^3) saison chaude (moyenne) | |
| M | Pdesignh (Media) Pdesignh (moyenne) | ||
| N | Copia de seguridad de capacidad de calefacción (Media) | Sauvegarder la capacité de chauffage (moyenne) | |
| O | Potencia declarada (Media) Puissance frigorifique déclarée (moyenne) | ||
| P | Otras temporadas de calefacción declaradas aptas para funcionar | Adapté à d'autres saisons chaudes | |
| Q | SCOP (Más cálida) SCOP (plus chaude) | ||
| R | Clase de eficiencia energética SCOP (Más cálida) | Classe d'efficacité énergétique SCOP (plus chaude) | |
| S | Q_IE^3) temporada calefacción (Más cálida) Q | _IE^3) saison chaude (plus chaude) | |
| T | Pdesignh (Más cálida) | Pdesignh (plus chaude) | |
| U | Copia de seguridad de capacidad de calefacción (Más cálida) | Sauvegarder la capacité de chauffage (plus chaude) | |
| V | Potencia declarada (Más cálida) | Puissance frigorifique déclarée (plus chaude) | |
| W | SCOP (Más fría) | SCOP (plus froide) | |
| X | Clase de eficiencia energética SCOP (Más fría) | Classe d'efficacité énergétique SCOP (plus froide) | |
| Y | Q_HE^3) temporada calefacción (Más fría) | Q_HE^3) saison chaude (plus froide) | |
| Z | Pdesignh (Más fría) | Pdesignh (plus froide) | |
| AA | Copia de seguridad de capacidad de calefacción (Más fría) | Sauvegarder la capacité de chauffage (plus froide) | |
| AB | Potencia declarada (Más fría) | Puissance frigorifique déclarée (plus froide) | |
| i | REGLAMENTO DELEGADO (UE) No 626/2011 DE LA COMISION | RÈGLEMENT DÉLÉGUÉ (UE) No 626/2011 DE LA COMMISSION | |
| ii | Ficha del producto (etiquetado energético de los acondicionadores de aire) | Fiche produit (l'indication, par voie d'étiquetage, de la consommation d'énergie des climatiseurs) | |
| iii | kWh/a | kWh/a | |
| iv | Warmer | Más cálida | Plus chaude |
| Colder | Más fría | Plus froide | |
| Warmer & Colder | Más cálida & Más fría | Plus chaude & Plus froide | |
COMMISSION DELEGATED REGULATION (EU) No 626/2011 ^i) PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) ^ii)