PHILIPS PowerLife FC8452 - Vacuum Cleaner

PowerLife FC8452 - Vacuum Cleaner PHILIPS - Free user manual and instructions

Find the device manual for free PowerLife FC8452 PHILIPS in PDF.

📄 48 pages English EN Download 💬 AI Question 11 questions ⚙️ Specs
Notice PHILIPS PowerLife FC8452 - page 6
View the manual : Français FR English EN Қазақша KK Русский RU Українська UK
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Philips
Model PowerLife FC8452
Appliance type Canister vacuum cleaner
Power supply Mains, nominal voltage 220-240 V
Suction power Electronically adjustable
Bag type S-bag® disposable or reusable (depending on country)
Bag capacity Not specified, Philips standard
Filters Motor protection filter + exhaust microfilter
Cord length Approx. 6 m (estimated)
Operating range Approx. 9 m (estimated)
Tube Telescopic
Included brushes Standard brush (hard floors/carpets), hard floor brush, Turbo mini-brush, crevice tool, small nozzle
Special features Full bag indicator, cord rewind, floor selector
Noise level Not specified
Maintenance Clean motor filter (1x/year), replace microfilter (every 12 months), empty/replace bag
Safety Do not vacuum liquids, hot ashes, flammable objects; do not use without bag/filter
Spare parts S-bag bags (FC8021, FC8022, FC8023), microfilter (4322 004 93681), motor filter (4322 004 93671)
Warranty International warranty, contact consumer service

Frequently Asked Questions - PowerLife FC8452 PHILIPS

What type of bag should I use for the Philips PowerLife FC8452?
Use only Philips S-bag® bags. References are: FC8021 (classic), FC8022 (high filtration), FC8023 (anti-odor). Depending on the country, a washable reusable bag may be supplied (ref. 4322 004 93370).
How do I replace the vacuum cleaner bag?
Open the cover, tilt the bag holder forward, pull the cardboard part of the bag to remove it (it closes automatically). Insert the new bag into the grooves of the holder, tilt the holder back and close the cover.
When should I change the bag?
Replace the bag as soon as the full bag indicator changes color, even if the brush is not on the floor.
How do I clean the motor protection filter?
Open the cover, remove the bag, then the filter holder and the filter. Shake the filter over a trash bin. Put the filter back in its holder, then place the assembly back in the appliance. Clean it at least once a year.
How often should I replace the exhaust microfilter?
The exhaust microfilter should be replaced every 12 months. Open the microfilter grille, remove the old one, insert the new one and close the grille.
What should I do if the suction power decreases?
Check: the bag may be full (replace it), the filters may be dirty (clean or replace), the power setting may be too low (increase it), or the nozzle/tube/hose may be blocked (remove the obstruction).
Can I vacuum water or liquids with this vacuum cleaner?
No, never vacuum water, liquids, flammable substances or hot ashes. This would damage the appliance and be dangerous.
How do I use the Turbo mini-brush?
The Turbo mini-brush is designed for furniture and mattresses to remove pet hair and dust. Do not use it on animals. To clean the internal brush, turn off and unplug the appliance, cut wrapped hair and threads with scissors, then remove the debris.
How do I store the vacuum cleaner?
Turn off and unplug the appliance. Press the cord rewind button. Place the appliance in vertical position and insert the nozzle wedge into the storage insert. Set the telescopic tube to the shortest for more stability.
Where can I find accessories and spare parts?
Go to a Philips dealer, an authorized Philips Service Center, or contact the Consumer Service in your country. You can also visit www.philips.com/support. Filter and bag references are indicated in the manual.

User questions about PowerLife FC8452 PHILIPS

1 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

How to change or maintain the filters of the PHILIPS PowerLife FC8452?
Frequently Asked Questions - 23 d
Response Notice-Facile

The PHILIPS PowerLife FC8452 has two filters that need regular maintenance to ensure proper functioning:

Motor Protection Filter

Frequency: Minimum cleaning once a year

  • Open the cover by pulling it
  • Remove the bag from the device
  • Detach the filter holder and the motor protection filter
  • Remove the filter from its holder and shake it over a bin to clean it
  • Reinstall the filter in its holder, then put the assembly back in place
  • Replace the bag and close the cover

Part reference: 4322 004 93671

Exhaust Microfilter

Frequency: Replacement every 12 months

  • Unplug the device
  • Open the exhaust microfilter grille
  • Remove the old filter and insert the new one
  • Align the tabs of the grille with the slots of the device, then press until it clicks

Part reference: 4322 004 93681

Important: Never operate the device without a bag or without the motor protection filter, as this will damage the motor and reduce its lifespan.

Respond (be the first)

Download the instructions for your Vacuum Cleaner in PDF format for free! Find your manual PowerLife FC8452 - PHILIPS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PowerLife FC8452 by PHILIPS.

USER MANUAL PowerLife FC8452 PHILIPS

PHILIPS

Diagram of three open panels with grid patterns and curved arrows indicating rotation or movement (no text or symbols)

Exploded view diagram of a vacuum cleaner with numbered parts for identification

ENGLISH 6

FRANÇAIS 11

ҚАЗАҚША 16

РУССКИЙ 22

УКРАЇНСЬКА 28

PHILIPS PowerLife FC8452 - PHILIPS - 3

38

PHILIPS PowerLife FC8452 - PHILIPS - 4

Introduction

Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome.

General description (Fig. 1)

1 Cover
2 Cord rewind button
3 Dustbag full indicator
4 Electronic suction power control
5 On/off button
6 Rear wheel
7 Hose connector
8 Hose connection opening
9 Cover release tab
10 Handle
11 Dustbag
12 Motor protection filter
13 Motor protection filter holder
14 Motor inlet
15 Swivel wheel
16 Type plate
17 Storage slot
18 Mains cord with plug
19 Exhaust micro filter grille
20 Exhaust micro filter
21 Parking slot
22 Rocker switch for carpet/hard floor settings
23 Combination nozzle
24 Mini turbo brush (specific types only)
25 Crevice nozzle (specific types only)
26 Small nozzle (specific types only)
27 Hard floor nozzle (specific types only)
28 Telescopic tube
29 Accessory holder (specific types only)
30 Hose with handgrip

Important

Read this user manual carefully before you use the appliance and save it for future reference.

Danger

- Never suck up water or any other liquid. Never suck up flammable substances and do not suck up ashes until they are cold.

Warning

  • Check if the voltage indicated on the appliance corresponds to the local mains voltage before you connect the appliance.
  • Do not use the appliance if the mains cord, the plug or the appliance itself is damaged.
  • If the mains cord is damaged, you must have it replaced by Philips, a service centre authorised by Philips or similarly qualified persons in order to avoid a hazard.
  • The plug must be removed from the socket-outlet before cleaning or maintaining the appliance.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance.
  • Do not point the hose, the tube or any other accessory at the eyes or ears nor put it in your mouth when it is connected to the vacuum cleaner and the vacuum cleaner is switched on.
  • Do not clean any part of the vacuum cleaner in the dishwasher.

Caution

  • Do not suck up large objects as this may cause the air passage in the tube or hose to become obstructed.
  • When you use the vacuum cleaner to vacuum ashes, fine sand, lime, cement dust and similar substances, the pores of the dustbag and the motor protection filter become clogged. If you notice a strong decrease in suction power, replace the dustbag and clean the motor protection filter.
  • Never use the appliance without a dustbag or the motor protection filter. This could damage the motor and shorten the life of the appliance. Only use Philips s-bag ® dustbags or Philips reusable dustbag.
  • Do not use the mini turbo brush on pets.

Electromagnetic fields (EMF)

This Philips appliance complies with all standards regarding electromagnetic fields (EMF). If handled properly and according to the instructions in this user manual, the appliance is safe to use based on scientific evidence available today.

Preparing for use

Hose

1 To connect the hose, push the hose connector into the hose connection opening ('click') (Fig. 2).
2 To disconnect the hose, press the release buttons (1) and pull the hose connector out of the hose connection opening (2) (Fig. 3).

Telescopic tube

Note: You can connect any of the nozzles or accessories to the handgrip or to the tube. To do this, insert the handgrip or tube into the nozzle or accessories while turning a little.

1 Push the handgrip into the suction tube. (Fig. 4)
To remove it, turn the handle slightly and pull it off the tube.

2 Adjust the telescopic tube to the length you find most comfortable during vacuuming. Press the slide on the tube (1) and push the lower tube part downwards or pull it upwards (2) (Fig. 5).

Combination nozzle

You can use the combination nozzle on carpet (with the brush strips folded in) or on hard floors (with the brush strips folded out).

Hard floor nozzle (specific types only)

- The hard floor nozzle is designed for gentle cleaning of hard floors (Fig. 6).

ENGLISH8

Accessory holder (specific types only)

1 To store accessories in the accessory holder, push them onto the holder (Fig. 7).

Mini turbo brush (specific types only)

The mini turbo brush is specially designed for effectively picking up animal hairs and fluff from furniture and mattresses.

Crevice nozzle and small nozzle (specific types only)

  • Use the crevice nozzle to clean narrow corners or hard-to-reach places.
  • Use the small nozzle to clean small areas, e.g. the seats of chairs and sofas.

Using the appliance

Vacuum cleaning

1 Pull the cord out of the appliance and insert the mains plug into the wall socket.
2 Press the on/off button on top of the appliance with your foot to switch on the appliance (Fig. 8).

Note: If you want to pause for a moment, insert the ridge on the nozzle into the parking slot to park the tube in a convenient position (Fig. 9).

Adjusting suction power

- You can adjust the suction power with the electronic suction power control on the vacuum cleaner (Fig. 10).

Cleaning and maintenance

The plug must be removed from the socket-outlet before cleaning or maintaining the appliance.

1 Clean the appliance and its parts with a damp cloth.
Do not clean any part of the vacuum cleaner in the dishwasher.

Cleaning the motor protection filter

To maintain optimal performance, clean the motor protection filter at least once a year.

1 Pull the cover upwards to open it (Fig. 11).
2 Lift the dustbag out of the appliance (Fig. 12).
3 Pull the filter holder with the motor protection filter out of the appliance (Fig. 13).
4 Take the motor protection filter out of the holder and shake the motor protection filter over a dustbin to clean it.
5 Put the filter in the filter holder and slide the filter holder back into the appliance.
6 Put the dustbag back into the appliance, and close the cover.

Cleaning the mini turbo brush (specific types only)

To clean the brush inside the mini turbo brush, follow the steps below:

1 Switch off and unplug the appliance.
2 Rotate the brush inside the mini turbo brush until the cutting groove faces you. Use a pair of scissors to cut the hairs, threads etc that have collected around the brush. (Fig. 14)
3 Remove fluff, hairs and other dirt from the brush.

Emptying the reusable washable dustbag (specific countries only)

In some countries, this vacuum cleaner comes with a reusable washable dustbag. You can use this dustbag instead of disposable dustbags. To remove and insert the reusable dustbag, follow the instructions in chapter 'Replacing the dustbag'.

To empty the dustbag:

1 Slide the clip off the dustbag sideways.
2 Shake out the contents into a dustbin.
3 To close the dustbag, slide the clip back onto the bottom edge of the dustbag.

Replacement

The plug must be removed from the socket-outlet before cleaning or maintaining the appliance.

Replacing the disposable dustbag

  • Replace the dustbag as soon as the dustbag-full indicator has changed colour permanently, i.e. even when the nozzle is not placed on the floor (Fig. 15).
    1 Pull the cover upwards to open it and tilt the dustbag holder forward. (Fig. 11)
    2 Pull at the cardboard tag to remove the full dustbag from the holder (Fig. 16).
    When you do this, the dustbag is sealed automatically.
    3 Slide the cardboard front of the new dustbag into the two grooves of the dustbag holder as far as possible (Fig. 17).
    4 Tilt the dustbag holder backward (Fig. 18).

Note: If no dustbag has been inserted, you cannot close the cover.

5 Push the cover downwards to close it.

Replacing the exhaust micro filter

Always unplug the appliance before you replace a filter.

Replace the exhaust micro filter every 12 months.

1 The plug must be removed from the socket-outlet.
2 Open the exhaust micro filter grille.
3 Remove the filter and place the new filter in the appliance.

4 To close the exhaust grille, first align the lugs on the bottom of the grille with the slots in the appliance (1). Then press the tab back on the appliance until the grille locks into place (2) ('click') (Fig. 19).

Ordering accessories

To purchase accessories for this appliance, go to your Philips dealer, Philips service centre or contact the Philips Consumer Care Centre in your country. You can also visit www.philips.com/support.

Ordering dustbags

  • Philips Classic s-bag ® synthetic dustbags are available under type number FC8021.
  • Philips Clinic s-bag ® high filtration synthetic dustbags are available under type number FC8022.
  • Philips Anti-odour s-bag ® synthetic dustbags are available under type number FC8023.
  • Reusable washable dustbags (some countries only) are available under code number 4322 004 93370.

Note: Please visit www.s-bag.com for more information about the s-bag.

Ordering filters and accessories

  • Exhaust micro filters are available under service number 4322 004 93681.
  • Motor protection filters are available under service number 4322 004 93671.

Storage

1 Switch off and unplug the appliance, and pres the cord rewind button to rewind the cord (Fig. 20).
2 Put the appliance in upright position. To attach the nozzle to the appliance, insert the ridge on the nozzle into the storage slot.

Note: To ensure stable storage of the telescopic tube, adjust the tube to the shortest length.

Environment

- Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment (Fig. 21).

Guarantee and service

If you need service or information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Centre in your country. You find its phone number in the worldwide guarantee leaflet. If there is no Consumer Care Centre in your country, go to your local Philips dealer.

Troubleshooting

1 The suction power is insufficient

  • Perhaps the dustbag is full.
    If necessary, replace or empty the dustbag.
  • Perhaps the filters need to be cleaned or replaced.
    If necessary, clean or replace the filters.
  • Perhaps the electronic suction power control is set to a low setting.
    Set the control to a higher setting.
  • Perhaps the nozzle, tube or hose is obstructed.
    Remove the obstruction.

2 Specific types only: hairs are entangled around the brush inside the mini turbo brush.

- Clean the mini turbo brush. See chapter 'Cleaning', section 'Cleaning the mini turbo brush'.

Introduction

The image is too blurry to recognize any text content.

PHILIPS PowerLife FC8452 - The image is too blurry to recognize any text content. - 1

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PHILIPS

Model : PowerLife FC8452

Category : Vacuum Cleaner