USER MANUAL AC200L BLUETTI
Portable Power Station
User Manual v2.0
Please read this manual carefully before use and keep it for future reference.

Warning
- Charge the unit before first use.
- Do not use solar panels with open circuit voltage higher than 145VDC. Solar input voltage range for the unit is 12V-145VDC.
- Charge the unit immediately when the SoC drops below 5% . If the SoC drops to 0, power off the unit and charge it for at least 30 minutes before restarting.
- The unit is for off-grid use only. Do not connect its AC output to the grid.
- If not used for more than 3 months, charge the unit to 40% - 60% SoC and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months.
Thank You!
Thank you for making BLUETTI a part of your family.
From the very beginning, BLUETTI has tried to stay true to a sustainable future through green energy storage solutions while delivering an exceptional eco-friendly experience for our homes and our world.
That's why BLUETTI makes its presence in 100+ countries and is trusted by millions of customers across the globe.

Copyright © Shenzhen PowerOak Newener Co., Ltd. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without the prior written consent of Shenzhen PowerOak Newener Co., Ltd.
Notice
BLUETTI's products, services, and features are subject to the agreed-upon terms and conditions during purchase. Please note that some products, services, or features described in this manual may not be available under your purchase contract. Unless otherwise specified in the contract, BLUETTI makes no representations or warranties of any kind, express or implied, with respect to the contents of this manual.
The contents of this manual are subject to change without notice. Please get the latest version from official BLUETTI website.
If you have any questions or concerns about this manual, please contact BLUETTI support for further assistance.
Contents
1 Safety Instructions 05
2 Packing List 09
3 Product Introduction 11
4 Product Overview 12
5 Power ON/OFF 13
6 LED Screen 14
7 Charging 16
8 Discharging 19
9 Settings 20
10 Connect to Expansion Battery 24
11 BLUETTI App 25
12 Specifications 25
13 Button Operation Instructions 27
14 Troubleshooting 28
Appx. 1 Estimating Operation Time 30
Appx. 2 FAQ 31
Appx. 3 FCC Statement 32
Appx. 4 IC Caution 33
Appx. 5 Consignes de sécurité 34
1. Safety Instructions
Read this manual for instructions on the proper use and safety information for the product. The safety instructions provided herein are for illustrative purposes that include but are not limited to those listed in this manual. Actual operation shall comply with all applicable safety standards. If you have any questions, feel free to contact BLUETTI support or your local BLUETTI dealers.
1.1 Statement
To ensure a safe operation, it's crucial to observe and adhere to the following conditions:
- Always operate or store the product in the conditions specified in this manual.
- Avoid unauthorized disassembly, component replacement, or modification of software codes.
BLUETTI shall not be liable for damages resulting from the following circumstances:
- Force majeure events such as earthquakes, fires, storms, floods, or mudslides.
- Damage caused by the customer's own transportation.
- Damage resulting from inadequate storage conditions as specified in the manual.
- Damage caused by customer negligence, improper operation, or intentional actions.
- System or hardware damage caused by third parties or customers, including but not limited to improper handling and installation not in accordance with the instructions in this manual.
- Usage of the product with devices that require a high-performance Uninterruptible Power Supply (UPS), including but not limited to data servers, workstations, medical equipment, and other similar devices.
1.2 General Requirements
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS
WARNING:
When using this product, basic precautions should always be followed, including the following:
- Read all the instructions before using the product.
- To reduce the risk of injury, close supervision is necessary when the product is used near children.
- Do not put fingers or hands into the product. And do not insert foreign objects into any
ports of the product.
- Use of an attachment not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or injury to persons.
- To reduce the risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the product.
- Do not use a battery pack or appliance that is damaged or modified, as they may exhibit unpredictable behavior resulting in fire, explosion, or personal injury.
- Do not operate the product with a damaged cord or plug, or a damaged output cable.
- Do not attempt to replace the internal battery or any other component of the product by anyone other than authorized personnel. There are no end-user serviceable components. Do not disassemble the product, take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock.
- To reduce the risk of electric shock, unplug the product from the outlet before attempting any instructed servicing.
- WARNING - RISK OF EXPLOSIVE GASES. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and engines.
PERSONAL PRECAUTIONS
a. Wear complete eye protection and clothing protection. Avoid touching eyes while working near the battery.
b. Never smoke or allow a spark or flame in the vicinity of the battery or engine.
c. Be extra cautious to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit the battery or other electrical parts which may cause an explosion. - When charging the internal battery, work in a well ventilated area and do not restrict ventilation in any way.
- Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
- Do not expose the product to fire or excessive temperature. Exposure to fire or temperature above 80^ C ( 176^ F ) may cause an explosion.
-
Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that safety is maintained.
-
Do not stack anything on top of the product while in storage or while in use. Do not move the product while operating as vibrations and sudden impacts may lead to poor connections to the hardware inside.
- In case of fire, use only a dry powder fire extinguisher appropriate for the product.
- WARNING - RISK OF ELECTRIC SHOCK. Never use the product to supply power tools to cut or access live parts or live wirings, or materials that may contain live parts or live wirings inside, such as building walls, etc.
1.3 Grounding Instructions
The product is designed for portable use and typically does not require earth grounding. However, if you connect it to the power grid, it's important to ensure proper grounding for safety. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with an AC power cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product - if it does not fit the outlet, have a proper outlet installed by a qualified electrician.
1.4 Handling Requirements
During transportation or storage, take care to avoid dropping, violently impacting, or tilting the product as it may result in internal damage. If necessary, use mechanical assistance such as carts or adjustable height workbenches to ensure safe handling.
Recommended number of people based on the weight of product
| Weight | Number of people |
| <18kg (39.7lbs) | 1 |
| 18kg~32kg (39.7lbs~70.5lbs) | 2 |
| 32kg~55kg (70.5lbs~121.3lbs) | 3 |
| >55kg (121.3lbs) | 4 or a cart |
1.5 Storage Instructions
- When the SoC drops to 5% , please charge the product immediately.
-
Before storing the product, charge it to 40 % to 60 % SoC to keep it in optimal condition. In addition, power off the unit and disconnect all electrical connections from it.
-
Store the product in a cool and dry place, keeping it away from flammable or combustible materials and gases.
- The product can be safely stored within a temperature range of -20^ to 45^ (-4°F to 113°F). However, if the storage duration exceeds one month, it's recommended to maintain an ideal storage temperature of around 30^ (86°F).
- Fully cycle the product every 3 months to maintain the battery's health. It's NOT recommended to store the unit for extended periods of time, as it may affect its performance and overall lifespan.
If the SoC drops to 0 (during storage or upon startup), take the following actions to safely restart the product:
- Shut down immediately.
- Charge within 48 hours.
- Keep it at an ambient temperature of 5^ C to 35^ C (41°F to 95°F) for 6 hours before charging. It's recommended to charge the product via an AC source. If charging via solar energy, ensure that your solar system provides an output of more than 100W.
The symbol displayed is intended to remind you to read the instructions in the literature accompanying the product before operation and maintenance.
- Connect the product to a socket-outlet that has an earthing connection using the power cord provided.
- The socket-outlet should be installed near the product and easily accessible for safety purposes.
- Never dispose of a battery by throwing it into fire or a hot oven, or by mechanically crushing or cutting it, as these may cause it to explode.
- Avoid leaving batteries in extremely high-temperature environments, as this can result in an explosion or the leakage of flammable liquid or gas.
- The battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas.
- Attention should be drawn to the environmental aspects of battery disposal.
- Please refer to the information on the exterior bottom enclosure for electrical and safety information before installing or operating the apparatus.
SAVE THESE INSTRUCTIONS
BLUETTI shall not be liable for any equipment damage caused by the violation of the above instructions.
2. Packing List
Standard Accessories
| Item | Picture | Qty. |
| AC200L Portable Power Station | 1 | |
| AC Charging Cable (15A) | 1 | |
| DC Input Cable (Work with solar / car / lead-acid battery charging cable) | 1 | |
| Solar Charging Cable | 1 | |
| Car Charging Cable | 1 | |
| Grounding Screws (M5×10) | 1 | |
| Product Documentation | 1 | |
| Warranty Card | 1 |
Optional Accessories
(Available on the official BLUETTI website: https://www.bluettipower.com)
| Item | Picture |
| USB-C to USB-C Cable (output) | |
| B300 Expansion Battery | |
| B210 Expansion Battery | |
| B230 Expansion Battery | |
| B210 Expansion Cable | |
| 12V DC Power Cable (For 12V devices with DC5521 port, such as routers, cameras, etc.) | |
| 48V DC Power Cable (for D40) |
D40 Voltage Regulator

Lead-acid Battery Charging Cable
(Charge the AC200L via a
lead-acid battery)

30A AC Charging Cable

3. Product Introduction
Introducing the BLUETTI AC200L - a high-capacity power station that packs a powerful punch. With its impressive 2,048Wh capacity and 2,400W pure sine wave output, this powerhouse can effortlessly charge your laptop, run your fridge, and power your essential tools.
What sets the AC200L apart is its exceptional flexibility, allowing you to tailor it to your requirements. You have the option to link up with BLUETTI's expansion batteries - the B210, B230, and B300 - enabling you to expand your energy capacity according to your unique demands. By using two B300 units, you can elevate your total power capacity to a staggering 8,192Wh, making the AC200L the perfect companion for any power-intensive adventure.
Whether you're off-grid camping, carrying out fieldwork, or simply need a reliable backup for home power outages, the BLUETTI AC200L is your robust and trustworthy power solution. Power your life, wherever you are.
Danger:
Do not connect the AC output of AC200L to the grid.
4. Product Overview

(1) Cigarette Lighter Port
(2) Power Button
③ DC Power Button
④ LED Screen
(5) AC Power Button
(6) 20A AC Outlet
(7) 30A AC Outlet
⑧ USB Power Button
⑨ USB-C Port
⑩ USB-A Port
(1) USB-C Port
12 48V DC Port
⑬ Circuit Breaker
(14) Grounding Pole
(15) AC Input
(16) DC Input
(17) Battery Expansion Port
5. Power ON / OFF

Attention:
Please place the unit on the platform firmly and stably.
- Power ON: Press the Power Button, the button lights up indicating that the AC200L is now on standby.
- Power OFF: Press and hold the Power Button for about 2 seconds to turn off the unit.
- AC ON / OFF: When the AC200L is on, press the AC Power Button to turn it on / off.
- DC ON / OFF: When the AC200L is on, press the DC Power Button to turn it on / off.
- USB ON / OFF: When the AC200L is on, press the USB Power Button to turn it on / off.
- Restart: Power off the AC200L first, then press the Power Button to restart.
Note: When the AC200L is on, you can activate the LED screen by interacting with any of the buttons.

6. LED Screen
The AC200L features an informative LED screen that offers easy access to all the essential information about the unit's status and performance. When you power on the unit, the LED screen lights up, and when you power off the unit, the screen turns off as well.

(1) Expansion Battery
(2) Charge / Discharge Progress
(3) Turbo Charging
(4) ECO Mode
⑤ Battery Capacity (SoC)
(6) Silent Charging
(7) DC Input
⑧ Bluetooth Connection
⑨ WiFi Connection
10 Fan Status
(1) AC Input Power
(12) AC Output Power
(13) AC Output Voltage
(14) AC Output Frequency
⑮ Grid Connection
(16) DC Output
(17) AC Output
(18) Power Lifting Mode
Charge / Discharge Remaining Time
(20) Charge / Discharge Status
(2) Low Temperature Alert
(2) High Temperature Alert
(23) Overcurrent Alert
Overload Alert
(25) Fault Alert
(26) DC Output Power
(27) Low Battery Alert
(28) DC Input Power
| LCD Instructions | |
| Startup | LCD lights up |
| Shutdown | LCD lights off |
| Each icon represents an attached expansion battery. The AC200L can display up to 2 battery icons. | |
| The bar increases during charging and decreases during discharging. | |
| The AC200L is charging in Turbo Charging Mode. | |
| The ECO Mode is enabled to save power. | ECO |
| The remaining battery capacity. | |
| The AC200L is charging in Silent Charging Mode. | |
| The AC200L is charging from a DC power source, such as solar panels, lead-acid batteries, etc. | |
| The AC200L connects to BLUETTI App via Bluetooth. | |
| The AC200L connects to BLUETTI App via WiFi. | |
| When it lights up, the fan is activated and working properly. If it flashes, there may be a problem with the fan. | |
| The real-time AC charging power. | |
| The real-time total AC output power. | |
| The real-time AC output voltage. | VAC |
| The real-time AC output frequency. | Hz |
| The AC200L is charging from the home grid. | GRID |
| The DC output is turned on. | DC |
| The AC output is turned on. | AC |
| The AC200L is operating in Power Lifting Mode. | |
| The remaining time of charging or discharging. | 88.BH |
| :Charging : Discharging | |
| The temperature inside the unit is lower than -20°C (-4°F). | |
| The temperature inside the unit is higher than 70°C (158°F). | |
| The AC200L is drawing too much current, which can cause damage to the unit or any connected devices. | |
| The AC200L is overloaded. | |
| There's an issue with the AC200L, which may require troubleshooting or repair. | |
| The real-time DC output power. | |
| The SoC drops below 5%. | |
| The real-time DC input power. | |
7. Charging
AC200L supports five charging methods: AC, solar, car, generator, and Lead-acid battery.
! Attention:
- Double-check that all cables are firmly plugged in.
- Avoid getting the plug and socket wet to prevent any potential damage.
7.1 AC Charging
Plug the AC200L into a standard wall outlet and start charging. Once it's fully charged, the AC200L automatically stops charging to prevent overcharging. For a fast charge, you can enable Turbo Charging in the BLUETTI App, which allows for an 80% capacity in just 45 minutes at an ambient temperature of 25^ ( 77^ ).

7.2 Solar Charging
Connect the solar panels (in series) to AC200L via the DC input cable and solar charging cable. When solar panels maintain a power output of 1,200W, the AC200L can be charged up to 80% in about 1.5 hours. However, please be aware that the charging time may vary based on weather conditions, sunlight intensity, panel orientation, and other variables.
Note:
- Make sure your solar panels meet the following requirements:
Voc: 12V-145V Current: 15A Max. Power: 1,200W Max.
- Non-waterproof solar panels will lose efficiency if they get exposed in the rain for a long time.

7.3 Car Charging
Connect the AC200L to the vehicle's 12V cigarette lighter port via the DC input cable and car charging cable. The AC200L can charge at a maximum of 96W, and it'll automatically stop charging once it's fully charged.
Note: Make sure your vehicle meets the following conditions for charging:
- The vehicle is capable of supplying power.
- The vehicle's engine is running during the charging process.

i Attention:
The AC200L has a low-voltage disconnect function designed to protect your vehicle's battery during charging. If the input voltage drops below 10.5V, the unit will automatically stop charging to prevent over-discharging and potential damage to the battery.
7.4 Generator Charging
Connect the AC200L to a generator via the AC charging cable. The AC200L also automatically stops charging when it's fully charged.

Note: Make sure your generator delivers the AC output with charging voltage, frequency, and Grid Self-adaption Mode voltage that meet AC200L's specifications.
If the total power demand of your connected devices exceeds the generator's output capacity, please turn on the Grid Self-adaption Mode to ensure a seamless charging experience.
7.5 Lead-acid Battery Charging
In this method, the AC200L is charged by connecting the lead-acid battery and the AC200L DC/PV port via the optional lead-acid battery charging cable, as shown in the figure below.

8. Discharging
Besides the cigarette lighter port, USB-A, and USB-C, AC200L also features two types of AC outlets and a 48V DC port, expanding your charging options.
8.1 AC Discharging
| Port | Picture | Description |
| 20A AC Outlet x4 | ○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○ | For AC electrical devices. |
| 30A AC Outlet x1 | ○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○ | For AC electrical devices with NEMA TT-30 plug. |
8.2 DC Discharging
| Port | Picture | Specifications | Description |
| Cigarette Lighter Port x 1 | 12V/10A | 12V DC appliances up to 120W power. e.g. car refrigerator, air conditioner, lead-acid battery | |
| USB-A x 2 | QC 3.0, 18W Max. | Mobile phones and other small loads. | |
| USB-C x 2 | PD 3.0, 100W Max. | Mobile phones, laptops, etc. | |
| 48V DC Port x 1 | 44.8V-57.6V/8A | 48V DC appliances, e.g. charging RV Life Batteries with D40 |
Note: To ensure optimal performance, avoid short-circuiting the ports and keep them dry during use or storage. Additionally, do not block or cover the ports while ensuring proper ventilation.
9. Settings
The AC200L offers the convenience of adjusting its settings either via the LED screen or the BLUETTI App. With the unit's LED screen, you have direct control over various settings such as Power Lifting Mode, ECO Mode, output frequency, and charging modes. Additionally, by using the BLUETTI App, you can access a user-friendly interface on your phone to conveniently monitor and control the AC200L.
9.1 Setting Mode
When the screen is on, press and hold the AC and DC Power Buttons for about 2 seconds till the output frequency flashes to enter the Setting Mode.
9.2 Frequency Switching
The current output frequency (50Hz / 60Hz) is displayed in the lower right corner of the screen. In the Setting Mode, press the DC Power Button to navigate until the output frequency appears on the screen. Then, press the AC Power Button to switch the frequency options based on your requirements.
Note: Turn off AC Power Button before setting Frequency.
9.3 AC Charging Mode
The AC200L supports 3 AC charging modes - Standard, Turbo, and Silent to fit your specific needs. In the Setting Mode, use the DC power button to navigate until the or ^Z icon starts flashing on the screen. Then, press the AC power button to choose the charging modes. Please refer to the table below for useful instructions.
| Mode | Recharging Power | Description | Note | Icon | ||
| AC | PV | AC+PV | ||||
| Standard | 1200W Max. | 1200W Max. | 1200W Max. | Fully charged in about 3 hours | More friendly to AC200L's battery. | None |
| Turbo | 2400W Max. | 1200W Max. | 2400W Max. | 80% charge in 45 minutes | Comes in handy when recharging time is a priority. | |
| Silent | 800W Max. | 800W Max. | 800W Max. | Low operation noise less than 50dB | Offers a quiet, low-power operation for long battery life. | |
9.4 Power Lifting Mode
The Power Lifting Mode is specifically designed to handle resistive loads up to 3,600W, including electric blankets, kettles, hairdryers, and other heating devices. To enable it, access the Setting Mode, navigate with the DC Power Button until the appears, and press the AC Power Button to enable the mode.
Note: The Power Lifting Mode is not enabled by default and is only suitable for resistive loads with a power rating between 2,400W-3,600W.
Although the AC200L can handle higher power demands, its actual operating power remains at 2,400W.
9.5 ECO Mode
The AC200L has three ECO modes that help you save power and extend battery life:
- AC-ECO Mode
In this mode, if the AC power output falls below a certain level for a set period of time, the AC power will automatically turn off.
Note: This mode is not available when the AC200L is charging from an AC source like a wall outlet or generator.
- DC-ECO Mode
In this mode, if the DC power output falls below a certain level for a set period of time, the DC power will automatically turn off.
i Attention:
- The AC-ECO and DC-ECO modes are enabled by default to save energy, and it's recommended to keep them enabled at all times.
- Use the BLUETTI App to enable or disable AC-ECO Mode and DC-ECO Mode separately. If you use the LED screen, they'll be turned on or off at the same time.
- To avoid any interruption in charging, disable ECO Mode when charging a small device that consumes less than 60W of power.
In the Setting Mode, press the DC Power Button to navigate through the setting items. When the ECO icon flashes on the screen, press the AC Power Button to enable or disable the ECO Mode.
9.6 WiFi & Bluetooth Connection
To connect the AC200L to the BLUETTI App, turn on the WiFi or Bluetooth first. In the Setting Mode, press the DC Power button to navigate through the setting items. When the × icon flashes on the screen, press the AC Power Button to turn Bluetooth on. Similarly, when the icon flashes on the screen, press the AC Power Button to toggle WiFi on.
9.7 UPS Mode
With the UPS mode enabled, the AC200L can provide uninterrupted power to your essential appliances during a power outage. And there are four different modes available through the BLUETTI App, allowing you to choose the best option for your needs.
- Standard UPS Mode
In this mode, the AC200L and its expansion batteries (if any) are always charged using available solar or grid power, ensuring that they are ready to provide backup power in case of a grid failure. When the grid fails, the AC200L unit seamlessly takes over to keep your devices running without any interruption.
Time Control UPS Mode
This mode allows you to program the AC200L to charge during off-peak hours when electricity is cheaper. Then, during peak hours when electricity is more expensive, the AC200L seamlessly switches over to power your devices, helping you to save money on your electricity bills.
- PV Priority UPS Mode
The PV Priority UPS mode is better for regions with plenty of sunlight all the year. AC200L is mainly charged by solar energy to save power.
Note: When battery SOC is higher than the preset value, devices on AC outlets are powered by PV and the battery together.
When battery SOC is lower than set value, the grid charges the battery and devices at the same time.
- Customized UPS Mode
Tailor your UPS settings to match your unique needs in this mode. Create personalized schedules for charging and discharging, set battery SoC limits, and even control the grid
charging switch and scheduled charging switch according to your diverse requirements.
9.8 Grid Self-adaption Mode
If you can not charge the AC200L using a generator or unstable grid voltage because of unstable voltage, you can enable the Grid Self-adaption Mode through the BLUETTI App.
9.9 Max. Grid Input Current
The Max. Grid Input Current is set to 15A by default. If the grid current doesn't match this setting, adjust the setting in the BLUETTI App.
i Attention:
The AC200L allows a maximum grid input current of up to 20A.
If you need to increase the setting beyond the default 15A, please contact BLUETTI Customer Service and request a password to make the necessary adjustments.
9.10 Exit Setting Mode
To save your AC200L settings and exit the Setting Mode, press and hold both the DC and AC Power Buttons at the same time.
Note: If you do not perform any operation in 1 minute, the AC200L will automatically exit the Setting Mode, and no changes will be saved.
10. Connect to Expansion Battery
The AC200L unit supports several types of expansion batteries to increase its power capacity, such as the B210, B230, and B300. Follow the steps below to connect them:
- Make sure both the AC200L and the expansion battery are turned off.
- Connect them using the battery expansion cable.
- Power on the AC200L and the expansion battery turns on automatically. The 📁 🅕 displays on the AC200L's screen.

(AC200L +1 B300)
If you want to add one more expansion battery, please set up the system as shown.

(AC200L + 2 B300)
i Attention:
The AC200L is compatible with up to two B210 or B300 units, but only one B230 unit.
11. BLUETTI App
Scan the QR code below or search "BLUETTI" in the App Store or Google Play to download the BLUETTI App.

For more details, please refer to BLUETTI APP INSTRUCTIONS.
- Specifications
| Model | AC200L |
| Battery Capacity | 2,048Wh (40Ah) |
| Cell Type | Lithium Iron Phosphate (LiFePO4, LFP) |
| AC+DC/PV Input Power | 2,400W Max. |
| AC+DC Output Power(without grid) | 2,500W Max. |
| Weight | 28.3 kg/ 62.4 lb |
| Dimensions (L × W × H) | 420mm × 280mm × 366.5mm / 16.5in × 11in × 14.4in |
| Charging Temperature | 0°C to 40°C / 32°F to 104°F |
| Discharging Temperature | -20°C to 40°C / -4°F to 104°F |
| Storage Temperature | Up to 1 month: -20°C to 45°C / -4°F to 113°F Up to 3 months: -20°C to 30°C / -4°F to 86°F Up to 12 months: -20°C to 25°C / -4°F to 77°F |
| Working Humidity | 10% to 90% |
| Noise | 50dB Max. |
| Working Altitude | 2,000m / 6,561ft |
| AC Output | |
| Power | 2,400W in total |
| Overload Power | 2520W~3000W@2min |
| 3000W~3600W@5s | |
| >3600W@0.5s | |
| Voltage | 120VAC |
| Current | 20A |
| Frequency | 50Hz / 60Hz |
| DC Output | |
| Cigarette Lighter Port × 1 | 12VDC / 10A |
| USB-A × 2 | 5VDC / 3A, 9VDC / 2A, 12VDC / 1.5A, 18W Each |
| USB-C × 2 | 5/9/12/15/20VDC / 3A, 20VDC / 5A; (100W for one, 150W for two) |
| 48V DC Port × 1 | 48VDC / 8A |
| AC Input | |
| Voltage | 120VAC |
| Current | 20A Max. |
| Frequency | 50Hz / 60Hz |
| UPS | Switching time ≤20ms |
| Power | 2,400W Max. (0%-80% in 45 minutes @ 10°C-30°C / 50°F-86°F) |
| DC Input | |
| Interface | 2-pin Aviation Socket |
| Power | 1,200W Max. |
| Current | 15A Max. |
| Voltage | 12V to 145VDC |
| Battery Expansion Port | |
| Voltage | 44.8V to 57.6VDC |
| Input Current | 60A Max. |
- Button Operation Instructions
| Operation | Function | Description |
| Press the AC Power Button | Turn on / off the AC output | / |
| Press the DC power button | Turn on / off the cigarette lighter port and RV port output | / |
| Press the USB Power Button | Turn on / off the USB output | / |
| Press the AC and DC Power Buttons simultaneously and hold for more than 2 seconds till the output frequency flashes | Enter / exit the Setting Mode | In the Setting Mode, the icons for the currently enabled functions remain lit, except for the flashing output frequency icon. If you do not perform any operation in 1 minute, the AC200Lwill automatically exit the Setting Mode, and no changes will be saved. |
| Press the DC Power Button in the Setting Mode | Navigate through the setting items | The flashing setting item is selected and editable. In the Setting Mode, the corresponding codes will be displayed on the left side: P01: Output Frequency P03: Charging Mode P04: Power Lifting Mode P05: ECO Mode P06: Bluetooth P07: WiFi |
| Press the AC Power Button when the setting item is flashing | Enable or disable the selected function. | / |
| Press and hold the DC Power Button in the Setting Mode | Switch the status page | You can view relevant information on the status page. Serial Number Error code Historical faults Version |
14. Troubleshooting
In the Setting Mode, press and hold the DC Power Button to switch the status page until the icon and the error code appear simultaneously on the screen. Please refer to the table below for helpful guidance.
| Error Code | Alarm Icon | Description | Troubleshooting |
| E001 | ALARM+1+AC | Inverter overload | Check if the power consumption of your devices is too high. Reduce the load if necessary. |
| E002 | AC+ALARM+ | Inverter overtemperature protection, AC output off | Wait for about 10 minutes until the unit cools down, then turn on the AC output again. |
| E003 | ALARM+1+AC | Inverter short circuit | 1. Check if the power consumption of your devices is too high. 2. Check if any of your electrical devices are causing a short circuit. |
| E033 | ALARM+1+AC | PV overvoltage | Make sure the PV input voltage is within the range of 12V to 145VDC. |
| E039 | ALARM+1+AC | PV overtemperature | Wait for about 10 minutes until the unit cools down, then re-enable the PV input. |
| E065 | DC+ALARM+ | DC output short circuit | 1. Check if the power consumption of your devices is too high. 2. Check if any of your electrical devices are causing a short circuit. |
| E067 | DC+ALARM+ | DC output overcurrent | Check if the power consumption of your devices is too high. Reduce the load if necessary. |
| E068 | DC+ALARM+ | DC output overtemperature | Wait for about 10 minutes until the unit cools down, then restart your devices. |
| E085 | +ALARM | Charging temperature too high | Wait for the unit to cool down before charging. |
| E086 | +ALARM | Charging temperature too low | Make sure the unit is placed in an ambient temperature of 0°C to 40°C (32°F to 104°F). |
| E087 | +ALARM | Discharging temperature too high | Wait for the unit to cool down before discharging. |
| E088 | + ALAAM | Discharging temperature too low | Make sure the unit is placed in an ambient temperature of -20°C to 40°C (-4°F to 104°F). |
| E115 | GRID | Grid overfrequency | Check if the grid frequency is too high. Contact your local power provider if necessary. |
| E116 | GRID | Grid underfrequency | Check if the grid frequency is too low. Contact your local power provider if necessary. |
| Others | / | / | Please contact BLUETTI support for assistance. |
When in Error Code page, press and hold the DC Power Button to switch the status page, when the appears, you can view the fault history. To clear the fault history, press and hold the AC Power Button for 2 seconds, and then release it.
Appx.1 Estimating Operation Time
To estimate the operation time of the AC200L, consider the load you're applying:
Operation time = Battery Capacity (Wh) × DoD × η ÷ (Load Power + AC200L Self-consumption)
Note: DoD refers to the depth of discharge. AC200L works at 95% DoD for longer battery life.
is the conversion efficiency of the inverter, typically over 93% for AC200L.
The self-consumption of AC200L is approximately 12W.
E.g. If you have a 40W refrigerator, you can run it for about 34.7 hours.
Operation time = 2,048Wh × 95% × 93% ÷ (40W + 12W) ≈ 34.7 hours.
Please keep in mind that the estimated operation time provided is for reference
purposes and may vary based on actual usage conditions. Factors such as low
temperature and excessive loads can significantly affect the battery capacity, leading to
a reduction in the average operation time.
Appx.2 FAQ
Q1: How do I know whether my devices will work well with this product?
A: Please evaluate the total constant load of your devices. If it doesn't exceed the Max. output power of AC200L (2,400W), you can use this power station to run your devices.
Note: Some devices with built-in motors or compressors may start at 2-4 times the rated power, which can easily overload the AC200L.
Q2: Can I use third-party solar panels to charge this product?
A: Yes, you can. However, make sure your solar panels have an open circuit voltage of 12V-145V and are equipped with MC4 connectors. It's also important not to mix different types of solar panels.
Q3: Can it charge and discharge at the same time?
A: Yes. It supports pass-through charging. The AC200L comes with the premium LiFePO _4 battery and proprietary Battery Management System to ensure that it can charge and discharge at the same time.
Q4: Why is the charging power often too low?
A: AC200L has a built-in intelligent BMS that automatically adjusts the charging power in response to the battery temperature and SoC, thus protecting the battery and extending its service life.
Appx.3 FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
IMPORTANT NOTE: FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.
Appx. 4 IC Caution
This device contains licence-exempt transmitter(s) / receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
RF exposure statement: The equipment complies with IC Radiation exposure limits set forth for uncontrolled environments. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
CANICES-3 (B)/NMB-3(B) (Canada)
This Class B digital apparatus complies with Canadian ICES-003.
For more information, please visit:
Web: https://www.bluettipower.com

@ BLUETTI Support
@ BLUETTI Official

@ bluetti_inc

@bluetti. inc

@bluetti_official

service@ bluettipower.com
SHENZHEN POWEROAK NEWENER CO., LTD.
Add: F19, BLD No.1, Kaidaer, Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China
USA Agent
Company: BLUETTI POWEROAK INC
Add: 6185 S VALLEY VIEW BLVD STE D LAS VEGAS
NEVADA 89118 United States
FRN: 0033559824
Customer Service
Tel: 800-200-2980 (Monday to Sunday 9:00-17:00)
Email: sale@bluettipower.com (Pre-sales),
service@bluettipower.com (After-sales)


BLUETTI


Certificate
Inspector:
QC:
EasyManual