ÉPIX Drive 900 - Professional audio equipment Chauvet Professional - Free user manual and instructions

Find the device manual for free ÉPIX Drive 900 Chauvet Professional in PDF.

Chauvet Professional ÉPIX Drive 900 - Professional audio equipment
📄 35 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Chauvet Professional ÉPIX Drive 900 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Type Professional LED driver and power supply for ÉPIX Tour products
Brand Chauvet Professional
Model ÉPIX Drive 900
Dimensions (L x W x H) 19 in x 7.6 in x 2 in (483 x 193 x 50 mm)
Weight 5.4 lb (2.5 kg)
Power Supply Type Switching (internal), auto-ranging 100-240 VAC, 50/60 Hz
Power Consumption 299 W
Current Draw 2.53 A @ 120 VAC, 1.44 A @ 208 VAC, 1.31 A @ 230 VAC
Max Load 900 LEDs; up to 18 ÉPIX Strip Tour, 6 ÉPIX Bar Tour, 36 ÉPIX Strip Tour 50, 6 ÉPIX Strip IP, or 12 ÉPIX Strip IP 50
Control Protocols Art-Net, sACN, Kling-Net
Control Personalities Pixel, 7-CH-Drive, 8-CH-fixture, 5-Section, 10-Section, 25-Section, 50-Section
Output Connector 4-pin XLR, 48 VDC
Maximum Cable Length Shielded: 65 ft to first product, 210 ft total; Unshielded: 150 ft to first product, 300 ft total
Fuse T 5 A, 250 V (replaceable)
Ingress Protection IP20 (indoor use only)
Maximum Ambient Temperature 113 °F (45 °C)
Cooling Fan-assisted convection
Included Accessories Neutrik powerCON power cord, rack ears (2) with screws, rubber feet (4), warranty card, quick reference guide
Maintenance Clean at least twice a month; use vacuum or dry compressed air, mild non-ammonia glass cleaner or isopropyl alcohol
Repairability No user-serviceable parts; fuse replacement available; firmware update via CHAUVET Professional Uploader

Frequently Asked Questions - ÉPIX Drive 900 Chauvet Professional

How many ÉPIX Tour products can the ÉPIX Drive 900 control?
The ÉPIX Drive 900 can control up to 900 LEDs in any combination. This translates to a maximum of 18 ÉPIX Strip Tour, 6 ÉPIX Bar Tour, 36 ÉPIX Strip Tour 50, 6 ÉPIX Strip IP, or 12 ÉPIX Strip IP 50 products. The exact number depends on the model and mix of products connected.
What control protocols does the ÉPIX Drive 900 support?
The ÉPIX Drive 900 supports Art-Net, sACN, and ArKaos Kling-Net for flexible control in touring, rental, and installation environments.
What is the maximum cable length between the Drive 900 and connected fixtures?
The maximum cable length from the Drive 900 to the first ÉPIX product is 65 ft (20 m) when using shielded cable, or 150 ft (45 m) when using unshielded cable. The total cable length through all daisy-chained products must not exceed 210 ft (64 m) shielded or 300 ft (91 m) unshielded.
How do I update the firmware on the ÉPIX Drive 900?
To update the firmware, download the CHAUVET Professional Uploader and the latest firmware file from the Chauvet website. Connect the ÉPIX Drive 900 to a PC via Ethernet, open the uploader, select the firmware file, and click Upload Firmware. If the device is not found, use the Force Upload mode by turning off the unit, holding the two specified buttons, and powering it back on.
What is the power consumption and what power input does it require?
The ÉPIX Drive 900 has an auto-ranging power supply that accepts 100–240 VAC, 50/60 Hz. It consumes 299 W, with current draw of 2.53 A at 120 V, 1.44 A at 208 V, and 1.31 A at 230 V. It also supports power linking of up to 6 units at 120 V, 11 at 208 V, and 12 at 230 V.
Can I mount the ÉPIX Drive 900 in a standard rack?
Yes, the ÉPIX Drive 900 is designed to fit in a standard 19-inch rack using the included removable rack ears. It can also be mounted with an M12 clamp or placed on a flat surface using its rubber feet.
What are the different control personalities available?
The Drive 900 offers 7 control personalities: Pixel (3 channels per LED), 7-CH-Drive, 8-CH-fixture, 5-Section, 10-Section, 25-Section, and 50-Section. These allow different levels of control from individual pixels to grouped sections.
How do I perform an auto address on connected fixtures?
To auto address connected fixtures, press the menu button until Auto Address appears, then press Enter. Select Yes and confirm. The Drive 900 will automatically detect and assign addresses to all connected ÉPIX products, regardless of their order or type.
What safety precautions should I follow when installing and operating the ÉPIX Drive 900?
Always connect the ÉPIX Drive 900 to a grounded circuit to avoid electrocution. Do not expose it to rain or moisture; it is IP20 rated for indoor use only. Mount it with at least 20 in (50 cm) of ventilation space, and use a safety cable when hanging. Never connect it to a dimmer pack or rheostat, and disconnect power before servicing.
How should I clean and maintain the ÉPIX Drive 900?
Clean the ÉPIX Drive 900 at least twice a month. Unplug the unit, let it cool to room temperature, use a vacuum or dry compressed air to remove dust from vents, and wipe surfaces with a soft cloth dampened with a mild non-ammonia glass cleaner or isopropyl alcohol. Avoid blowing compressed air into the cooling fans.

User questions about ÉPIX Drive 900 Chauvet Professional

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Professional audio equipment in PDF format for free! Find your manual ÉPIX Drive 900 - Chauvet Professional and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ÉPIX Drive 900 by Chauvet Professional.

USER MANUAL ÉPIX Drive 900 Chauvet Professional

ÉPIX

DRIVE 900

User Manual

Referencing Firmware V1.4.2

Chauvet Professional ÉPIX Drive 900 - User Manual - 1

Edition NotesThe ÉPIX Drive 900 User Manual Rev. 6 covers the description, safety precautions, installation, programming, operation, and maintenance of the ÉPIX Drive 900. Chauvet released this edition of the ÉPIX Drive 900 User Manual in 2020.
TrademarksCHAUVET, the Chauvet logo and ÉPIX Drive 900 are registered trademarks or trademarks of Chauvet & Sons Inc. (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
Copyright NoticeThe works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.© Copyright 2020 Chauvet & Sons, Inc. All rights reserved.Electronically published by Chauvet in the United States of America.
Manual UseChauvet authorizes its customers to download and print this manual for professional information purposes only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this manual or its content for any other purpose without written consent from Chauvet.
Document PrintingFor better results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4 paper (210 x 297 mm), configure your printer to scale the content accordingly.
Intended AudienceAny person in charge of installing, operating, and/or maintaining this product should completely read through the guide that shipped with the product, as well as this manual, before installing, operating, or maintaining this product.
DisclaimerChauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions.
Document RevisionThe ÉPIX Drive 900 User Manual Rev. 6 supersedes all previous versions of this manual. Discard any older versions of this manual and replace with this version. Go to www.chauvetprofessional.com for the latest version.

Table of Contents

1. Before You Begin....1

What Is Included....1

Claims .... 1

Manual Conventions .... 1

Symbols....1

Safety Notes....2

Personal Safety 2

Mounting And Rigging....2

Power And Wiring 2

Operation....2

Expected LED Lifespan....2

2. Introduction......3

Description ....3

Features ....3

Overview 3

Dimensions....4

3. Setup....5

AC Power 5

AC Plug 5

Power Linking....5

Fuse Replacement....5

Mounting....6

Orientation....6

Rigging 6

Procedure....6

Signal Connections 7

Art-Net™ Connection 7

sACN Connection....7

Kling-Net Connection 7

Connecting ÉPIX Products....8

Connection Diagram 12

4. Operation....13

Control Panel Description....13

Menu Map 13

Settings Configuration....14

Home Screen 14

Auto Addressing....14

View Linked Fixtures 14

LED Output Test 14

Protocol 14

Display Orientation....14

Factory Reset....14

Ethernet Settings....15

Control Values....16

Pixel Mode....16

7-CH-Drive Mode 17

8-CH-fixture Mode....18

5-Section Mode 19

10-Section Mode....19

25-Section Mode 20

50-Section Mode 21

  1. Firmware Update....25

Instructions 25

Force Upload Instructions 26

  1. Technical Information......27

Product Maintenance 27

  1. Technical Specifications ....28

Ordering 29

Returns 30

Contact Us....31

1. BEFORE YOU BEGIN

What Is Included

  • ÉPIX Drive 900
  • Neutrik® powerCON® power cord
  • Rack ears (2) w/ screws

  • Rubber feet (4)

  • Warranty Card
    • Quick Reference Guide

Claims

Carefully unpack the product immediately and check the box to make sure all the parts are in the package and are in good condition.

If the box or the contents (the product and included accessories) appear damaged from shipping or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.

For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Manual ConventionsConventionMeaning
1–512A range of values in the text
50/60A set of mutually exclusive values in the text
A button on the product's control panel
SettingsA product function or a menu option
MENU>SettingsA sequence of menu options
1–10A range of menu values from which to choose in a menu
Yes/NoA set of two mutually exclusive menu options in a menu
ONA unique value to be entered or selected in a menu

Symbols

SymbolsMeaning
Chauvet Professional ÉPIX Drive 900 - Symbols - 1Critical installation, configuration, or operation information. Failure to comply with this information may cause the product not to work, damage third-party equipment, or cause harm to the operator.
Chauvet Professional ÉPIX Drive 900 - Symbols - 2Important installation or configuration information. Failure to comply with this information may keep the product from working.
Chauvet Professional ÉPIX Drive 900 - Symbols - 3Useful information.

Chauvet Professional ÉPIX Drive 900 - Symbols - 4

The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol.

Safety Notes

Chauvet Professional ÉPIX Drive 900 - Safety Notes - 1

Chauvet Professional ÉPIX Drive 900 - Safety Notes - 2

Personal Safety

Mounting And Rigging

Power And Wiring

Operation

Read all the following Safety Notes before working with this product. These notes include important information about the installation, usage, and maintenance of this product.

This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained Chauvet certified technicians. Do not open the housing or attempt any repairs.

All applicable local codes and regulations apply to proper installation of this product.

  • Avoid direct eye exposure to the light source while the product is on.
    • Always disconnect this product from its power source before servicing.
    • Always connect this product to a grounded circuit to avoid the risk of electrocution.
  • Do not touch this product's housing during operation because it may be very hot.
  • This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. (IP20)
  • CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
  • Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
    • Make sure there are no flammable materials close to this product while it is operating.
  • When hanging this product, always secure to a fastening device using a safety cable.
  • Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product's specification label.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • Never connect this product to a dimmer pack or rheostat.
  • Never disconnect this product by pulling or tugging on the power cable.
  • Do not operate this product if you see damage on the housing, lenses, or cables. Have the damaged parts replaced by an authorized technician at once.
  • Do not cover the ventilation slots when operating to avoid internal overheating.
  • The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at a higher temperature.
    • In case of a serious operating problem, stop using this product immediately!

Chauvet Professional ÉPIX Drive 900 - All applicable local codes and regulations apply to proper installation of this product. - 1

Expected LED Lifespan

In the unlikely event that your Chauvet product requires service, contact Chauvet Technical Support.

LEDs gradually decline in brightness over time, due to heat. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal, single-LED conditions. For this reason, using clustered LEDs at their fullest intensity significantly reduces the LEDs' lifespan. Under normal conditions, this lifespan can be 40,000 to 50,000 hours. If extending this lifespan is vital, lower the operating temperature by improving the ventilation around the product and reducing the ambient temperature to an optimal operating range. In addition, limiting the overall projection intensity may help to extend the LEDs' lifespan.

2. INTRODUCTION

Description ÉPIX Drive 900 hosts the processing and power supply for the ÉPIX Tour product line in one convenient device. It controls up to 18 ÉPIX Strip Tour, 36 ÉPIX Strip Tour 50, 6 ÉPIX Bar Tour, 6 ÉPIX Strip IP, or 12 ÉPIX Strip IP 50 products easily using Art-Net™, sACN, or ArKaos Kling-Net. Configuration and setup are fast and easy with its built-in OLED display. Additionally, configuration can be managed with a network-based remote web server.

Features

  • The processing and power center of the ÉPIX Tour system will drive any combination of ÉPIX Tour products, up to 900 LEDs.
  • Versatile control options include Art-Net, Kling-Net, and sACN (streaming ACN) to support the touring/rental/installation markets.
  • Quickly and easily configure the ÉPIX Drive 900 using the built-in OLED display.
  • Easily detect and automatically configure your devices using the auto-address function, regardless of fixture order or type (bar/strip).
    • Supports up to 18 ÉPIX Strip Tours or 6 ÉPIX Bar Tours.
  • Easily daisy chain fixtures directly from the single output of the Drive 900 on a single cable.
  • Advanced power management design allows you to position the Drive 900 up to 65 ft away from your last fixture (using shielded cable).
  • Works with Arkaos Media Master Express for a plug-n-play system that requires almost no training to operate.

Overview
Chauvet Professional ÉPIX Drive 900 - Features - 1

Dimensions
Chauvet Professional ÉPIX Drive 900 - Features - 2

Chauvet Professional ÉPIX Drive 900 - Features - 3

3. SETUP

AC Power

Each ÉPIX Drive 900 has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each ÉPIX Drive 900, refer to the label affixed to the product. You can also refer to the Technical Specifications chart in this manual.

The listed current rating indicates the maximum current draw during normal operation. For more information, you may download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com.

Chauvet Professional ÉPIX Drive 900 - AC Power - 1

  • Always connect this product to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Chauvet Professional ÉPIX Drive 900 - AC Power - 2

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The ÉPIX Drive 900 comes with a power input cord terminated with a Neutrik® powerCON® A connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that came with your product has no plug, or if you need to change the Edison plug, use the table below to wire the new plug.

ConnectionWire (U.S.)Wire (Europe)Screw Color
AC LiveBlackBrownYellow or Brass
AC NeutralWhiteBlueSilver
AC GroundGreen/YellowGreen/YellowGreen

Power Linking

The ÉPIX Drive 900 supports power linking. You can power link up to 6 products at 120 V; up to 11 at 208 V; or up to 12 at 230 V.

This product comes with a power input cord. Power linking cables are available from Chauvet for purchase.

Fuse Replacement

  1. Disconnect this product from the power outlet.
  2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
  3. Remove the blown fuse and replace with another fuse of the same type and rating (T 5 A, 250 V).
  4. Screw the fuse holder cap back in place and reconnect power.

Chauvet Professional ÉPIX Drive 900 - Fuse Replacement - 1

Make sure to disconnect the product's power cord before replacing a blown fuse. Always replace the blown fuse with another of the same type and rating.

Mounting

Before mounting this product, read and follow the Safety Notes. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/.

Orientation

Always mount this product in a safe position and make sure there is adequate room for ventilation, configuration, and maintenance.

Rigging

Chauvet recommends using the following general guidelines when mounting this product.

  • When selecting an installation location, consider easy access to this product for operation, programming adjustments, and routine maintenance.
  • The product is not intended for permanent installation.
  • Make sure to mount this product away from any flammable material as indicated in the Safety Notes.
  • Never mount in places where rain, high humidity, extreme temperature changes, or restricted ventilation may affect the product.
  • Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
  • If hanging this product, make sure that the mounting location can support the product's weight. See the Technical Specifications for the weight-bearing requirements of this product.
  • When hanging this product, always secure to a fastening device using a safety cable. For our CHAUVET Professional line of safety cables, go to http://trusst.com/products/.
  • When mounting the product on the floor, make sure that the product and cables are away from people and vehicles.

Procedure

The ÉPIX Drive 900 fits nicely in a standard 19" rack using the included removable rack ears. You may also choose to attach a M12 mounting clamp for hanging or simply place it on its feet on a flat level surface. You must supply your own mounting hardware. Make sure all hardware and mounting surfaces are capable of supporting the weight of this product. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/.

Chauvet Professional ÉPIX Drive 900 - Procedure - 1

Surface Mounting

Mounting Diagram

Chauvet Professional ÉPIX Drive 900 - Mounting Diagram - 1

Chauvet Professional ÉPIX Drive 900 - Mounting Diagram - 2

Signal Connections

You can link the ÉPIX Drive 900 to controller software using an Ethernet connection. If using other Art-Net™, sACN or Kling-Net-compatible products with the ÉPIX Drive 900, you can control each individually on a single network.

Art-Net™ Connection

Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik® etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from www.chauvetprofessional.com. Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.

sACN Connection

Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture for Control Networks to transport DMX512 data over IP or any other ACN compatible network.

Kling-Net Connection

Kling-Net is a network protocol that allows auto configuration of display devices using a Neutrik® etherCON® RJ45 Ethernet connection. Refer to the ArKaos software manual for detailed instructions on programming this product. For smooth-running operation, ArKaos Kling-Net requires a gigabit (1000 Mbps) Ethernet card and network router.

Chauvet Professional ÉPIX Drive 900 - Kling-Net Connection - 1

Chauvet Professional ÉPIX Drive 900 - Kling-Net Connection - 2

Chauvet Professional ÉPIX Drive 900 - Kling-Net Connection - 3

Never connect an ÉPIX product to the WAN port of a router.

Connecting ÉPIX Products

The ÉPIX Drive 900 uses a 4-pin XLR connection to link all ÉPIX Tour and ÉPIX IP products. Each ÉPIX product must be daisy-chained together in series. Each ÉPIX Drive 900 can support up to 900 LEDs in 343 possible configurations that max out the capability of the product. The table below gives the maximum number of each product for the maximum given of each other product connected to one ÉPIX Drive 900.

Strip TourStrip Tour 50Bar Tour or Strip IPStrip IP 50Strip TourStrip Tour 50Bar Tour or Strip IPStrip IP 50
180004424
172004416
164004408
161014141
156004133
153014125
150104117
150024109
1480033000
1450132701
1421032410
1420232402
13100032111
1370132103
1341031820
1340231812
1311131804
1310331521
12120031513
1290131505
1261031230
1260231222
1231131214
1230331206
120203931
120123923
120043915
1114003907
1111013640
118103632
118023624
115113616
115033608
112203341
112123333
112043325
1016003317
1013013309
1010103050
1010023042
107113034
107033026
104203018
1041230010
1040423200
1012122901
1011322610
1010522602
9180022311
9150122303
9121022020
9120222012
991122004
990321721
962021713
961221705
960421430
932121422
931321414
930521406
903021131
902221123
901421115
900621107
820002840
817012832
814102824
814022816
811112808
811032541
88202533
88122525
88042517
85212509
85132250
85052242
82302234
82222226
82142218
820622010
7220013400
7190113101
7161012810
7160212802
7131112511
7130312503
7102012220
7101212212
7101412204
772111921
771311913
770511905
743011630
742211622
741411614
740611606
713111331
712311323
711511315
710711307
6240011040
6210111032
6181011024
6180211016
6151111008
615031741
612201733
612121725
612041717
69211709
69131450
69051442
66301434
66221426
66141418
660614010
63311151
63231143
63151135
63071127
60401119
603211011
602403600
601603301
600803010
5260003002
5230102711
5201002703
5200202420
5171102412
5170302404
5142002121
5141202113
5140402105
5112101830
5111301822
5110501814
583001806
582201531
581401523
580601515
553101507
552301240
551501232
550701224
524001216
523201208
52240941
52160933
52080925
428000917
425010909
422100650
422020642
419110634
419030626
416200618
4161206010
416040351
413210343
413130335
413050327
410300319
4102203011
410140060
410060052
47310044
47230036
47150028
470700110
444000012
4432

Chauvet Professional ÉPIX Drive 900 - Connecting ÉPIX Products - 1

In calculating the number of products which can be supported at once, ÉPIX Strip IP products are treated as having 150 LEDs, and ÉPIX Strip IP 50 products are treated as having 75 LEDs, due to differing power requirements for these products.

Connection Diagram

Length of cables between ÉPIX Drive 900 and 1 st product must not exceed 65 ft (20 m) when shielded, or 150 ft (45 m) when unshielded

Chauvet Professional ÉPIX Drive 900 - Connection Diagram - 1

Total length of cables cannot exceed 210 ft (64 m) when shielded, or 300 ft (91 m) when unshielded

4-pin XLR Cable Diagram (Indoor Cables)

Chauvet Professional ÉPIX Drive 900 - 4-pin XLR Cable Diagram (Indoor Cables) - 1

1 = Power + (16 AWG or larger)
2 = Data + (18–24 AWG)
3 = Data - (18-24 AWG)
4 = Power - (16 AWG or larger)

Chauvet Professional ÉPIX Drive 900 - 4-pin XLR Cable Diagram (Indoor Cables) - 2

  • The ÉPIX Drive 900 can support up to 18 ÉPIX Strip Tour products, 6 ÉPIX Bar Tour products, 36 ÉPIX Strip Tour 50 products, 6 ÉPIX Strip IP products, or 12 ÉPIX Strip IP 50 products, or any combination up to 900 LEDs.
  • In calculating the number of products which can be supported at once, ÉPIX Strip IP products are treated as having 150 LEDs, and ÉPIX Strip IP 50 products are treated as having 75 LEDs, due to differing power requirements for these products.
  • Make sure the total length of the connecting shielded 4-pin XLR cables does not exceed 210 feet (64 meters). Using unshielded cables will increase the maximum cable length to 300 feet (91 meters).

Chauvet Professional ÉPIX Drive 900 - 4-pin XLR Cable Diagram (Indoor Cables) - 3

  • Most standard 4-pin XLR "Scroller" cables are shielded.
    • IP rated cables are recommended when using ÉPIX IP products.

4. OPERATION

Control Panel DescriptionButtonFunction
Exits from the current menu or function or cycles through the main level of the menu
Navigates upward through the menu list or increases the numeric value when in a function
Navigates downward through the menu list or decreases the numeric value when in a function
Enables the currently displayed menu or sets the currently selected value into the current function

Menu Map

Firmware V1.4

Main LevelProgramming LevelsDescription
Auto AddressNoAutomatically find and address the products
Yes
View Linked Fixture1. X** - 36. X**Shows the connected products in order
LED OutputOffTurn off all LED output
RedRed LEDs at full
GreenGreen LEDs at full
BlueBlue LEDs at full
WhiteWhite LEDs at full
FadeColor roll fade at full
ScrollRainbow roll at full
ProtocolArt-NetSelects the Ethernet protocol and determines what other Menu options are available
Kling-Net
sACN
Display InverseNoTurn display 180 degrees
Yes
Factory ResetNoResets products to factory defaults
Yes
Ethernet SettingPersonalityPixelSets the control personality. See Control Personalities.
7-CH-Drive
8-CH-fixture
5-Section
10-Section
25-Section
50-Section
Universe000-246 (Art-NetTM)001-247 (sACN)Sets the lowest of the 6 consecutive Art-NetTM or sACN universes the product is assigned to
IP AddressIP Address #1*.x.x.x*1-126 (Art-NetTM)*1-255 (sACN)x = 0-255Sets the IP addresses for the ÉPIX Drive 900Note: The addresses cannot be the same
IP Address #2
IP Address #3
IP Address #4
IP Address #5
IP Address #6
DMX Address1-506Sets the DMX starting address

Chauvet Professional ÉPIX Drive 900 - OPERATION - 1
* - Each EPIX Drive 900 uses 6 consecutive universes that are assigned from the Universe level under Ethernet Setting.
** - The display will show the name of the connected product or nothing.

Settings Configuration

Home Screen

The ÉPIX Drive 900 has a home screen that displays the current protocol mode and IP addresses, or the Output Test mode. This screen shows at start-up, and after 15 seconds with no menu activity.

The home screen can also be viewed by pressing and holding

for 2 seconds.

Auto Addressing

The ÉPIX Drive 900 addresses connected products with the Auto Address function. To perform an Auto Address, do the following:

  1. Press repeatedly until Auto Address shows on the display.
  2. Press .
  3. Use or to select Yes.
  4. Press .

Chauvet Professional ÉPIX Drive 900 - Auto Addressing - 1

Perform an Auto Address every time products are connected, disconnected, or reconfigured, as soon as all changes have been made.

Chauvet Professional ÉPIX Drive 900 - Auto Addressing - 2

• Each LED or LED Section in each ÉPIX product requires 3 control channels.
- When multiple types of ÉPIX products are used, products will be addressed in order of connection.

View Linked Fixtures

To view all of the fixtures discovered by the Auto Addressing function, follow the instructions below:

  1. Press repeatedly until View Linked Fixture shows on the display.
  2. Press .
  3. Use or to scroll through the list of discovered products, 1–36.

LED Output Test

Output Test mode allows the user to test each output of the ÉPIX Drive 900, as well as the functionality of their ÉPIX Tour products. To run an output test:

  1. Press repeatedly until LED Output shows on the display.
  2. Press . The current test mode will begin to output.
  3. Use and to select one of seven output test modes: Red, Green, Blue, White, Fade, Scroll, or Off.
  4. Press .

Chauvet Professional ÉPIX Drive 900 - LED Output Test - 1

The ÉPIX Drive 900 will remain in Output Test mode until it receives a signal from a controller. To stop the color output without sending a signal to the product, set the LED Output to Off.

Protocol

The ÉPIX Drive 900 operates by routing one of three Ethernet protocols (Art-Net™, sACN, or Kling-Net) to the ÉPIX Tour products linked to the output of the Drive. The Ethernet protocol must be set for the products to respond correctly to the controller.

To configure the protocol for the ÉPIX Drive 900, follow the instructions below:

  1. Press repeatedly until Protocol shows on the display.
  2. Press
  3. Use or to select Art-Net, Kling-Net, or sACN.
  4. Press .

Display Orientation

To re-orient the display for easier reading in different mounting applications, do the following:

  1. Press repeatedly until Display Inverse shows on the display.
  2. Press .
  3. Use or to select Yes (for inverted) or No (for normal).
    Press .

Factory Reset

To reset the product to factory defaults:

  1. Press repeatedly until Factory Reset shows on the display.
  2. Press .
  3. Use or to select Yes.
    Press .

Chauvet Professional ÉPIX Drive 900 - Factory Reset - 1

After a Factory Reset, the ÉPIX Drive 900 will be set to Art-Net™ mode.

Ethernet Settings

To access the Ethernet Setting menu and configure the product for control by ethernet:

  1. Press repeatedly until Ethernet Setting shows on the display.
  2. Press .

Control Personalities

The ÉPIX Drive 900 uses Art-Net™ or sACN for its 7 control personalities:

PersonalityChannelsDescription
Pixel3 per LED(150 per ÉPIX Strip Tour)(450 per ÉPIX Bar Tour)Complete pixel control
7-CH-Drive7Dimmer, auto programs, and strobe
8-CH-fixture8 per ÉPIX productDimmer, auto programs, strobe, and dimmer speed
5-Section15 per ÉPIX productControls LED output in 5 sections of LEDs
10-Section30 per ÉPIX productControls LED output in 10 sections of LEDs
25-Section75 per ÉPIX productControls LED output in 25 sections of LEDs
50-Section150 per ÉPIX productControls LED output in 50 sections of LEDs

To select the control personality:

  1. Access the Ethernet Setting menu.
  2. Use or to select Personality.
  3. Press .
  4. Use or to select the desired personality, from Pixel, 7-CH-Drive, 8-CH-fixture, 5-Section, 10-Section, 25-Section, or 50-Section.
  5. Press .

Start Universe

Each ÉPIX Drive 900 uses 6 consecutive universes in Art-Net™ mode and sACN mode, which are assigned by setting the starting (lowest-numbered) universe address.

To set the address of the starting universe, do the following:

  1. Access the Ethernet Setting menu.
  2. Use or to select Universe.
  3. Use or to increase or decrease the universe address, from 0–246 (for ArtNet™), or 1–247 (for sACN).
  4. Press .

Chauvet Professional ÉPIX Drive 900 - Start Universe - 1

Each universe can support up to 3 ÉPIX Strip Tour products, 6 ÉPIX Strip Tour 50 products, 1 ÉPIX Bar Tour, 1 ÉPIX Strip IP, or 2 ÉPIX Strip IP 50 products. Regardless of the order in which they are connected, ÉPIX Strip Tour products will be grouped together, 3 to a universe.

IP Addresses

In Art-Net™ and sACN mode, the ÉPIX Drive 900 dedicates a separate IP address for each universe. To set any of the 6 IP addresses in the ÉPIX Drive 900, follow the instructions below:

  1. Access the Ethernet Setting menu.
  2. Use or to select IP Address.
  3. Press .
  4. Use or to select which IP address to configure, from IP Address #1-6.
  5. Press .
  6. Use or to set the highlighted number.
  7. Press .
  8. Repeat steps 3-4 until the IP address is set as desired.

Chauvet Professional ÉPIX Drive 900 - IP Addresses - 1

  • The beginnings of the IP addresses can be set from 1–126 in Art-Net mode, or from 1–255 in sACN mode. The beginnings of each IP address will always match.
    • The IP addresses cannot be identical.

DMX Address

To set the starting DMX address for the ÉPIX Drive 900:

  1. Access the Ethernet Setting menu.
  2. Use or to select DMX Address.
  3. Press .
  4. Use or to increase or decrease the DMX address, from 1–506.
  5. Press .

Control Values

Pixel ModeChannelFunctionValuePercent/Setting
1Red 1000 ⇔ 2550-100%
2Green 1000 ⇔ 2550-100%
3Blue 1000 ⇔ 2550-100%
4Red 2000 ⇔ 2550-100%
5Green 2000 ⇔ 2550-100%
6Blue 2000 ⇔ 2550-100%
7Red 3000 ⇔ 2550-100%
8Green 3000 ⇔ 2550-100%
9Blue 3000 ⇔ 2550-100%
10Red 4000 ⇔ 2550-100%
11Green 4000 ⇔ 2550-100%
12Blue 4000 ⇔ 2550-100%
13Red 5000 ⇔ 2550-100%
14Green 5000 ⇔ 2550-100%
15Blue 5000 ⇔ 2550-100%
16Red 6000 ⇔ 2550-100%
17Green 6000 ⇔ 2550-100%
18Blue 6000 ⇔ 2550-100%
19Red 7000 ⇔ 2550-100%
20Green 7000 ⇔ 2550-100%
21Blue 7000 ⇔ 2550-100%
22Red 8000 ⇔ 2550-100%
23Green 8000 ⇔ 2550-100%
24Blue 8000 ⇔ 2550-100%
25Red 9000 ⇔ 2550-100%
26Green 9000 ⇔ 2550-100%
27Blue 9000 ⇔ 2550-100%
28Red 10000 ⇔ 2550-100%
29Green 10000 ⇔ 2550-100%
30Blue 10000 ⇔ 2550-100%
............
436Red 146000 ⇔ 2550-100%
437Green 146000 ⇔ 2550-100%
438Blue 146000 ⇔ 2550-100%
439Red 147000 ⇔ 2550-100%
440Green 147000 ⇔ 2550-100%
441Blue 147000 ⇔ 2550-100%
442Red 148000 ⇔ 2550-100%
443Green 148000 ⇔ 2550-100%
444Blue 148000 ⇔ 2550-100%
445Red 149000 ⇔ 2550-100%
446Green 149000 ⇔ 2550-100%
447Blue 149000 ⇔ 2550-100%
448Red 150000 ⇔ 2550-100%
449Green 150000 ⇔ 2550-100%
450Blue 150000 ⇔ 2550-100%
7-CH-Drive ModeChannelFunctionValuePercent/Setting
1Dimmer000 ⇔ 2550–100%
2Red000 ⇔ 2550–100%
3Green000 ⇔ 2550–100%
4Blue000 ⇔ 2550–100%
5Auto Programs000 ⇔ 010No function
011 ⇔ 024Auto program 1
025 ⇔ 038Auto program 2
039 ⇔ 051Auto program 3
052 ⇔ 065Auto program 4
066 ⇔ 078Auto program 5
079 ⇔ 092Auto program 6
093 ⇔ 105Auto program 7
106 ⇔ 119Auto program 8
120 ⇔ 133Auto program 9
134 ⇔ 146Auto program 10
147 ⇔ 160Auto program 11
161 ⇔ 173Auto program 12
174 ⇔ 187Auto program 13
188 ⇔ 200Auto program 14
201 ⇔ 214Auto program 15
215 ⇔ 227Auto program 16
228 ⇔ 241Auto program 17
242 ⇔ 255All programs (Auto programs 1–17)
6Speed000 ⇔ 2550–100%
7Strobe000 ⇔ 010No function
011 ⇔ 255Strobe, slow to fast
8-CH-fixture ModeChannelFunctionValuePercent/Setting
1Dimmer000 ⇔ 2550–100%
2Red000 ⇔ 2550–100%
3Green000 ⇔ 2550–100%
4Blue000 ⇔ 2550–100%
5Auto Programs000 ⇔ 010No function
011 ⇔ 024Auto program 1
025 ⇔ 038Auto program 2
039 ⇔ 051Auto program 3
052 ⇔ 065Auto program 4
066 ⇔ 078Auto program 5
079 ⇔ 092Auto program 6
093 ⇔ 105Auto program 7
106 ⇔ 119Auto program 8
120 ⇔ 133Auto program 9
134 ⇔ 146Auto program 10
147 ⇔ 160Auto program 11
161 ⇔ 173Auto program 12
174 ⇔ 187Auto program 13
188 ⇔ 200Auto program 14
201 ⇔ 214Auto program 15
215 ⇔ 227Auto program 16
228 ⇔ 241Auto program 17
242 ⇔ 255All programs (Auto programs 1–17)
6Speed000 ⇔ 2550–100%
7Strobe000 ⇔ 010No function
011 ⇔ 255Strobe, slow to fast
8Dimmer Speed Mode000 ⇔ 101Linear dimmer
102 ⇔ 152Fast dimmer
153 ⇔ 203Medium dimmer
204 ⇔ 255Slow dimmer

5-Section Mode
(15 channels per ÉPIX product)

ChannelFunctionValuePercent/Setting
1Red 1000 ⇔ 2550–100%Section 1
2Green 1000 ⇔ 2550–100%
3Blue 1000 ⇔ 2550–100%
4Red 2000 ⇔ 2550–100%Section 2
5Green 2000 ⇔ 2550–100%
6Blue 2000 ⇔ 2550–100%
7Red 3000 ⇔ 2550–100%Section 3
8Green 3000 ⇔ 2550–100%
9Blue 3000 ⇔ 2550–100%
10Red 4000 ⇔ 2550–100%Section 4
11Green 4000 ⇔ 2550–100%
12Blue 4000 ⇔ 2550–100%
13Red 5000 ⇔ 2550–100%Section 5
14Green 5000 ⇔ 2550–100%
15Blue 5000 ⇔ 2550–100%

10-Section Mode
(30 channels per ÉPIX product)

ChannelFunctionValuePercent/Setting
1Red 1000 ⇔ 2550–100%Section 1
2Green 1000 ⇔ 2550–100%
3Blue 1000 ⇔ 2550–100%
4Red 2000 ⇔ 2550–100%Section 2
5Green 2000 ⇔ 2550–100%
6Blue 2000 ⇔ 2550–100%
7Red 3000 ⇔ 2550–100%Section 3
8Green 3000 ⇔ 2550–100%
9Blue 3000 ⇔ 2550–100%
10Red 4000 ⇔ 2550–100%Section 4
11Green 4000 ⇔ 2550–100%
12Blue 4000 ⇔ 2550–100%
13Red 5000 ⇔ 2550–100%Section 5
14Green 5000 ⇔ 2550–100%
15Blue 5000 ⇔ 2550–100%
16Red 6000 ⇔ 2550–100%Section 6
17Green 6000 ⇔ 2550–100%
18Blue 6000 ⇔ 2550–100%
19Red 7000 ⇔ 2550–100%Section 7
20Green 7000 ⇔ 2550–100%
21Blue 7000 ⇔ 2550–100%
22Red 8000 ⇔ 2550–100%Section 8
23Green 8000 ⇔ 2550–100%
24Blue 8000 ⇔ 2550–100%
25Red 9000 ⇔ 2550–100%Section 9
26Green 9000 ⇔ 2550–100%
27Blue 9000 ⇔ 2550–100%
28Red 10000 ⇔ 2550–100%Section 10
29Green 10000 ⇔ 2550–100%
30Blue 10000 ⇔ 2550–100%

25-Section Mode
(75 channels per ÉPIX product)

ChannelFunctionValuePercent/Setting
1Red 1000 ⇔ 2550–100%Section 1
2Green 1000 ⇔ 2550–100%
3Blue 1000 ⇔ 2550–100%
4Red 2000 ⇔ 2550–100%Section 2
5Green 2000 ⇔ 2550–100%
6Blue 2000 ⇔ 2550–100%
7Red 3000 ⇔ 2550–100%Section 3
8Green 3000 ⇔ 2550–100%
9Blue 3000 ⇔ 2550–100%
10Red 4000 ⇔ 2550–100%Section 4
11Green 4000 ⇔ 2550–100%
12Blue 4000 ⇔ 2550–100%
13Red 5000 ⇔ 2550–100%Section 5
14Green 5000 ⇔ 2550–100%
15Blue 5000 ⇔ 2550–100%
16Red 6000 ⇔ 2550–100%Section 6
17Green 6000 ⇔ 2550–100%
18Blue 6000 ⇔ 2550–100%
19Red 7000 ⇔ 2550–100%Section 7
20Green 7000 ⇔ 2550–100%
21Blue 7000 ⇔ 2550–100%
22Red 8000 ⇔ 2550–100%Section 8
23Green 8000 ⇔ 2550–100%
24Blue 8000 ⇔ 2550–100%
25Red 9000 ⇔ 2550–100%Section 9
26Green 9000 ⇔ 2550–100%
27Blue 9000 ⇔ 2550–100%
28Red 10000 ⇔ 2550–100%Section 10
29Green 10000 ⇔ 2550–100%
30Blue 10000 ⇔ 2550–100%
31Red 11000 ⇔ 2550–100%Section 11
32Green 11000 ⇔ 2550–100%
33Blue 11000 ⇔ 2550–100%
34Red 12000 ⇔ 2550–100%Section 12
35Green 12000 ⇔ 2550–100%
36Blue 12000 ⇔ 2550–100%
37Red 13000 ⇔ 2550–100%Section 13
38Green 13000 ⇔ 2550–100%
39Blue 13000 ⇔ 2550–100%
40Red 14000 ⇔ 2550–100%Section 14
41Green 14000 ⇔ 2550–100%
42Blue 14000 ⇔ 2550–100%
43Red 15000 ⇔ 2550–100%Section 15
44Green 15000 ⇔ 2550–100%
45Blue 15000 ⇔ 2550–100%
46Red 16000 ⇔ 2550–100%Section 16
47Green 16000 ⇔ 2550–100%
48Blue 16000 ⇔ 2550–100%
49Red 17000 ⇔ 2550–100%Section
50Green 17000 ⇔ 2550–100%
51Blue 17000 ⇔ 2550–100%
52Red 18000 ⇔ 2550–100%Section
53Green 18000 ⇔ 2550–100%
54Blue 18000 ⇔ 2550–100%
55Red 19000 ⇔ 2550–100%Section
56Green 19000 ⇔ 2550–100%
57Blue 19000 ⇔ 2550–100%
58Red 20000 ⇔ 2550–100%Section
59Green 20000 ⇔ 2550–100%
60Blue 20000 ⇔ 2550–100%
61Red 21000 ⇔ 2550–100%Section
62Green 21000 ⇔ 2550–100%
63Blue 21000 ⇔ 2550–100%
64Red 22000 ⇔ 2550–100%Section
65Green 22000 ⇔ 2550–100%
66Blue 22000 ⇔ 2550–100%
67Red 23000 ⇔ 2550–100%Section
68Green 23000 ⇔ 2550–100%
69Blue 23000 ⇔ 2550–100%
70Red 24000 ⇔ 2550–100%Section
71Green 24000 ⇔ 2550–100%
72Blue 24000 ⇔ 2550–100%
73Red 25000 ⇔ 2550–100%Section
74Green 25000 ⇔ 2550–100%
75Blue 25000 ⇔ 2550–100%

50-Section Mode (150 channels per ÉPIX product)

ChannelFunctionValuePercent/Setting
1Red 1000 ⇔ 2550–100%Section 1
2Green 1000 ⇔ 2550–100%
3Blue 1000 ⇔ 2550–100%
4Red 2000 ⇔ 2550–100%Section 2
5Green 2000 ⇔ 2550–100%
6Blue 2000 ⇔ 2550–100%
7Red 3000 ⇔ 2550–100%Section 3
8Green 3000 ⇔ 2550–100%
9Blue 3000 ⇔ 2550–100%
10Red 4000 ⇔ 2550–100%Section 4
11Green 4000 ⇔ 2550–100%
12Blue 4000 ⇔ 2550–100%
13Red 5000 ⇔ 2550–100%Section 5
14Green 5000 ⇔ 2550–100%
15Blue 5000 ⇔ 2550–100%
16Red 6000 ⇔ 2550–100%Section 6
17Green 6000 ⇔ 2550–100%
18Blue 6000 ⇔ 2550–100%
19Red 7000 ⇔ 2550–100%Section 7
20Green 7000 ⇔ 2550–100%
21Blue 7000 ⇔ 2550–100%
22Red 8000 ⇔ 2550–100%Section 8
23Green 8000 ⇔ 2550–100%
24Blue 8000 ⇔ 2550–100%
25Red 9000 ⇔ 2550–100%Section 9
26Green 9000 ⇔ 2550–100%
27Blue 9000 ⇔ 2550–100%
28Red 10000 ⇔ 2550–100%Section 10
29Green 10000 ⇔ 2550–100%
30Blue 10000 ⇔ 2550–100%
31Red 11000 ⇔ 2550–100%Section 11
32Green 11000 ⇔ 2550–100%
33Blue 11000 ⇔ 2550–100%
34Red 12000 ⇔ 2550–100%Section 12
35Green 12000 ⇔ 2550–100%
36Blue 12000 ⇔ 2550–100%
37Red 13000 ⇔ 2550–100%Section 13
38Green 13000 ⇔ 2550–100%
39Blue 13000 ⇔ 2550–100%
40Red 14000 ⇔ 2550–100%Section 14
41Green 14000 ⇔ 2550–100%
42Blue 14000 ⇔ 2550–100%
43Red 15000 ⇔ 2550–100%Section 15
44Green 15000 ⇔ 2550–100%
45Blue 15000 ⇔ 2550–100%
46Red 16000 ⇔ 2550–100%Section 16
47Green 16000 ⇔ 2550–100%
48Blue 16000 ⇔ 2550–100%
49Red 17000 ⇔ 2550–100%Section 17
50Green 17000 ⇔ 2550–100%
51Blue 17000 ⇔ 2550–100%
52Red 18000 ⇔ 2550–100%Section 18
53Green 18000 ⇔ 2550–100%
54Blue 18000 ⇔ 2550–100%
55Red 19000 ⇔ 2550–100%Section 19
56Green 19000 ⇔ 2550–100%
57Blue 19000 ⇔ 2550–100%
58Red 20000 ⇔ 2550–100%Section 20
59Green 20000 ⇔ 2550–100%
60Blue 20000 ⇔ 2550–100%
61Red 21000 ⇔ 2550–100%Section 21
62Green 21000 ⇔ 2550–100%
63Blue 21000 ⇔ 2550–100%
64Red 22000 ⇔ 2550–100%Section 22
65Green 22000 ⇔ 2550–100%
66Blue 22000 ⇔ 2550–100%
67Red 23000 ⇔ 2550–100%Section 23
68Green 23000 ⇔ 2550–100%
69Blue 23000 ⇔ 2550–100%
70Red 24000 ⇔ 2550-100%Section 24
71Green 24000 ⇔ 2550-100%
72Blue 24000 ⇔ 2550-100%
73Red 25000 ⇔ 2550-100%Section 25
74Green 25000 ⇔ 2550-100%
75Blue 25000 ⇔ 2550-100%
76Red 26000 ⇔ 2550-100%Section 26
77Green 26000 ⇔ 2550-100%
78Blue 26000 ⇔ 2550-100%
79Red 27000 ⇔ 2550-100%Section 27
80Green 27000 ⇔ 2550-100%
81Blue 27000 ⇔ 2550-100%
82Red 28000 ⇔ 2550-100%Section 28
83Green 28000 ⇔ 2550-100%
84Blue 28000 ⇔ 2550-100%
85Red 29000 ⇔ 2550-100%Section 29
86Green 29000 ⇔ 2550-100%
87Blue 29000 ⇔ 2550-100%
88Red 30000 ⇔ 2550-100%Section 30
89Green 30000 ⇔ 2550-100%
90Blue 30000 ⇔ 2550-100%
91Red 31000 ⇔ 2550-100%Section 31
92Green 31000 ⇔ 2550-100%
93Blue 31000 ⇔ 2550-100%
94Red 32000 ⇔ 2550-100%Section 32
95Green 32000 ⇔ 2550-100%
96Blue 32000 ⇔ 2550-100%
97Red 33000 ⇔ 2550-100%Section 33
98Green 33000 ⇔ 2550-100%
99Blue 33000 ⇔ 2550-100%
100Red 34000 ⇔ 2550-100%Section 34
101Green 34000 ⇔ 2550-100%
102Blue 34000 ⇔ 2550-100%
103Red 35000 ⇔ 2550-100%Section 35
104Green 35000 ⇔ 2550-100%
105Blue 35000 ⇔ 2550-100%
106Red 36000 ⇔ 2550-100%Section 36
107Green 36000 ⇔ 2550-100%
108Blue 36000 ⇔ 2550-100%
109Red 37000 ⇔ 2550-100%Section 37
110Green 37000 ⇔ 2550-100%
111Blue 37000 ⇔ 2550-100%
112Red 38000 ⇔ 2550-100%Section 38
113Green 38000 ⇔ 2550-100%
114Blue 38000 ⇔ 2550-100%
115Red 39000 ⇔ 2550-100%Section 39
116Green 39000 ⇔ 2550-100%
117Blue 39000 ⇔ 2550-100%
118Red 40000 ⇔ 2550–100%Section 40
119Green 40000 ⇔ 2550–100%
120Blue 40000 ⇔ 2550–100%
121Red 41000 ⇔ 2550–100%Section 41
122Green 41000 ⇔ 2550–100%
123Blue 41000 ⇔ 2550–100%
124Red 42000 ⇔ 2550–100%Section 42
125Green 42000 ⇔ 2550–100%
126Blue 42000 ⇔ 2550–100%
127Red 43000 ⇔ 2550–100%Section 43
128Green 43000 ⇔ 2550–100%
129Blue 43000 ⇔ 2550–100%
130Red 44000 ⇔ 2550–100%Section 44
131Green 44000 ⇔ 2550–100%
132Blue 44000 ⇔ 2550–100%
133Red 45000 ⇔ 2550–100%Section 45
134Green 45000 ⇔ 2550–100%
135Blue 45000 ⇔ 2550–100%
136Red 46000 ⇔ 2550–100%Section 46
137Green 46000 ⇔ 2550–100%
138Blue 46000 ⇔ 2550–100%
139Red 47000 ⇔ 2550–100%Section 47
140Green 47000 ⇔ 2550–100%
141Blue 47000 ⇔ 2550–100%
142Red 48000 ⇔ 2550–100%Section 48
143Green 48000 ⇔ 2550–100%
144Blue 48000 ⇔ 2550–100%
145Red 49000 ⇔ 2550–100%Section 49
146Green 49000 ⇔ 2550–100%
147Blue 49000 ⇔ 2550–100%
148Red 50000 ⇔ 2550–100%Section 50
149Green 50000 ⇔ 2550–100%
150Blue 50000 ⇔ 2550–100%

5. FIRMWARE UPDATE

On occasion, updates to the firmware for the ÉPIX Drive 900 are available. The following is the procedure for obtaining and installing these updates on a Windows PC.

Instructions

  1. Download the CHAUVET Professional Uploader from http://www.chauvetprofessional.com/products/epix-drive-900 and install it.
  2. Download the latest firmware update from http://www.chauvetprofessional.com/products/epix-drive-900.

  3. After downloading the software and update file, disable or disconnect any networks the PC is connected to. Do NOT disable the network created when the ÉPIX Drive 900 is connected in the next step.

  4. Power on the ÉPIX Drive 900 and connect it to the computer using an ethernet cable.
  5. Open the ÉPIX Drive 900 upload software.
  6. Use the Browse option to select the latest firmware update to upload.
  7. Click Next.
  8. Click Find Compatible Devices.
  9. Click Next when the software indicates a device has been found.
  10. If the software cannot find the ÉPIX Drive 900 on the network, see Force Upload Instructions.

  11. Select the checkbox next to Epix Tour 900.

  12. Click Upload Firmware.

  13. Wait for the upload to complete. Do NOT disconnect or power off the product during this process.
  14. When the status field says Done, exit out of the upload software.
  15. Disconnect the ÉPIX Drive 900 from the computer. The firmware update is complete.

Chauvet Professional ÉPIX Drive 900 - Instructions - 1

Chauvet Professional ÉPIX Drive 900 - Instructions - 2

Chauvet Professional ÉPIX Drive 900 - Instructions - 3

Force Upload Instructions

In the event that the upload software cannot find the ÉPIX Drive 900 on the network, follow the instructions below:

  1. Turn off the ÉPIX Drive 900. Press and hold and , then turn it back on. The display menu will flash, indicating the product is in Force Upload mode.
  2. After selecting the firmware update file and continuing to the Find Compatible Devices page, check off the Force Upload option.
  3. Click Next.

Chauvet Professional ÉPIX Drive 900 - Force Upload Instructions - 1

  1. Click Upload Firmware.
  2. Wait for the upload to complete. Do NOT disconnect or power off the product during this process.
  3. When the upload is complete, exit out of the upload software.
  4. Disconnect the ÉPIX Drive 900 from the computer. The firmware update is complete.

Chauvet Professional ÉPIX Drive 900 - Force Upload Instructions - 2

6. TECHNICAL INFORMATION

Product Maintenance

To maintain optimum performance and minimize wear, you should clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency.

As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear.

To clean your product:

  1. Unplug the product from power.
  2. Wait until the product is at room temperature.
  3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external vents.
  4. Clean all external surfaces with a mild solution of non-ammonia glass cleaner or isopropyl alcohol.
  5. Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
  6. Wipe any dirt or grime to the outside edges of the lens surface.
  7. Gently polish the lens surfaces until they are free of haze and lint.

Chauvet Professional ÉPIX Drive 900 - Product Maintenance - 1

Always dry the external surfaces thoroughly and carefully after cleaning them.

Chauvet Professional ÉPIX Drive 900 - Product Maintenance - 2

Do not spin the cooling fans by blowing compressed air into them.

  1. TECHNICAL SPECIFICATIONS
Dimensions and WeightLengthWidthHeightWeight
19 in (483 mm)7.6 in (193 mm)2 in (50 mm)5.4 lb (2.5 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
PowerPower Supply TypeRangeVoltage Selection
Switching (internal)100–240 VAC, 50/60 HzAuto-ranging
Parameter120 VAC, 60 Hz208 VAC, 60 Hz230 VAC, 50 Hz
Consumption299 W299 W299 W
Current2.53 A1.44 A1.31 A
Power linking current (products)13.6 A (6 products)13.6 A (11 products)13.6 A (12 products)
Fuse/BreakerT 5 A, 250 VT 5 A, 250 VT 5 A, 250 V
Power I/OU.S./CanadaWorldwide
Power input connectorNeutrik® powerCON® ANeutrik® powerCON® A
Power output connectorNeutrik® powerCON® BNeutrik® powerCON® B
Power cord plugEdison (U.S.)Local plug
ÉPIX Product OutputOutput ConnectorOutput Voltage
4-pin XLR48 VDC
ÉPIX ProductMaximum Load Per DriveLEDs Per Product
ÉPIX Strip Tour18 products50
ÉPIX Strip Tour 5036 products25
ÉPIX Bar Tour6 products150
ÉPIX Strip IP6 products100 (treated as 150)
ÉPIX Strip IP 5012 products50 (treated as 75)
any combination up to 900 LEDs
Maximum Cable LengthsShieldedUnshielded
From Drive to 1st ÉPIX product65 ft (20 m)150 ft (45 m)
Between ÉPIX products60 ft (18 m)100 ft (30 m)
Total from Drive through all ÉPIX products210 ft (64 m)300 ft (91 m)
Art-NetTM and sACNI/O ConnectorChannel Range(per ÉPIX product)Universes
Amphenol XLRnet7 (total), 8, 15, 30, 150 or 4506
ArKaos Kling-NetI/O ConnectorChannel Range
Amphenol XLRnetDetermined per ArKaos MediaMaster software
ThermalMax. External TemperatureCooling System
113 °F (45 °C)Fan-Assisted Convection

Ordering

Product NameItem NameItem CodeUPC Number
ÉPIX ProductsÉPIX Drive 900EPIXDRIVE90003091141781462214890
ÉPIX Strip TourEPIXSTRIPTOUR03091139781462214876
ÉPIX Strip Tour 50EPIXSTRIPTOUR5009031436781462217846
ÉPIX Bar TourEPIXBARTOUR03091140781462214883
ÉPIX Strip IPEPIXSTRIPTIP03091318781462216665
ÉPIX Strip IP 50EPIXSTRIPTIP5003091435781462217839
AccessoriesÉPIX Strip Tour Dome Accessory (4 pieces)EPIXSTRIPDOME03091142781462214906
4-pin XLR Cables4-pin XLR Extension Cable, 16 in4PINEXT16IN19111143781462214913
4-pin XLR Extension Cable, 5 ft4PINEXT5FT19111144781462214920
4-pin XLR Extension Cable, 50 ft4PINEXT50FT19111147781462214951
etherCON CablesNeutrik® etherCON® Extension Cable, 18 inETHERCONEXT18IN19090363781462207151
Neutrik® etherCON® Extension Cable, 5 ftETHERCONEXT5FT19090364781462207168
Neutrik® etherCON® Extension Cable, 10 ftETHERCONEXT10FT19090365781462207175
Neutrik® etherCON® Extension Cable, 25 ftETHERCONEXT25FT19090366781462207182
Neutrik® etherCON® Extension Cable, 50 ftETHERCONEXT50FT19090367781462207199
powerCON CablesNeutrik® powerCON® Extension Cable, 18 inPOWERCONEXT18IN19110372781462207243
Neutrik® powerCON® Extension Cable, 5 ftPOWERCONEXT5FT19110373781462207250
Neutrik® powerCON® Extension Cable, 10 ftPOWERCONEXT10FT19110374781462207267
Neutrik® powerCON® Extension Cable, 25 ftPOWERCONEXT25FT19110375781462207274
Neutrik® powerCON® Extension Cable, 50 ftPOWERCONEXT50FT19110376781462207281

For the most current list of related products and accessories available from CHAUVET Professional, visit our website at www.chauvetprofessional.com.

RETURNS

To get support or return a product:

• If you are located in the U.S., contact Chauvet World Headquarters.
• If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
• If you are located in Benelux, contact Chauvet Europe BVBA.
• If you are located in France, contact Chauvet France.
• If you are located in Germany, contact Chauvet Germany.
• If you are located in Mexico, contact Chauvet Mexico.

If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local distributor. See www.chauvetprofessional.com for distributors outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico.

Chauvet Professional ÉPIX Drive 900 - RETURNS - 1

If you are located outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico, contact your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetprofessional.com for contact details.

Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return.

To submit a service request online, go to www.chauvetprofessional.com/service-request.

Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags.

Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.

Chauvet Professional ÉPIX Drive 900 - RETURNS - 2

Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.

Before sending the product, clearly write the following information on a piece of paper and place it inside the box:

  • Your name
  • Your address
  • Your phone number
  • RMA number

• A brief description of the problem

Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.

Chauvet Professional ÉPIX Drive 900 - RETURNS - 3

Chauvet reserves the right to use its own discretion to repair or replace returned product(s).

CONTACT Us

General InformationTechnical Support
World Headquarters
Address: 5200 NW 108th AvenueSunrise, FL 33351Voice: (954) 577-4455Fax: (954) 929-5560Toll free: (800) 762-1084Voice: (844) 393-7575Fax: (954) 756-8015Email:chauvetcs@chauvetlighting.comWebsitewww.chauvetprofessional.com
UK
Address: Unit 1CBrookhill Road Industrial EstatePinxton, Nottingham, UKNG16 6NTVoice: +44 (0)1773 511115Fax: +44 (0)1773 511110Email:UKtech@chauvetlighting.euWebsite:www.chauvetprofessional.eu
Benelux
Address: Stokstraat 189770 KruishoutemBelgiumVoice: +32 9 388 93 97Email:BNLtech@chauvetlighting.euWebsite:www.chauvetprofessional.eu
France
Address: 3, Rue Ampère91380 Chilly-MazarinFranceVoice: +33 1 78 85 33 59Email:FRtech@chauvetlighting.frWebsite:www.chauvetprofessional.eu
Germany
Address: Bruno-Bürgel-Str. 1128759 BremenGermanyVoice: +49 421 62 60 20Email:DEtech@chauvetlighting.deWebsite:www.chauvetprofessional.eu
Mexico
Address: Av. de las Partidas 34-3B(Entrance by Calle 2)Zona Industrial LermaLerma, Mexico C.P. 52000Voice: +52 (728) 690-2010Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., United Kingdom, Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.Email:servicio@chauvet.com.mxWebsite:www.chauvetprofessional.mx
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Chauvet Professional

Model : ÉPIX Drive 900

Category : Professional audio equipment