TGPS 18-401-30 - Uncategorized GUDE - Free user manual and instructions

Find the device manual for free TGPS 18-401-30 GUDE in PDF.

GUDE TGPS 18-401-30 - Uncategorized
📄 108 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice GUDE TGPS 18-401-30 - page 38
Pick your language and provide your email: we'll send you a specifically translated version.
Product typeRemotely controllable power distribution unit (PDU)
BrandGUDE
ModelTGPS 18-401-30
Nominal voltage400 V three-phase
Frequency50/60 Hz
Maximum power12 kW
Maximum current32 A
Network interfacesEthernet 10/100/1000 Mbps
Network protocolsSNMP, HTTP/HTTPS, SSH, Modbus TCP
Measurement functionsCurrent, voltage, power, energy
Remote controlRelay switching for each outlet
DisplayIntegrated LCD screen
Mounting19-inch rack, 1U
Operating temperature0 °C to 50 °C
Relative humidity5 % to 95 % (without condensation)
MaintenanceClean with a dry cloth; no parts requiring periodic replacement
Safety standardsOverload protection, fuses, grounding
Included accessoriesEthernet cable, rack mounting kit, documentation
Dimensions (WxDxH)482.6 x 200 x 44.5 mm (estimated)
Weight2.8 kg (estimated)
RepairabilitySpare parts available from the manufacturer

Frequently Asked Questions - TGPS 18-401-30 GUDE

How to install the TGPS 18-401-30?
Before installation, cut off the main power supply. Mount the device to the rack using the mounting kit. Connect the network cables and electrical outlets following the diagrams in the manual. Power on and verify that the LCD screen displays the default parameters.
What is the required supply voltage?
The device operates on 400 V three-phase with a frequency of 50/60 Hz. The tolerance is ±10% on the voltage.
How to configure the IP address?
Use the local interface via the LCD screen or connect via HTTP with the default IP address (see manual). Access the Network menu to set a fixed IP address or use DHCP via the SNMP protocol.
How to monitor power consumption?
The TGPS 18-401-30 measures in real time current, voltage, power and energy. The data is accessible via the web interface or sent to a monitoring server via Modbus TCP or SNMP.
How to enable remote control?
In the web interface, go to the Outlets section and enable manual or scheduled mode. You can turn each outlet on/off remotely.
What to do if the device does not start?
Check the input voltage and the presence of fuses. Test the power cable and the outlet. If the screen remains off, contact technical support.
How to perform maintenance?
Clean the ventilation grilles regularly with a lint-free cloth. Periodically check the connections and the absence of overheating. No part requires preventive maintenance.
What are the safety protections?
The device has overload protection, fuses, and a grounding terminal. It complies with current electrical safety standards.
How to reset to factory settings?
Press and hold the Reset button on the rear for 10 seconds. The device restarts with default settings. Note that this erases all network configuration.
How to update the firmware?
Download the update file from the manufacturer's website. Log in to the web interface, System > Update section, then select the file. Do not cut off the power during the process.

User questions about TGPS 18-401-30 GUDE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual TGPS 18-401-30 - GUDE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TGPS 18-401-30 by GUDE.

USER MANUAL TGPS 18-401-30 GUDE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GUDE

Model : TGPS 18-401-30

Category : Uncategorized