| Product Type | Submersible Water Pump |
| Brand | Vevor |
| Model | KPD2110G |
| Pump Type | Centrifugal single-stage pump with vertical float switch |
| Max Flow Rate | 2500 GPH (approx. 9450 L/H) |
| Max Head | 33 ft (approx. 10 m) |
| Power Source | AC 110-120V, 60Hz |
| Rated Power | 745W (1 HP) |
| Discharge Size | 1.5 inch NPT (approx. 38 mm) |
| Impeller Type | Non-clogging vortex impeller |
| Housing Material | Cast iron with powder-coated finish |
| Power Cord Length | 16.4 ft (5 m) |
| Thermal Protection | Built-in auto reset thermal overload protector |
| Duty Cycle | Continuous operation with float switch control |
| Max Liquid Temperature | 95°F (35°C) |
| Minimum Sump Width | 18 inches (45.7 cm) |
| Dimensions (L x W x H) | 9.8 x 6.3 x 11.4 inches (25 x 16 x 29 cm) |
| Net Weight | 16.5 lbs (7.5 kg) |
| Installation | Vertical submersible installation in basin or sump |
| Sound Level | Approx. 68 dB at 3 ft |
| Maintenance and Cleaning | Remove debris from inlet screen and clean housing; inspect float switch regularly |
| Safety Protection | IPX8 waterproof rating, grounded plug, automatic shut-off if motor overheats |
| Spare Parts and Repairability | Replacement impeller, seals, float switch and capacitor available; service using standard tools |
| Included Items | Pump, user manual |
Frequently Asked Questions - KPD2110G Vevor
How do I install the KPD2110G pump?
Place the pump vertically on a firm, flat surface at the bottom of the basin. Connect the discharge pipe to the 1.5 inch outlet and tighten it by hand. Plug the power cord into a grounded 110-120V outlet and adjust the float switch so it activates before the water level rises too high.
What is the maximum flow rate and head?
The KPD2110G can deliver up to 2500 GPH at zero lift and can pump water up to a maximum head of about 33 feet. Actual performance depends on hose diameter and vertical distance.
Can the pump run dry?
No, running the pump without water can damage the mechanical seal and overheat the motor. The thermal protector will shut the motor off, but you should always submerge the pump before connecting power.
How do I clean the pump after use?
Disconnect the power and wipe the housing with a damp cloth. Remove any debris from the inlet screen and flush the impeller chamber with clean water. Never use solvents that can damage the seals.
Why is the pump not turning on?
Check the power supply, the grounded outlet, and the thermal overload protector which may have tripped. Also make sure the float switch is not stuck in the lower position. If the motor hums but does not start, the impeller may be blocked.
Can I use the pump for dirty water?
It is designed for clean or slightly cloudy water with solids up to 0.5 inches. It should not be used for sewage, chemicals, or flammable liquids. Use a gravel guard if pumping from an excavation.
What voltage and frequency does it need?
The pump requires a standard AC 110-120V, 60Hz grounded power supply. Do not use an extension cord longer than 50 feet, as voltage drop can reduce performance and damage the motor.
How do I protect the pump from freezing?
Before winter, disconnect the pump and drain all water from the outlet and impeller housing. Store it in a frost-free location. If it is installed outside, use heating tape on the discharge line to prevent ice blockage.
Is the pump repairable? Where can I find spare parts?
Yes, the pump is designed to be serviceable. Common spare parts include the impeller, seal kit, float switch, and capacitor. Contact Vevor customer service or check the spare parts list in the user manual for part numbers.
How does the float switch work?
The tethered float switch starts the pump when the water rises to the upper position and stops it when the water falls to the lower position. Keep the cord free so the float can move through its full arc without touching the pump body or basin wall.
User questions about KPD2110G Vevor
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Pumps in PDF format for free! Find your manual KPD2110G - Vevor and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KPD2110G by Vevor.