Product type Industrial power socket 30 A
Brand Vevor
Model STD01-030A
Power supply 220-240 V ~, 30 A, 50/60 Hz
Rated voltage 220-240 V ~
Rated current 30 A
Protection rating IP44
Number of poles 3P + N + T (three-phase neutral and earth)
Housing material Impact-resistant technical polyamide
Contact material Nickel-plated brass
Dimensions 105 × 105 × 70 mm
Weight 280 g
Operating temperature -25 °C to +50 °C
Permissible cable cross-section 2.5 to 10 mm²
Mounting type Wall mounting on electrical box
Applicable standards IEC 60309 / EN 60309
Main functions Secure connection of industrial equipment, mechanical locking of the connector
Maintenance and cleaning Disconnect before maintenance, clean with a dry cloth
Safety Mandatory earthing, installation by a qualified electrician
Spare parts and repairability Replaceable contacts and seals, repair by a professional
General information 140-page user manual including installation, use, and maintenance guide

Frequently Asked Questions - STD01-030A Vevor

What is the rating of the STD01-030A socket?
This socket supports a rated current of 30 A at a voltage of 220-240 V, frequency 50/60 Hz. Make sure your installation is protected by a suitable circuit breaker.
Is this socket compatible with a three-phase installation?
Yes, the STD01-030A model is designed for a three-phase 3P + N + T supply with neutral and earth. Never connect the socket to a single-phase installation without adapting the wiring.
What is the IP rating of the Vevor socket?
The IP rating is IP44: it is protected against solid objects larger than 1 mm and water splashes. It is therefore suitable for indoor and sheltered use.
How to install the STD01-030A socket?
First cut off the power, then connect the conductors to the screw terminals respecting the color code: phase, neutral and earth. Wall mounting is done using the 4 screws provided.
What cable cross-section should I use?
For a current of 30 A, it is recommended to use a cable with a cross-section of at least 6 mm². The socket terminals accept conductors up to 10 mm².
How to maintain the Vevor electrical socket?
Always disconnect the device before cleaning. Use a non-abrasive dry cloth and never spray water or liquid products inside the socket.
Can I replace damaged parts?
The contacts and seals are replaceable. For any repair, call a professional and use only original Vevor spare parts.
What is the maximum operating temperature?
This socket is designed to operate in a temperature range of -25 °C to +50 °C. Beyond this, the insulation of the materials may deteriorate.
Is earthing mandatory?
Yes, earthing is essential for this device. It protects the user in the event of an insulation fault. Never use the socket without the earth conductor.
Is the socket suitable for outdoor use?
With its IP44 rating, it can be installed in an outdoor environment protected from direct rain. Do not leave it exposed to prolonged humidity.

User questions about STD01-030A Vevor

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Socket in PDF format for free! Find your manual STD01-030A - Vevor and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. STD01-030A by Vevor.

USER MANUAL STD01-030A Vevor

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Vevor

Model : STD01-030A

Category : Socket