Product type Split type, wall-mounted indoor unit with outdoor condenser
Cooling capacity 7000 BTU/h (2.05 kW)
Heating type Reverse-cycle heat pump
Room coverage Up to 20 m² depending on insulation
Refrigerant R32
Power supply 220-240 V, 50 Hz
Indoor unit dimensions (W×H×D) 700 × 275 × 189 mm
Indoor unit weight 7.5 kg
Outdoor unit dimensions (W×H×D) 660 × 430 × 250 mm
Outdoor unit weight 21 kg
Operating modes Cooling, heating, fan, dehumidification, auto
Fan speeds 3 speeds plus automatic
Air filter Washable fine dust filter
Timer 24-hour programmable timer
Sleep mode Yes
Energy efficiency A++ cooling, A+ heating (typical)
Indoor noise level 23-38 dB(A)
Outdoor noise level About 50 dB(A)
Air flow direction Vertical and horizontal automatic swing
Operating temperature range Cooling +18 to +46 °C; heating -15 to +24 °C
Drain connection Condensate drain hose included
Refrigerant line max length Up to 15 m
Maintenance Clean filter every 2-3 weeks and keep coils free of dirt
Safety features Overheat protection, compressor delay, self-diagnostic function
Spare parts and repairability Remote control, filters, drain hose and mounting brackets available
General 2-year warranty, designed for household use

Frequently Asked Questions - ACP-07CH21AEMI/I Vivax

How do I clean the air filter on the Vivax ACP-07CH21AEMI/I?
Turn off the unit and unplug it. Open the front panel, slide out the filter, and wash it with warm water and mild detergent. Let it dry completely before putting it back. For best performance, clean the filter every two to three weeks.
What should I do if the air conditioner is not cooling properly?
Check that the set temperature is below room temperature, the filter is clean, and all doors and windows are closed. Make sure the outdoor unit is not blocked and the unit is in cooling mode with a suitable fan speed. If the problem continues, contact an authorized service technician.
Can the air conditioner be used in winter for heating?
Yes, this model includes a reverse-cycle heating function. Use the remote to select heat mode and set the desired temperature. At very low outdoor temperatures, heating performance may decrease and automatic defrosting may activate.
How does the timer function work?
The timer allows you to program the unit to switch on or off after a selected period, up to 24 hours. Press the timer button, set the desired time with the arrow keys, and confirm. You can program the unit to start cooling before you arrive home.
Why is water leaking from the indoor unit?
Check that the unit is mounted level and that the drain hose is not blocked or kinked. A dirty filter or frozen evaporator coil can also cause dripping. Clean the filter and inspect the drain hose regularly; if leakage persists, call a qualified installer.
Is professional installation required?
Yes, a split air conditioner must be installed by a certified technician. Installation includes connecting the refrigerant lines, electrical wiring, draining, and vacuuming the system. Incorrect installation can affect performance and safety.
How can I use the dehumidification mode?
Press the mode button until the symbol of a water drop appears. In dehumidification mode, the fan runs at low speed and the unit removes excess moisture without overcooling the room. Keep the drain hose properly connected to prevent water collection.
What do the error codes on the display mean?
Error codes alert you to sensor, communication or compressor issues. Switch the unit off, wait a few minutes, and restart it. If the code stays on the display, note the code and contact the Vivax authorized service center for diagnosis.
How do I clean the remote control and unit surfaces?
Use a soft, dry cloth to wipe the indoor unit and remote control. Do not use water, aggressive cleaners or solvents. Clean the remote control battery contacts occasionally and remove the batteries if the unit will not be used for a long time.
What maintenance should be performed at the end of the season?
After the cooling season, clean all filters, let the unit dry in fan mode for a few hours, and turn off its circuit breaker. Also check the drain pan and remove any dust from the outdoor coil. A professional check every year is recommended.

User questions about ACP-07CH21AEMI/I Vivax

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual ACP-07CH21AEMI/I - Vivax and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ACP-07CH21AEMI/I by Vivax.

USER MANUAL ACP-07CH21AEMI/I Vivax

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Vivax

Model : ACP-07CH21AEMI/I

Category : Air conditioner