GIMA

OXY-9 - Measuring equipment GIMA - Free user manual and instructions

Find the device manual for free OXY-9 GIMA in PDF.

📄 20 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice GIMA OXY-9 - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Fingertip pulse oximeter
Brand GIMA
Model OXY-9
Category Measuring equipment
Display Digital LED display with one-touch operation
Measurement Parameters SpO2 and pulse rate
SpO2 Measuring Range 70% to 99%
SpO2 Accuracy ±2% on the 80-99% range
Pulse Rate Measuring Range 30 to 250 bpm
Pulse Rate Accuracy ±2 bpm
Sensor Type Red and infrared dual-wavelength optical sensor
Finger Size Suitable for finger thickness from 8 to 25 mm
Power Supply 2 × AAA alkaline batteries
Battery Life Approximately 30 hours of continuous use
Dimensions Approximately 58 × 32 × 32 mm
Weight Approximately 55 g without batteries
Main Functions Real-time SpO2 and pulse rate display, pulse bar graph, auto power-off
Clinical Use Spot-check monitoring for adults in home, clinic and hospital settings
Safety Features Low battery indicator, automatic power-off when finger removed, medical-grade device
Cleaning and Maintenance Wipe the exterior with a soft dry cloth or 70% isopropyl alcohol; do not immerse in liquid
Storage Conditions Store in a dry, clean place at 10-35°C; avoid direct sunlight and strong magnetic fields
Spare Parts and Repairability Replaceable batteries and silicone finger pad; no user-serviceable internal parts
General Information Includes lanyard and carrying case; instruction manual available in 20 pages

Frequently Asked Questions - OXY-9 GIMA

What is the GIMA OXY-9 used for?
The GIMA OXY-9 is a fingertip pulse oximeter used to measure blood oxygen saturation (SpO2) and pulse rate. It is designed for spot-check monitoring in adults and is suitable for home, clinical and hospital settings.
Which finger should I place in the OXY-9?
Use your middle or index finger. Make sure the finger is clean, warm and free of nail polish or acrylic nails. Push the finger fully into the soft silicone chamber until the fingertip touches the end, then keep your hand steady during measurement.
How do I turn on the OXY-9?
Simply insert two AAA batteries and place your finger into the chamber. The device automatically lights up and starts measuring. When you remove your finger, it will shut off automatically after a few seconds to save power.
What are normal SpO2 and pulse rate values?
A normal SpO2 reading is generally 95% to 100% for healthy adults at sea level. Normal resting pulse rate is 60 to 100 bpm, although athletes may have lower values. Consult a healthcare professional if your readings fall outside these ranges.
How do I clean and maintain the OXY-9?
Use a soft dry cloth slightly dampened with water or 70% isopropyl alcohol to wipe the exterior. Do not let liquid enter the openings and never immerse the device. Clean the silicone finger pad regularly to avoid contamination.
Why is my reading unstable or inaccurate?
Readings can be affected by excessive movement, cold hands, nail polish, bright ambient light or an improperly sized finger. Warm your hands, remain still, and remove nail polish before measuring to get a stable result.
Can the OXY-9 be used for continuous monitoring?
The OXY-9 is intended for spot-check measurements rather than continuous monitoring. It is not a replacement for professional medical equipment and should not be used for prolonged unattended monitoring without doctor supervision.
How long do the batteries last?
The device runs on two AAA alkaline batteries, which typically provide up to 30 hours of continuous measurement depending on usage and battery quality. When the low-battery indicator appears, replace both batteries promptly.
Does the OXY-9 have alarms?
The device does not replace diagnostic alarms. It offers a display of pulse bar graph and low battery indication, but alarming functions may be limited. If you need audible alarms for critical monitoring, choose a monitor designed for continuous use.
Is the OXY-9 suitable for children or infants?
The OXY-9 is designed for adults. It is not suitable for newborns or infants because the finger is likely too small for proper sensor contact. For children, use a paediatric pulse oximeter under medical guidance.

User questions about OXY-9 GIMA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual OXY-9 - GIMA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OXY-9 by GIMA.

USER MANUAL OXY-9 GIMA

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GIMA

Model : OXY-9

Category : Measuring equipment