Galaxy VS GVSOPT027 - Inverter APC - Free user manual and instructions
Find the device manual for free Galaxy VS GVSOPT027 APC in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Three-phase online double-conversion UPS |
| Brand | APC |
| Model | Galaxy VS GVSOPT027 |
| Topology | Double conversion online (VFI SS 111) |
| Power Capacity | Scalable from 30 to 100 kVA |
| Output Voltage | 380 / 400 / 415 V 3-phase |
| Input Voltage | 380 / 400 / 415 V 3-phase |
| Frequency | 50/60 Hz auto-sensing |
| Efficiency | Up to 97% in ECO mode |
| Waveform | Pure sine wave |
| Display | Color touch-screen graphical display |
| Communication | USB, RS-232, Ethernet (optional Network Management Card) |
| Battery Type | Sealed maintenance-free lead-acid (internal or external) |
| Battery Management | Intelligent ABM with temperature compensation |
| Cooling | Forced air with variable speed fans |
| Protection | Surge protection, short circuit, overload |
| Operating Temperature | 0°C to 40°C |
| Relative Humidity | 0-95% non-condensing |
| Protection Rating | IP20 (standard) |
| Dimensions (HxWxD) | 1400 x 600 x 850 mm (typical for 30 kVA) |
| Weight | Approx. 230 kg (typical for 30 kVA) |
| Certifications | CE, IEC 62040-3 |
Frequently Asked Questions - Galaxy VS GVSOPT027 APC
How do I start the Galaxy VS UPS?
To start the UPS, first ensure the input breaker is closed and the battery is connected. Then press the ON button on the front panel for at least 2 seconds. The UPS will perform a self-test and switch to inverter mode. Refer to the user manual for detailed startup procedures.
What is the recommended battery maintenance schedule?
For optimal performance, check the battery terminals every three months for corrosion and torque. Test the battery under load every six months. Replace the battery every 3 to 5 years depending on usage and ambient temperature. The UPS ABM technology automatically extends battery life.
Can I monitor the UPS remotely?
Yes, the Galaxy VS can be monitored remotely using an optional Network Management Card (NMC). This enables web-based monitoring, SNMP traps, and email alerts. You can also connect via USB or RS-232 for local monitoring with APC PowerChute software.
What is the typical backup time?
The backup time depends on the connected load and the battery configuration. With a typical 30 kVA load and an internal battery cabinet, you can expect around 5 to 15 minutes. For extended runtime, external battery cabinets can be added to meet your requirements.
How do I replace the battery?
The Galaxy VS is designed for hot-swappable battery modules. Remove the protective cover, slide out the old battery module, and insert a new one. Ensure the UPS is in bypass mode before replacing the battery to avoid disrupting the load. Always use APC-approved replacement batteries.
Can multiple Galaxy VS units be paralleled for redundancy?
Yes, the Galaxy VS supports parallel configuration for capacity or redundancy. Up to 8 units can be connected in parallel using the optional parallel kit. This provides N+1 redundancy and higher availability. Proper installation and synchronization are critical for safe parallel operation.
What regular maintenance is required?
Regular maintenance includes checking air filters and cooling fans for dust, inspecting battery connections, and verifying ventilation. It is recommended to have a preventive maintenance visit by an APC-trained technician every 12 months. This ensures the UPS operates reliably and meets safety standards.
Is the UPS compatible with a generator?
Yes, the Galaxy VS is compatible with standard AC generators. However, the generator should be properly sized and its output frequency and voltage must be stable. The UPS can adjust to a wide input frequency range, but a fuel-fed generator may require additional tuning for optimal performance.
What safety precautions should I take during installation?
Installation must be performed by qualified electricians and follow local electrical codes. Ensure the UPS is grounded, the input and output circuits are properly protected, and the battery connections are isolated. Maintain adequate clearance for ventilation and ensure the floor can support the total weight.
How do I shut down the UPS safely?
To shut down the UPS, press the OFF button on the front panel for at least 2 seconds. The UPS will transfer the load to bypass (if available) or shut down. If you need to disconnect power entirely, open the input breaker and turn off the battery disconnect switch. Follow the user manual for emergency shutdown procedures.
User questions about Galaxy VS GVSOPT027 APC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Inverter in PDF format for free! Find your manual Galaxy VS GVSOPT027 - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Galaxy VS GVSOPT027 by APC.