Brand APC
Model G55TD6080K2
Product Type Uninterruptible Power Supply (UPS) / Inverter
Technology Online double conversion
Rated Power 60 kVA / 48 kW
Input Voltage 400 V three-phase
Output Voltage 400 V three-phase
Frequency 50/60 Hz auto-sensing
Output Waveform Pure sine wave
Transfer Time 0 ms (online)
Battery Type Sealed lead-acid, maintenance-free
Dimensions (W x D x H) 600 x 800 x 1400 mm
Weight 280 kg
Operating Temperature 0°C to 40°C
Humidity 0-95% non-condensing
Cooling Forced ventilation with variable speed fans
Protection Overload, short-circuit, surge protection
Display LCD panel with status indicators
Communication RS232, USB, and SNMP slot
Certifications CE, ISO 9001
Maintenance Periodic battery and air filter replacement
Safety Automatic bypass and emergency power-off
Repairability Modular design, accessible components
Warranty 1 year onsite

Frequently Asked Questions - G55TD6080K2 APC

What is the battery runtime for this UPS at full load?
The exact runtime depends on the number and capacity of battery modules. As a general estimate, a 60 kVA UPS provides 5-10 minutes at full load with standard battery configuration, and longer with additional battery cabinets.
Can this UPS be mounted in a standard server rack?
No, the G55TD6080K2 is a floor-standing tower UPS designed for data centers and industrial environments. Its dimensions (600 x 800 x 1400 mm) require dedicated space on the floor, not a rack.
How do I replace the batteries?
The battery modules are hot-swappable, meaning they can be replaced without shutting down the UPS. Open the front panel, disconnect the battery connector, and slide out the old module. Insert the new one and reconnect. Always follow the safety instructions in the manual.
What is the recommended maintenance schedule?
Perform a monthly inspection of the display and ventilation, check for dust and blockages. Every 6-12 months, test the batteries and replace them if the runtime drops below 80% of original. Replace the air filters annually or more often in dusty environments.
Does this UPS have a maintenance bypass?
Yes, it includes an internal maintenance bypass that allows you to power the connected equipment directly from the mains while servicing the UPS without interrupting the load.
Can I connect a generator to the input?
Yes, the UPS can operate with a generator as its input power source. Ensure the generator output is stable and within the input voltage/frequency range. It is recommended to use a generator with sufficient power rating (at least 1.5 times the UPS rating) to handle startup transients.
What communication interfaces are available for monitoring?
The UPS comes with RS232 and USB ports for local monitoring, and a SmartSlot for optional SNMP network management cards. APC's PowerChute software is included for automatic shutdown and monitoring.
Is the output waveform truly pure sine wave?
Yes, thanks to online double conversion technology, the UPS always delivers a pure sine wave output, ensuring compatibility with sensitive electronic equipment and optimal battery performance.
How do I install the UPS?
Installation should be performed by qualified personnel. The UPS requires a dedicated power circuit, adequate ventilation, and a stable floor. Connect the input power, then the battery modules, and finally the load. Follow the step-by-step instructions in the manual for initial startup and configuration.
What safety certifications does this UPS have?
The UPS is CE certified and complies with international standards for safety and electromagnetic compatibility, including IEC 62040-1 and IEC 62040-2. It also features overload and short-circuit protection for safe operation.

User questions about G55TD6080K2 APC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Inverter in PDF format for free! Find your manual G55TD6080K2 - APC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. G55TD6080K2 by APC.

USER MANUAL G55TD6080K2 APC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : APC

Model : G55TD6080K2

Category : Inverter