Sanwa

PDR302 - Measurement Sanwa - Free user manual and instructions

Find the device manual for free PDR302 Sanwa in PDF.

📄 13 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Sanwa PDR302 - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Brand Sanwa
Model PDR302
Product Type Digital Multimeter
Category Measurement
Display 3.5-digit LCD with backlight
DC Voltage 200 mV – 500 V
AC Voltage 200 V – 500 V
DC Current 200 µA – 10 A
Resistance 200 Ω – 2 MΩ
Continuity Test Buzzer under 50 Ω
Diode Test Yes, red LED indicator
Power Supply 1.5 V AAA battery × 2
Dimensions 70 × 110 × 20 mm
Weight Approx. 120 g (including battery)
Safety Rating CAT II 500 V, CE compliant
Maintenance Clean with dry cloth; avoid moisture
Spare Parts Only test leads and battery are replaceable
Repairability No user-serviceable parts; contact qualified service center
Included Accessories Test leads, 2 AAA batteries, user manual

Frequently Asked Questions - PDR302 Sanwa

How do I measure DC voltage?
Set the rotary switch to DCV, connect the red lead to the VΩmA jack and the black lead to COM, then touch the probes to the circuit. Read the value on the LCD.
How do I use the continuity buzzer?
Turn the dial to the continuity position, insert the leads, and touch the probes together. The buzzer sounds if the resistance is below about 50Ω.
What does the battery symbol mean?
It indicates low battery. Replace the batteries promptly to avoid incorrect measurements.
How to replace the batteries?
Remove the battery cover, replace both AAA batteries with new ones, ensuring correct polarity, and close the cover.
Can I measure AC voltage safely?
Yes, but never exceed 500V. Ensure the function switch is at ACV and the leads are correctly inserted. Use insulated gloves in live circuits.
Why does the display show "1"?
This indicates overrange. Select a higher range or check the input level. The input is beyond the selected measuring range.
How do I measure resistance?
Switch to Ω mode, connect the resistor to the test leads, and read the value. For in-circuit resistance, disconnect power and discharge capacitors first.
How should I clean the device?
Wipe the case with a soft, dry cloth. Do not use solvents or abrasive cleaners. Keep the input jacks clean.
What are the safety precautions?
Never use the meter on circuits above CAT II 500V, don't measure with wet hands, and always check the leads for damage before use.
How do I store the meter?
Turn off the meter, remove the batteries if not in use for long periods, and store in a dry, cool place.

User questions about PDR302 Sanwa

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual PDR302 - Sanwa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PDR302 by Sanwa.

USER MANUAL PDR302 Sanwa

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Sanwa

Model : PDR302

Category : Measurement