Product Type Arc Fault Detection Device (AFDD)
Model AC-AFDDC-015
Brand Mach Power
Rated Current 15 A
Rated Voltage 230 V AC
Frequency 50 Hz
Breaking Capacity 6 kA
Trip Curve Type C
Number of Poles 1P
Mounting DIN rail (35 mm)
Width 1 module (18 mm)
Height 80 mm
Depth 70 mm
Weight 0.2 kg
Operating Temperature -25°C to +55°C
Storage Temperature -40°C to +70°C
Protection Degree IP20
Connection Capacity 0.5 to 25 mm²
Standards IEC 62606
Functions Arc fault detection, overcurrent protection, short-circuit protection
Indication LED indicator for arc fault status
Test Button Yes, for manual testing
Maintenance Periodic testing recommended; keep clean and dry
Safety Complies with electrical safety standards; reduces risk of electrical fires
Repairability Modular design; replace unit if malfunctioning

Frequently Asked Questions - AC-AFDDC-015 Mach Power

What is an Arc Fault Detection Device (AFDD) and why do I need it?
An AFDD is a protective device designed to detect dangerous arc faults in electrical circuits and disconnect the supply to prevent fires. It is recommended for final circuits in residential and commercial installations.
What is the rated current of the AC-AFDDC-015 and what applications is it suitable for?
The device has a rated current of 15 A and is suitable for lighting and socket circuits with a nominal current up to 15 A, such as bedrooms, living rooms, and other standard outlets.
How do I install the AC-AFDDC-015 on a DIN rail?
To install, simply clip the device onto a 35 mm DIN rail. Ensure it snaps securely into place. Connect the incoming line to the top terminal and the outgoing circuit to the bottom terminal, following the wiring diagram in the manual.
How do I test the device to ensure it works correctly?
From your instructions, press the test button monthly to verify that the device trips correctly. The device should switch to the off position when the button is pressed. If it doesn't trip, the device may be faulty and should be replaced.
What does the LED indicator on the device mean?
The LED indicator provides status information. A green light typically indicates normal operation, while a red or flashing light may indicate an arc fault, a trip condition, or a hardware fault. Refer to the manual for specific patterns.
Can I use this device for both overcurrent protection and arc fault protection?
Yes, the AC-AFDDC-015 combines arc fault detection with conventional overcurrent and short-circuit protection, acting as a dual-function breaker. It eliminates the need for a separate MCB in most installations.
What maintenance is required for the device?
Maintenance is minimal. Keep the device clean and dry, and perform a monthly test using the test button. Avoid touching the terminals when the circuit is live.
What should I do if the device trips frequently?
Frequent tripping may indicate a genuine arc fault or overload in the circuit. Check connected appliances and wiring for damage. If the problem persists after removing suspicious loads, consult a qualified electrician.
Is the AC-AFDDC-015 compatible with other circuit breakers?
Yes, the device is designed for modular DIN rail enclosures and can be installed alongside other modular protection devices, as long as the combined ratings and space factors are respected.
What safety standards does this device comply with?
The AC-AFDDC-015 complies with IEC 62606, the international standard for arc fault detection devices, and meets the requirements for CE marking, ensuring safe operation.

User questions about AC-AFDDC-015 Mach Power

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual AC-AFDDC-015 - Mach Power and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AC-AFDDC-015 by Mach Power.

USER MANUAL AC-AFDDC-015 Mach Power

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Mach Power

Model : AC-AFDDC-015

Category : Uncategorized