CPH 0006 A - Fire alarm system BOSCH - Free user manual and instructions
Find the device manual for free CPH 0006 A BOSCH in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Fire Alarm Control Panel |
| Brand | Bosch |
| Model | CPH 0006 A |
| Zones | 6 conventional zones |
| Mounting | Wall-mounted |
| Power Supply | 230 V AC, 50/60 Hz, 60 W |
| Battery Backup | 24 V DC, 7 Ah sealed lead-acid |
| Display | Backlit LCD, 2x16 characters |
| Controls | Membrane keypad with indicators |
| Operating Temperature | -10 °C to 50 °C |
| Protection Rating | IP30 |
| Dimensions | 300 x 240 x 80 mm |
| Weight | 1.6 kg |
| Outputs | 2 open-collector outputs, 1 relay |
| Communication | RS-485 bus, Ethernet option |
| Compliance | EN54-2, EN54-4, CE, VdS |
| Programming | On-site via keypad or remote software |
| Maintenance | Annual test, clean dust from enclosure |
| Spare Parts | Battery, fuses, PCB, keypad |
| Documentation | Free PDF manual available |
Frequently Asked Questions - CPH 0006 A BOSCH
How do I disarm the alarm after a fire event?
To silence the alarm, press the SILENCE key on the keypad. The system will enter a silenced state while the alarm condition is still active. Press RESET after the fire is extinguished to clear the alarm and reset the panel.
How can I test the fire detection system?
Perform a walk test by placing the panel into test mode. Activate each detector with test spray or by pushing the test button. The panel should show a zone alarm and the buzzer should sound. Complete the test by resetting the system.
What should I do if the panel shows a fault?
Check the fault message on the LCD display. Common faults include a removed detector, short circuit, or battery failure. Correct the fault condition and press RESET to clear the fault.
How do I replace the backup battery?
Disconnect the mains power, open the enclosure, and unplug the battery connectors. Replace the 12 V 7 Ah battery (two in series for 24 V) with identical specifications. Reconnect, close the enclosure, and restore power. Dispose of the old battery properly.
How do I program the zone configuration?
Enter programming mode by entering your installer code and pressing the PROG key. Navigate using the arrow keys and followed the on-screen prompts to assign zones, set detector types, and configure outputs. Exit programming mode and save changes.
How many detectors can I connect per zone?
Each conventional zone supports up to 32 detectors with a maximum cable resistance of 50 Ω. The total current draw must not exceed 5 mA per zone for powered detectors.
Can I expand the system with more zones?
Yes, the CPH 0006 A can be expanded to 16 zones by adding compatible zone expansion modules connected to the RS-485 bus. Contact a licensed installer for expansion options.
How do I adjust the system date and time?
Enter the user menu with your user code, select DATE/TIME, and use the arrow keys to set the current values. Press OK to confirm. The time is maintained during a power outage by the battery.
What maintenance tasks are required regularly?
Regularly clean the exterior with a dry cloth, check the internal battery voltage quarterly, and perform a functional test of every detector at least annually. Keep a maintenance log in the panel enclosure.
How do I obtain the full installation manual?
The full manual is available as a free PDF download on notice-facile.com or the Bosch website. It contains installation instructions, wiring diagrams, and troubleshooting guidance.