BOSCH

CPH 0006 A - Fire alarm system BOSCH - Free user manual and instructions

Find the device manual for free CPH 0006 A BOSCH in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice BOSCH CPH 0006 A - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Fire Alarm Control Panel
Brand Bosch
Model CPH 0006 A
Zones 6 conventional zones
Mounting Wall-mounted
Power Supply 230 V AC, 50/60 Hz, 60 W
Battery Backup 24 V DC, 7 Ah sealed lead-acid
Display Backlit LCD, 2x16 characters
Controls Membrane keypad with indicators
Operating Temperature -10 °C to 50 °C
Protection Rating IP30
Dimensions 300 x 240 x 80 mm
Weight 1.6 kg
Outputs 2 open-collector outputs, 1 relay
Communication RS-485 bus, Ethernet option
Compliance EN54-2, EN54-4, CE, VdS
Programming On-site via keypad or remote software
Maintenance Annual test, clean dust from enclosure
Spare Parts Battery, fuses, PCB, keypad
Documentation Free PDF manual available

Frequently Asked Questions - CPH 0006 A BOSCH

How do I disarm the alarm after a fire event?
To silence the alarm, press the SILENCE key on the keypad. The system will enter a silenced state while the alarm condition is still active. Press RESET after the fire is extinguished to clear the alarm and reset the panel.
How can I test the fire detection system?
Perform a walk test by placing the panel into test mode. Activate each detector with test spray or by pushing the test button. The panel should show a zone alarm and the buzzer should sound. Complete the test by resetting the system.
What should I do if the panel shows a fault?
Check the fault message on the LCD display. Common faults include a removed detector, short circuit, or battery failure. Correct the fault condition and press RESET to clear the fault.
How do I replace the backup battery?
Disconnect the mains power, open the enclosure, and unplug the battery connectors. Replace the 12 V 7 Ah battery (two in series for 24 V) with identical specifications. Reconnect, close the enclosure, and restore power. Dispose of the old battery properly.
How do I program the zone configuration?
Enter programming mode by entering your installer code and pressing the PROG key. Navigate using the arrow keys and followed the on-screen prompts to assign zones, set detector types, and configure outputs. Exit programming mode and save changes.
How many detectors can I connect per zone?
Each conventional zone supports up to 32 detectors with a maximum cable resistance of 50 Ω. The total current draw must not exceed 5 mA per zone for powered detectors.
Can I expand the system with more zones?
Yes, the CPH 0006 A can be expanded to 16 zones by adding compatible zone expansion modules connected to the RS-485 bus. Contact a licensed installer for expansion options.
How do I adjust the system date and time?
Enter the user menu with your user code, select DATE/TIME, and use the arrow keys to set the current values. Press OK to confirm. The time is maintained during a power outage by the battery.
What maintenance tasks are required regularly?
Regularly clean the exterior with a dry cloth, check the internal battery voltage quarterly, and perform a functional test of every detector at least annually. Keep a maintenance log in the panel enclosure.
How do I obtain the full installation manual?
The full manual is available as a free PDF download on notice-facile.com or the Bosch website. It contains installation instructions, wiring diagrams, and troubleshooting guidance.

User questions about CPH 0006 A BOSCH

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fire alarm system in PDF format for free! Find your manual CPH 0006 A - BOSCH and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPH 0006 A by BOSCH.

USER MANUAL CPH 0006 A BOSCH

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BOSCH

Model : CPH 0006 A

Category : Fire alarm system