Type Portable Air Conditioner
Brand Honeywell
Model MN10CHESBB
Cooling Capacity 10,000 BTU (ASHRAE) / 6,000 BTU (DOE)
Heating Capacity 9,000 BTU
Coverage Area Up to 300 sq ft
Power Supply 115V, 60Hz
Power Consumption (Cooling) 950 W
Power Consumption (Heating) 850 W
Current 8.5 A
Dehumidification Capacity 1.5 pints/hour
Airflow 200 CFM
Noise Level 55 dB (low speed: 50 dB)
Refrigerant R32
Dimensions (W x D x H) 18.5 x 17.5 x 29.5 inches
Weight 72 lbs
Modes Cool, Heat, Fan, Dehumidify
Control Type Digital display with remote control
Special Features 24-hour timer, auto swing louver, caster wheels, washable filter
Installation Window kit included for easy installation
Maintenance Washable pre-filter and easy access to internal components
Safety Features Overheat protection and restart delay
Certifications ETL listed

Frequently Asked Questions - MN10CHESBB HONEYWELL

How do I install the exhaust hose and window kit?
The exhaust hose and window kit are essential for venting hot air outside. Attach the hose to the exhaust opening on the back of the unit, then extend the hose to fit the window kit. Slide the included window panels to match your window width and secure them in place. Make sure the hose is as straight as possible for optimal airflow. Full step-by-step instructions are in the manual.
What is the difference between BTU (ASHRAE) and BTU (DOE)?
BTU (ASHRAE) is the older standard, measured in cooling capacity at standard conditions. BTU (DOE) is the updated Department of Energy standard that accounts for more realistic usage. The DOE rating is typically lower. This unit provides 10,000 BTU (ASHRAE) / 6,000 BTU (DOE), meaning it effectively cools a room up to 300 sq ft.
How often should I clean the air filter?
For optimal performance, clean the air filter every two weeks or when the "Clean Filter" indicator lights up. Remove the filter by pulling it out from the rear grille, wash it with lukewarm water and mild detergent, let it dry completely, and reattach it. Regular cleaning prevents dust buildup and maintains airflow efficiency.
Can I use an extension cord?
It is not recommended. This air conditioner draws high power (up to 950W), and using an extension cord may cause overheating or voltage drop. Always plug the unit directly into a dedicated outlet. If an extension cord is unavoidable, use a heavy-duty 14-gauge cord rated for at least 15 amps, and keep it as short as possible.
How do I set the 24-hour timer?
Press the Timer button on the control panel or remote. Use the + / - buttons to set the desired time (from 1 to 24 hours). The unit will automatically turn on or off after the set period, depending on the current mode. Refer to the manual for specific on/off programming details.
What should I do if the unit is not cooling properly?
First, check that the exhaust hose is properly vented and not blocked. Ensure all doors and windows are closed, and the air filter is clean. If the room is very large or has high heat sources, the unit may be undersized. Also, confirm that the cooling mode is set and the temperature is lower than the room temperature. If issue persists, reset the unit by unplugging for 10 minutes.
How often should I drain the water?
The unit uses a self-evaporating system that recycles condensation, but during high humidity, some water may need manual draining. If the "Full Tank" indicator lights up, remove the drain plug at the back or bottom and let the water flow into a pan. Alternatively, you can connect a drain hose for continuous drainage.
How do I switch between cool and heat modes?
Press the Mode button repeatedly to cycle through Cool, Heat, Fan, and Dehumidify modes. The display will show the selected mode. In Heat mode, the unit works as a heater to warm the room. Make sure to set the desired temperature above the current room temperature for heating.
What is the recommended room size for this unit?
The cooling capacity of 10,000 BTU (ASHRAE) / 6,000 BTU (DOE) is effective for rooms up to 300 sq ft. For the heating function, it covers a similar area. We recommend a room size between 250-300 sq ft for optimal performance.
How should I store the unit during the off-season?
Before storage, run the unit on Fan mode for half a day to dry out the internal parts. Drain any remaining water, remove the exhaust hose, and clean the filter. Wrap the power cord around the built-in hooks and keep the unit in a dry place. Cover with a plastic or cloth to prevent dust accumulation.

User questions about MN10CHESBB HONEYWELL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.