Product Type Wedge Anchor
Thread Size M12
Overall Length 100 mm
Embedment Depth 75 mm
Drill Hole Diameter 14 mm
Material Carbon Steel, Zinc Plated
Weight per Piece 0.12 kg
Installation Method Torque-controlled expansion
Base Material Normal weight concrete (C20/25 to C50/60)
Load Capacity (Tension) 10.5 kN (for M12 in C20/25)
Load Capacity (Shear) 14.6 kN (for M12 in C20/25)
Approvals ETA (European Technical Assessment)
Fire Resistance R30 to R120 (depending on concrete cover)
Function Securely fasten structural elements to concrete
Maintenance Inspect for corrosion periodically; keep dry
Safety Precautions Do not use in cracked concrete without specific approval; follow torque settings
Spare Parts Replacement nuts and washers available separately
Repairability Non-repairable; replace if damaged
Environmental Resistance Suitable for dry, indoor environments; not for outdoor exposure without coating
Packaging Quantity 50 pieces per box

Frequently Asked Questions - HDA-PF HILTI

What is a Hilti HDA-PF wedge anchor used for?
The Hilti HDA-PF is a heavy-duty expansion anchor designed for fastening structural elements to concrete, such as steel columns, machinery, and safety barriers.
What are the required drill bit sizes for M12 HDA-PF?
For M12 HDA-PF, use a drill bit diameter of 14 mm and a minimum drilling depth of 82 mm (embedment depth 75 mm).
Can the HDA-PF be used in cracked concrete?
Standard HDA-PF anchors are not approved for cracked concrete. Use the Cracked Concrete variant (HDA-PFC) if required.
What is the torque setting for installation?
The recommended installation torque for M12 HDA-PF is 60 Nm. Over-torquing may damage the anchor.
How do I remove an installed HDA-PF anchor?
HDA-PF anchors are not designed for removal. If removal is necessary, cut off the exposed stud and drive it into the hole, then fill the surface.
What is the minimum spacing between anchors?
Minimum spacing for M12 HDA-PF is 150 mm. Edge distance should be at least 100 mm from the concrete edge.
Is the HDA-PF suitable for outdoor use?
Standard zinc-plated anchors are for indoor use only. For outdoor or corrosive environments, use the stainless steel version (HDA-PF A4).
What is the static load capacity of M12 HDA-PF?
In C20/25 concrete, the characteristic tension resistance is 10.5 kN and shear resistance is 14.6 kN (allowable load depends on safety factors).
How do I check if the anchor is properly set?
After torquing, verify that the expansion clip is flush with the nut and that the anchor does not rotate freely in the hole.
Can I reuse an HDA-PF anchor?
No, wedge anchors are single-use because the expansion clip deforms permanently. Always use a new anchor for each installation.

User questions about HDA-PF HILTI

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual HDA-PF - HILTI and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HDA-PF by HILTI.

USER MANUAL HDA-PF HILTI

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HILTI

Model : HDA-PF

Category : Uncategorized