HILTI

CFS-BL - Uncategorized HILTI - Free user manual and instructions

Find the device manual for free CFS-BL HILTI in PDF.

📄 1 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HILTI CFS-BL - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Firestop Collar
Model CFS-BL
Brand Hilti
Application Fire protection for plastic pipes
Pipe Diameter Range 32 mm to 160 mm (varies by variant)
Material Steel housing with intumescent insert
Fire Resistance Up to 120 minutes (EI 120)
Installation Method Snap-on around pipe, fixed with brackets
Weight (typical) 0.5 kg (for 110 mm variant)
Dimensions (L x W x H) Approx. 150 x 150 x 60 mm (for 110 mm variant)
Certification CE marked, ETA (European Technical Assessment)
Operating Temperature -20 °C to 60 °C
Intumescent Material Graphite-based, expands when heated
Maintenance None required; inspect regularly for damage
Cleaning Wipe with a dry cloth; do not use solvents
Safety Precautions Install per manufacturer instructions; ensure proper fit
Spare Parts Not available; replace entire unit if damaged
Repairability Not repairable; replace if activated or damaged
Warranty Refer to Hilti terms and conditions
Intended Use Penetration sealing in fire-rated walls and floors

Frequently Asked Questions - CFS-BL HILTI

What is the Hilti CFS-BL used for?
The Hilti CFS-BL is a firestop collar designed to maintain the fire resistance of walls and floors where plastic pipes pass through.
How does the CFS-BL work?
It contains an intumescent material that expands when exposed to heat, sealing off the pipe opening and preventing the spread of fire and smoke.
What pipe diameters does the CFS-BL fit?
The CFS-BL is available in various sizes to fit pipe diameters from 32 mm to 160 mm. Check the specific variant for your pipe size.
What fire rating does the CFS-BL provide?
Depending on the installation and wall/floor type, the CFS-BL can provide up to 120 minutes of fire resistance (EI 120).
How do I install the CFS-BL?
Snap the collar around the plastic pipe and secure it with the provided brackets. Ensure a tight fit and that the collar is centered on the penetration.
Can the CFS-BL be used in walls and floors?
Yes, it is suitable for both fire-rated walls and floors, provided the installation follows Hilti guidelines.
Does the CFS-BL require maintenance?
No regular maintenance is required, but periodic inspections should be carried out to ensure no damage has occurred.
What if the CFS-BL has been activated?
If the intumescent material has expanded (e.g., after a fire), the entire collar must be replaced as it is single-use.
Is the CFS-BL compatible with all plastic pipes?
It is designed for standard plastic pipes like PVC, PE, and PP. Ensure the pipe material and diameter are compatible.
Where can I find the installation manual?
The user manual is available for free download on notice-facile.com. You can also contact Hilti directly for technical support.

User questions about CFS-BL HILTI

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual CFS-BL - HILTI and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CFS-BL by HILTI.

USER MANUAL CFS-BL HILTI

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HILTI

Model : CFS-BL

Category : Uncategorized