| Brand | Maruyama |
| Model | MP8010EH |
| Product Type | Water Pump |
| Engine Type | Gasoline, 4-stroke |
| Displacement | 196 cc |
| Max Power | 6.5 hp |
| Fuel Tank Capacity | 3.6 L |
| Max Flow Rate | 150 L/min |
| Max Head | 35 m |
| Suction Lift | 8 m |
| Inlet/Outlet Diameter | 2 inch (50 mm) |
| Dimensions (L x W x H) | 510 x 410 x 450 mm |
| Dry Weight | 26 kg |
| Start Method | Recoil start |
| Priming | Manual priming via fill port |
| Cooling System | Air cooled |
| Oil Capacity | 0.6 L (SAE 10W-30) |
| Maintenance Schedule | Check oil before each use; change oil every 50 hours |
| Safety Features | Engine kill switch, hot surface guards, spark arrestor |
| Warranty | 2 years limited |
Frequently Asked Questions - MP8010EH Maruyama
How do I start the Maruyama MP8010EH pump?
Ensure the pump is on a level surface, fuel tank is filled with fresh unleaded gasoline, and engine oil is at proper level. Turn the fuel valve to ON, set choke to CLOSED if cold, pull the recoil starter rope firmly until the engine starts, then gradually open the choke.
What type of oil should I use?
Use a high-quality 4-stroke engine oil with viscosity SAE 10W-30. The oil capacity is 0.6 liters. Check oil level before each use and change every 50 hours of operation.
How do I prime the pump before use?
Remove the priming plug or fill port cap on the pump housing. Pour water into the housing until it is full, then replace the cap. This primes the pump and ensures proper suction.
What is the maximum suction lift?
The maximum suction lift is 8 meters (26 feet) from water source to pump. For best performance, keep suction hose as short and straight as possible.
Why is my pump not producing water?
Check if the pump is primed (filled with water). Ensure suction hose is not blocked, kinked, or leaking. Verify that the strainer is clean and submerged. Also check that the discharge hose is not restricted.
Can I use an extension hose to reach farther?
Yes, but keep the total discharge hose length reasonable (typically up to 30 meters) to avoid pressure loss. Use a hose of the same diameter (2 inch) for best performance.
How often should I clean the air filter?
Clean the air filter every 25 hours of operation or more frequently in dusty conditions. Use soapy water, rinse, dry, and re-oil it lightly before reinstalling.
What safety precautions should I follow?
Always operate the pump in a well-ventilated area to avoid carbon monoxide poisoning. Keep hands away from moving parts. Use the engine kill switch to stop immediately in an emergency. Allow the engine to cool before refueling.
How do I store the pump for long periods?
Drain fuel from the tank and carburetor. Change the engine oil. Clean the pump and hoses. Store in a dry, covered location. Disconnect spark plug wire to prevent accidental starting.
Where can I find replacement parts?
Contact Maruyama authorized dealers or service centers. Common parts include oil filters, air filters, spark plugs, and pump impellers. Visit the official Maruyama website for a dealer locator.