RPT-60C - Electric meter Mean Well - Free user manual and instructions
Find the device manual for free RPT-60C Mean Well in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Type of product | Electric energy meter |
| Model | RPT-60C |
| Brand | Mean Well |
| Dimensions (H x W x D) | 72 x 72 x 65 mm |
| Weight | Approx. 200 g |
| Power supply | 85-264 VAC, 50/60 Hz |
| Measurement accuracy | Class 1 (active energy) |
| Display | LCD, 6+2 digits |
| Communication | RS485 Modbus RTU |
| Rated current (Ib) | 5 A |
| Maximum current (Imax) | 60 A |
| Voltage rating | 230/400 VAC (L-L) |
| Frequency range | 45-65 Hz |
| Operating temperature | -10°C to +55°C |
| Storage temperature | -25°C to +70°C |
| Humidity range | 0-95% RH (non-condensing) |
| Ingress protection | IP51 (front panel) |
| Mounting | Panel mount, 72x72 mm cut-out |
| Functions | Active energy (kWh), active power (kW), voltage, current, frequency, power factor |
| Maintenance & cleaning | Clean with dry cloth; no solvents. Check connections periodically. |
| Safety | Double insulation, CAT III, overvoltage protection |
| Spare parts & repairability | Contact Mean Well service; no user-serviceable parts inside. |
| General information | Conforms to IEC 62053-21, MID optional |
Frequently Asked Questions - RPT-60C Mean Well
How do I install the RPT-60C electric meter?
Mount the meter in a 72x72 mm panel cut-out. Connect the power supply (85-264 VAC) to the designated terminals. For current measurement, connect the CT or direct input as per the wiring diagram in the manual. Ensure all connections are tight and comply with local electrical codes.
What is the accuracy class of the RPT-60C?
The RPT-60C has an accuracy class of 1 for active energy measurement, meaning it meets IEC 62053-21 Class 1 requirements.
Can I read the meter remotely?
Yes, the RPT-60C features an RS485 Modbus RTU communication port. You can connect it to a data logger or building management system to read energy data remotely.
How do I reset the energy reading?
To reset the total energy reading (kWh), press and hold the 'Set' button for 3 seconds until the display flashes. Confirm the reset by pressing 'Enter'. This action cannot be undone.
What do the displayed values mean?
The LCD alternately shows active energy (kWh), active power (kW), voltage (V), current (A), frequency (Hz), and power factor (PF). Use the 'Mode' button to cycle through parameters.
Is the RPT-60C suitable for three-phase systems?
Yes, the RPT-60C is designed for both single-phase and three-phase systems (3-wire or 4-wire). It measures line-to-line voltages up to 400 VAC.
What is the maximum current the meter can handle?
The rated current (Ib) is 5 A, and the maximum continuous current (Imax) is 60 A. For higher currents, use external current transformers (CTs) with a 5 A secondary.
How do I set the communication parameters?
Access the setup menu by pressing and holding the 'Mode' and 'Set' buttons simultaneously. Navigate to the COM menu to set baud rate (default 9600), parity, and Modbus address (1-247).
What should I do if the display shows 'Err'?
An 'Err' code indicates a measurement error. Check wiring: ensure voltage and current phase sequences match, and that the neutral is connected. If persistent, contact Mean Well support.
How do I clean the meter?
Disconnect power before cleaning. Wipe the front panel with a soft, dry cloth. Do not use water, solvents, or abrasive cleaners, as they may damage the display and seals.
User questions about RPT-60C Mean Well
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Electric meter in PDF format for free! Find your manual RPT-60C - Mean Well and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RPT-60C by Mean Well.