AP9563 - Uncategorized APC - Free user manual and instructions
Find the device manual for free AP9563 APC in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Model | AP9563 |
| Brand | APC |
| Dimensions (H x W x D) | 3.5 x 17.5 x 19 inches (2U rack-mount) |
| Weight | 28 kg (61.7 lbs) |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC |
| Capacity | 1500 VA / 1000 W |
| Battery Type | Sealed lead-acid, maintenance-free |
| Battery Runtime (full load) | Approximately 7 minutes |
| Recharge Time | 3 hours to 90% capacity |
| Waveform Type | Stepped approximation to sinewave |
| Input Connector | IEC 320-C20 |
| Output Connectors | 8 x IEC 320-C13 (battery backup), 2 x IEC 320-C13 (surge only) |
| Surge Protection | Yes, 340 Joules |
| Noise Filtering | EMI/RFI filtering, 5% IEEE surge let-through |
| Operating Temperature | 0 to 40 °C (32 to 104 °F) |
| Safety Certifications | CE, UL, cUL, FCC |
| Maintenance | Clean with dry cloth; no user-serviceable parts |
| Repairability | Battery user-replaceable; other repairs by qualified personnel only |
Frequently Asked Questions - AP9563 APC
What does the APC AP9563 UPS protect against?
It protects against power outages, brownouts, surges, and sags, providing backup battery power for connected devices.
How do I replace the battery in the AP9563?
Turn off the UPS, unplug it, open the front panel, disconnect the battery cables, remove the old battery, and install a new APC RBC2 battery. Refer to the manual for detailed steps.
What is the runtime of the AP9563 at full load?
At full load (1000W), the runtime is approximately 7 minutes. At half load (500W), it extends to about 20 minutes.
Can the AP9563 be rack-mounted?
Yes, the AP9563 is designed for 2U rack-mount installation. It includes the necessary mounting hardware.
How do I clean the AP9563?
Unplug the unit and wipe the exterior with a dry cloth. Do not use liquids or aerosols.
What does the alarm on the AP9563 mean?
A continuous alarm indicates a battery or overload condition. Check the front panel LEDs for specific status.
Is the AP9563 compatible with generator power?
It is recommended to use the UPS with stable utility power. Generator output may cause frequency instability; use a generator with automatic voltage regulation if necessary.
How long does it take to recharge the battery after a power outage?
The battery recharges to 90% capacity in about 3 hours.
What should I do if the AP9563 emits smoke or a burning smell?
Immediately unplug the unit from power and disconnect all connected devices. Do not use until inspected by a qualified service technician.
Where can I find the serial number on the AP9563?
The serial number is located on the rear panel near the input power cord, on a sticker.