ACD-MFC-ISO - Uncategorized BOSCH - Free user manual and instructions
Find the device manual for free ACD-MFC-ISO BOSCH in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Bosch |
| Model | ACD-MFC-ISO |
| Product Type | Industrial Sensor/Controller |
| Dimensions (W x H x D) | 120 mm x 80 mm x 35 mm |
| Weight | 200 g |
| Power Supply | 24 V DC |
| Power Consumption | 5 W |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 70°C |
| Humidity Range | 10% to 90% RH (non-condensing) |
| Primary Functions | Measurement, Control, Communication |
| Communication Protocol | Modbus RTU (RS485) |
| Analog Output | 4-20 mA |
| Digital Inputs/Outputs | 2 DI / 2 DO |
| Display | LED indicators (Power, Status, Error) |
| Enclosure Rating | IP20 |
| Enclosure Material | ABS plastic |
| Installation | DIN rail mount |
| Maintenance | Wipe with dry cloth; no solvents |
| Safety Features | Overvoltage protection, reverse polarity protection |
| Spare Parts / Repairability | Not user-serviceable; contact Bosch support |
| Certifications | CE, ISO 9001 |
Frequently Asked Questions - ACD-MFC-ISO BOSCH
How do I install the Bosch ACD-MFC-ISO?
Mount the device on a DIN rail in a control cabinet. Ensure the power supply is 24 V DC and connections are secure. Refer to the wiring diagram in the manual.
What is the default communication settings?
The default Modbus settings are: baud rate 9600, 8 data bits, no parity, 1 stop bit, device ID 1. These can be changed via the configuration software.
How do I calibrate the sensor?
Calibration requires a known reference signal. Use the Calibration Mode in the configuration software to adjust the zero and span points. Always follow the specific calibration procedure for your application.
The device shows an error LED. What should I do?
Check the power supply (24 V DC) and wiring connections. Refer to the error code table in the manual. Common causes include overvoltage, communication timeout, or sensor fault.
Can I use this device outdoors?
No, the IP20 rating only protects against solid objects >12.5 mm. Use in a dry, indoor environment without condensation. For outdoor use, install an appropriate enclosure.
How do I connect the analog output?
Connect the 4-20 mA output to a PLC or display with input impedance ≤ 500 Ω. Ensure correct polarity: +24 V loop power is provided internally for passive devices.
What is the maximum cable length for RS485?
For reliable communication, use twisted-pair cable up to 1200 meters at 9600 baud. Terminate the bus with 120 Ω resistors at both ends.
How do I update the firmware?
Firmware updates are provided by Bosch. Use the Bosch Firmware Tool via USB interface (if available) or Modbus. Disconnect power during update.
The device is not responding. What should I check?
Verify power supply voltage, check fuse (if any), and confirm Modbus cable connections. Ensure the device address matches the master request. Reset by cycling power.
Is the device RoHS compliant?
Yes, the Bosch ACD-MFC-ISO is RoHS and REACH compliant. It does not contain hazardous substances above permitted limits.
User questions about ACD-MFC-ISO BOSCH
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual ACD-MFC-ISO - BOSCH and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ACD-MFC-ISO by BOSCH.